ARTICLE
Received 22 Oct 2012 | Accepted 26 Feb 2013 | Published 27 Mar 2013
Most bioparticles, such as red blood cells and bacteria, are non-spherical in shape. However, conventional microuidic separation devices are designed for spherical particles. This poses a challenge in designing a separation device for non-spherical bioparticles, as the smallest dimension of the bioparticle has to be considered, which increases fabrication challenges and decreases the throughput. If current methods do not take into account the shape of non-spherical bioparticles, the separation will be inefcient. Here, to address this challenge, we present a novel technique for the separation of red blood cells as a non-spherical bioparticle, using a new I-shaped pillar arrays design. It takes the shape into account and induces rotational movements, allowing us to leverage on the largest dimension, which increases its separation size. This technique has been used for 100% separation of red blood cells from blood samples in a focused stream, outperforming the conventional pillar array designs.
DOI: 10.1038/ncomms2653
Rotational separation of non-spherical bioparticles using I-shaped pillar arrays in a microuidic device
Kerwin Kwek Zeming1,*, Shashi Ranjan1,* & Yong Zhang1,2,3
1 Department of Bioengineering, Faculty of Engineering, National University of Singapore, Block EA 03-12, 9 Engineering Drive 1, Singapore 117576, Singapore.
2 Nanoscience and Nanotechnology Initiative, National University of Singapore, Block E3-05-29, 2 Engineering Drive 3, Singapore 117581, Singapore.
3 NUS Graduate School for Integrative Sciences and Engineering, Centre for Life Sciences (CeLS), National University of Singapore, 05-01 28 Medical Drive, Singapore 117456, Singapore. * These authors contributed equally to this work. Correspondence and requests for materials should be addressed toY. Z. (email: mailto:[email protected]
Web End [email protected] ).
NATURE COMMUNICATIONS | 4:1625 | DOI: 10.1038/ncomms2653 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications 1
& 2013 Macmillan Publishers Limited. All rights reserved.
ARTICLE NATURE COMMUNICATIONS | DOI: 10.1038/ncomms2653
The capacity to isolate various biological entities, such as pathogen and blood components, enables the diagnosis and detection of diseases, infections and biological
threats1,2. Traditional processes of separating these bioparticles, such as centrifugal separation, ltration, culture and isolation, involve cumbersome benchtop equipment. Advances in micromachining resulted in the development of microuidic devices, in which bioparticle separation process can now be performed at microscale, commonly known as lab-on-a-chip3. These devices potentially have an edge over traditional techniques, as it reduces human error via automation and require low sample volumes, resulting in a rapid, high-throughput, cost-efcient and reproducible separation of bioparticles4,5.
Bioparticles are separated in microuidic devices by three general principles, namely size discrimination in sieving techniques, hydrodynamic laminar ow separation and non-inertia force elds, such as dielectrophoresis, acoustic, radiation and magnetic eld58. The main separation criteria for all these methods depend on the spherical diameter of these bioparticles (that is, particles are considered as spherical)5,9. Dependence on the spherical size poses a challenge for the separation of non-spherical bioparticles. Biological entities, such as rod-shaped bacteria and disc-shaped red blood cells (RBCs), have disproportional length and width, which complicates the separation process designed for spherical particles, as the narrowest width has to be considered for the separation criteria within the design parameters of the microuidic devices.
One of the clinically relevant non-spherical bioparticles is the RBC, as its separation from plasma allows diagnosis of different diseases. RBCs are disc-shaped biconcaved cells with a diameter of B8 mm and thickness of about 2 mm. Separation techniques, such as RBC ow margination, cross-ow ltration and deterministic lateral displacement (DLD) have been used for RBC separation from whole blood1. RBC ow margination technique utilizes the difference in size and deformability of RBC and other circulating cells for the separation. The deformable RBCs migrate to the center of the uidic channels, while the larger white blood cells or smaller bioparticles, such as platelets or bacteria, migrate to the walls of the channel. Multiple RBC cell margination ow iterations have enabled purication of RBCs from bacteria and leukocytes, while malaria-affected cells were separated with an efciency of B7590%, depending on its stage of infection10,11. Hou et al.10,11 also briey mentioned that the non-spherical shape of bacteria could have contributed to the separation process, which emphasizes the impact of shape-based sorting. Cross-ow ltration techniques were also used to separate RBC and plasma where the blood sample ows within a straight channel, while the plasma or smaller particles elute out of the sample using narrow pores or channel gaps aligned perpendicular to the ow9. VanDelinder et al.12 and Crowley et al.13 both designed a cross-ow gap size of 0.5 mm to prevent
RBCs from migrating past the gaps. DLD devices have also been used to separate RBCs from blood and plasma, which allows distinct separation into separate streams1416. To effectively separate the RBCs, it is assumed to have a critical separation diameter of 2 mm to compensate for deformation or possible preferential orientation of RBCs at its thinnest dimension in the laminar ow stream. Recent developments for RBCs separation in DLD devices control the orientation of RBCs by reducing the channel depth to a minimum, allowing an increased separation diameter14,17; however, this connes the sample to a narrow channel depth, which restricts high throughput and is not necessarily effective for other non-spherical particles, such as rod-shaped or spiral-shaped bacteria. These separation techniques do not provide a comprehensive solution for the separation of non-spherical particles. Hence, to effectively separate non-spherical
biological entities for rapid medical diagnosis, new separation methods, which take into consideration the multivariate shapes of the bioparticles, are required.
Here we present a novel separation technique taking into account the shape of the particles by inducing continuous rotation of the particles. This separation principle is based on DLD, which has been established as an efcient technique for the continuous-ow separation of particles that are dependent on their spherical dimension, by using conventional cylindrical pillars1821. Accounting for the shape of particles, we hypothesize that inducing rotations of non-spherical particles will increase the effective separation size of the particles. By leveraging on the continuous rotation of a non-spherical particle, we are able to reduce the emphasis on the narrowest width and instead focus on mimicking a spherical particle based on its greatest length. From our hypothesis, we have designed a novel I-shaped pillar to induce the rotation of non-spherical particles owing in the laminar stream through our separation device shown in Fig. 1a. The pillar shape and principle is schematically explained in Fig. 1b with the example of a disc-shaped particle. The critical diameter of the particle to be separated in Fig. 1b (i) would be the smallest dimension of the particle (D1) while the rotating disc-shaped particle in Fig. 1b (ii) would have a maximum rotational diameter of D2, which is much greater than D1. The I-shaped pillar has two protrusions, which induce rotations, and a middle groove to accommodate the rotation. By inducing continuous rotation and by increasing the effective size for separation, our novel design can potentially separate the bioparticles with diverse shapes and sizes.
Some efforts have been made to change the post shape of DLD to enhance its critical separation diameter22,23. Loutherback et al.22,23 have demonstrated that by using triangular pillars, the ow prole becomes asymmetric, resulting in a reduced critical diameter as compared with conventional DLD. However, this improvement does not address the varying critical diameter of a non-spherical particle. Sugaya et al.24 have also observed that by rotating non-spherical particles at the T-junction in a hydrodynamic ltration device, separation of non-spherical particles based on its longer dimension can be achieved. However, it is limited to a single ipping event of a non-spherical particle at the T-junction, which determines the success or failure of the separation process.
Here we study the effect of novel I-shaped pillar on the continuous rotation and, hence, the separation of disc-shaped RBCs. The novelty of our project is twofold. First, we successfully separated non-spherical particles by inducing continuous rotations. Second, we present a novel design in terms of I-shaped pillar for the induction of rotations and, hence, separations of these particles in a laminar ow separation process. Our current ndings for RBCs separation could potentially separate other non-spherical particles, like pathogens, with higher-throughput and efciency, circumventing the spherical size dependency of current techniques.
ResultsRBC separation and comparison study. The novel I-shaped pillar design can induce rotations for non-spherical particles to increase the RBCs effective separation size. The term effective separation size is referred here as the critical diameter of particle needed for separation in our device. Figure 1d shows comparison of RBC separation paths between cylindrical pillars, square pillars and I-shaped pillars. All three pillar types in Fig. 1c are designed with exactly the same DLD dimensions of 10 mm gap size, pillar shift gradient of 2.86o and a maximum pillar length of 15 mm. The device was etched to B15 mm deep. We wanted to compare how the conventional cylindrical pillars fared with sharp edges of
2 NATURE COMMUNICATIONS | 4:1625 | DOI: 10.1038/ncomms2653 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications
& 2013 Macmillan Publishers Limited. All rights reserved.
NATURE COMMUNICATIONS | DOI: 10.1038/ncomms2653 ARTICLE
Fluid inlets Buffer inlets
Sample stream
Effective DLD
(i) diameter (ii)
D1 = 2 m
D2 = 8 m
Hypothesized rotational diameter
20 mm 2 mm
Sub channel 1 to 40 outlets
Fluid outlets
10 m
10 m
10 m
15 m
15 m
2.87
10 m
10 m
10 m
10 m
15 m
15 m
2.87
15 m 2.87
Direction of RBC
RBC non-separated path
RBC separation path
Secondary separation path
Figure 1 | Schematics of device designs and hypothesis. (a) The sample stream is sandwiched between two buffer streams, and the output channels are divided into 40 subchannels for quantication of the RBC separation process. White scale bar, 250 mm. The hypothesis schematics in b shows the difference between the conventional DLD pillars in (b, i) and I-shaped DLD pillars in (b, ii) with both top view and cross-section view at the bottom. Three devices of xed DLD parameters and varying shape is shown in c, namely cylindrical, square and I-shaped pillar array. Lastly, d it depicts the projected paths of RBCs, as it ows within the respective devices.
square pillars and the proposed I-shaped pillars. The overall device setup can be seen in Supplementary Fig. S1.
There are 40 output subchannels identied as channel 140 starting from left to right shown in Fig. 1a. To quantify the effect of separation, RBCs at each subchannel output is counted and is tabulated as a ratio of the total RBCs calculated. However, only channels 130 is tabulated in the graph shown in Fig. 2, as there are no RBCs owing in channels 3140 due to the buffer stream on the right side of the graph. In all three pillar types, fresh blood is infused into the device using a syringe pump at a rate of0.2 ml min 1. The buffer streams sandwich the sample stream with a ow rate of 0.5 ml min 1 each. At these ow rates, the input distribution of RBC for the sample stream spreads from channel 17 to channel 26 (see Supplementary Fig. S2). The result for output stream is shown in Fig. 2, which concurs with the schematics shown in Fig. 1d. Clearly shown are the RBC separation at the output regions with minimal RBC separation for cylindrical pillars in Fig. 2a, scattered distribution of RBC for
square pillars in Fig. 2b and highly effective and focused separation for I-shaped pillars in Fig. 2c. Three sets of video output data were acquired using the high-speed camera, and the ratio of RBCs at the output were tabulated into the graphs (Fig. 2).
RBC separation is not observed in the cylindrical pillar array for the given parameters. The nal output shown in Fig. 2a depicts the RBC output distribution ratio to be between channels 15 and 25, which do not deviate from the original sample distribution of channels 1726. The distribution peaked at B24% in channel 20. The critical diameter of the cylindrical pillars is calculated to be 3.33 mm, based on the recent DLD blood separation papers, which simplify the original formulation for critical diameter calculations (see Methods)14,16,17,19. For DLD separation to be effective, the particle to be separated has to be larger than the critical diameter. In this case, the RBCs narrowest width (2 mm)
is smaller than the critical diameter, resulting in no separation that can be seen in the distribution of RBC ratio in Fig. 2a. From
NATURE COMMUNICATIONS | 4:1625 | DOI: 10.1038/ncomms2653 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications 3
& 2013 Macmillan Publishers Limited. All rights reserved.
ARTICLE NATURE COMMUNICATIONS | DOI: 10.1038/ncomms2653
100
50
0
RBC output percentage RBC output percentage RBC output percentage
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
Output channels
Output channels
Output channels
100
50
0
100
50
0
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
Figure 2 | RBC separation at output channels. Results of the RBC separation for cylindrical pillars (a), square pillars (b) and I-shaped pillars (c). The histograms are plotted by the percentage of total RBC at the output channels. The screen capture of the output regions are shown on the right of the respective graphs. (c) Magnied region of the I-shaped DLD pillars at the output channels 15. All error bars were calculated as s.d. at individual outputs of three samples taken from three experiments. Scale bar, 250 mm.
Fig. 2b, the RBC separation in square pillar array shows a widely distributed RBC output ratio ranging from channels 1 to 26. The peak RBC output ratio is B8% at channel 20. Though 63% of the
RBC is distributed near the central regions (between channels 15 to 25), there are RBCs that deviated all the way to channel 1. Comparatively, square pillar have an effect on RBC separation as compared with cylindrical pillars with the same pillar array parameters, such as gap size (10 mm) and pillar array gradient(2.86o). It is important to note that the RBCs do rotate in the square pillar array. From Fig. 3a, we can see that the edge could have caused the RBC to ip and rotate. This could have an effect on the separation, causing a widespread of RBC distribution ratio shown in Fig. 2b. Although this result in square pillars requires further investigation, our main focus is to use it as a control for I-shaped pillars. The distinct spread and scattering of RBC distribution for square pillars show that the square pillar array has an enhanced effect on RBC separation compared with cylindrical pillars, but not effective enough to ensure an efcient separation. In contrast to square and cylindrical pillars, I-shaped pillars are extremely effective in separating RBCs. The output graph in Fig. 2c shows complete separation of RBC in channels 14, deviating away from its original RBC input distribution of channels 1526. Also, the peak distribution of B86% in channel 1 is distinctly greater than the peak distribution for square (B8%) and cylindrical pillar (B24%) array devices. The slight spread to channels 2 and 3 are due to slight overcrowding of RBC in channel 1, which spill over to the other channels. The magnied view shows a snap shot of the 100% separated RBC stream in the output channel 1 (Supplementary Movie 1). This focused stream of RBC separation clearly shows the effectiveness of I-shaped pillars compared with the control square pillar array and the conventional cylindrical pillar array. As the pillar array gap size
and gradient are xed across the three pillar types, it would suggest that the effective separation size of RBC in I-shaped pillar array is greater than square pillars and cylindrical pillars.
Bead characterization of the I-shaped device. To conrm our hypothesis that I-shaped pillar is more effective for non-spherical RBC, we characterized the critical separation diameter of the I-shaped pillar device and investigated the critical size of a rotating RBC in the I-shaped pillar array. The separation results of the beads in I-shaped pillar and cylindrical pillar devices are shown in Supplementary Fig. S3. National Institute of Standards and Technology polystyrene beads of size 2.03.5 mm in steps of0.5 mm were used as the lower and upper limits of the test. Two micrometre and 2.5 mm beads were not separated in the conventional DLD device (see Supplementary Fig. S3a). However, slight separation was observed for 3 mm beads, for which the output separation channels ranged from channel 8 to 22 with a peak separation of B26% at channel 18. Though the spread of 3 mm is wide, 85% of the separated beads lie close to the centre regions of channel 1422. The actual critical diameter of the conventional DLD pillar array is between 3 and 3.5 mm, which concurs with the theoretical critical diameter of the device3.33 mm. I-shaped pillars on the other hand do not have a well-established study of its theoretical critical diameter. From the bead ow tests, it is interesting to note that although 2 mm beads were not separated, there was distinct separation for 3 mm beads and signicant deviation of 2.5 mm beads at the output regions (see Supplementary Fig. S3b and Supplementary Note S1). Beads(2.5 mm) peaked at B161.7% separation at channel 6, whereas the output distribution spread was wide and relatively evenly distributed along channels 415. The spread that is observed here
4 NATURE COMMUNICATIONS | 4:1625 | DOI: 10.1038/ncomms2653 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications
& 2013 Macmillan Publishers Limited. All rights reserved.
NATURE COMMUNICATIONS | DOI: 10.1038/ncomms2653 ARTICLE
1 2 3 4 5 6
10 m
1
Rotation and collision to pillar.
Rotate in low velocity region between pillars. 4
5 Recover from rotation
and slide along edge
Continue flowing down the device
6 Slide along the other sideof pillar.
2 3 Pivot at edge and slide along walls of pillar.
Slip past pillar.
1 2 3 4 5 6
10 m
Rotation and collision to pillar.
1
2
Collision on edge of grove
3 5
Flip on edge
6
Rotate and collide to side of pillar
Flip on edge androtate into groove 4
Pivot about edge of groove
Process repeats until rotational momentum changes
1 2 3 4 5 6
10 m
Rotation and collision to pillar.
Flip at edge and slide into groove
Slide within groove
3
Slide out of groove
5
1
Flip and rotate
2
4
Collide into wall and process continues
Figure 3 | RBC movement within square and I-shaped pillars. The major RBC ow movement within the square pillar array (a) and the I-shaped pillars (b, c) are depicted in the form of schematics, as well as video still capture. (a) Primary movement of RBCs in square-shaped pillars in six steps shown in the video still capture as it ows down the non-separated path. (b, c) RBC separation path with two types of observed rotational movements within the I-shaped pillars. Scale bar, 10 mm.
6
seems counter-intuitive to the previous performance of DLD devices, which enables distinct separations18,21,25. The observed phenomenon could be due to DLD mixed separation mode and further elaborated in Supplementary Note S1 (refs 2628). From the results, the effective critical diameter of the I-shaped device can be experimentally deduced to be greater than 2.5 mm and less than 3 mm for distinctive particle separation.
RBC rotational movement. To investigate the inuence of RBC rotation on the increase in effective separation, the movement of RBCs in both square pillar in Fig. 3a and I-shaped pillar array in Fig. 3b are captured and analyzed (see Supplementary Movies S2 and S3). Detailed schematics and screen shots of the motion of RBC within the square control and I-shaped pillar are described
in Fig. 3. Figure 3a depicts the path of RBC, which does not get separated in square pillars. The RBCs movements follow a laminar ow path and ow length-wise close to the side of the pillars; hence, the effective separation diameter of the RBC is B2 mm, which is the width of the RBC. It is also noted that as it collides into the walls of the pillar in step 1 in Fig. 3a, it deforms and conforms to the shape of the pillar, sliding along the walls. During the collision and deformation process in steps 1 and 2 in Fig. 3a, if the RBC does not slide close to the walls of the pillar, it might get displaced from its original laminar ow path (bumped) and get separated. RBC itself is a compliant and deformable object; hence, it is hard to predict its movement in a post-collision scenario within a complex uid ow. Although majority of the RBCs in the square pillar array slides along the pillar unaffected, some of them would be displaced due to the randomness of their
NATURE COMMUNICATIONS | 4:1625 | DOI: 10.1038/ncomms2653 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications 5
& 2013 Macmillan Publishers Limited. All rights reserved.
ARTICLE NATURE COMMUNICATIONS | DOI: 10.1038/ncomms2653
mm s1
3
2.5
2
1.5
1
0.5
0
mm s1
3
2.5
2
1.5
1
0.5
0
10 m 10 m
B
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
Velocity magnitiude (mm s1 )
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
0.0 0.8 1.6 2.5 3.3 4.1 4.9 5.7 6.6 7.4
Position of length of RBC (m)
Velocity magnitiude (mm s1 )
B
A
A
B
A
A
B
0.0 0.6 1.2 1.7 2.3 2.9 3.5 4.1 5.3
4.7 5.9 6.5 7.1 7.8
Position of length of RBC (m)
Figure 4 | COMSOL multiphysics uid ow simulation for square and I-shaped pillars. Comparison of uid ow proles of square pillars (a) and I-shaped pillars (b) can be seen in the simulated ow patterns. Red regions represent high ow rates of B3.5 mm s 1 while dark blue represents zero ow at the no-slip boundary condition. The superimposed elongated rod-shaped gure in light pink is used to represent the position of RBC in the uid ow experiencing different velocities across the RBC body. The graph in c and d shows the cross-section uid ow magnitude experienced by the RBC at its superimposed position in a and b, respectively.
rotation. This would result in a possible bumping and, hence, some separation as observed in the square pillar array, explaining the spread of RBCs throughout the output channels. Figure 3b and c shows two observed motions of RBCs, as they ow past I-shaped pillars. These two gures depict the motion of a RBC that allows it to follow the gradient of pillar array resulting in the nal displacement from the original laminar ow path and hence separation at the output channels. Figure 3b shows a bumping and tumbling motion, whereas Figure 3c shows RBC sliding motion along the sides of the wall, which is similar to the schematics shown for the RBC movement in square pillar array. However, the key difference that enables RBC separation lies in the I-shaped protrusions, which prevent the RBC from taking the usual streamline path by ipping it as it exits the groove of the pillar. Though both types of RBC movements in Fig. 3b and Fig. 3c differ, the I-shaped protrusions act as a two pivot points for the RBC to rotate, and the groove provides room for RBC to ip and tumble within (steps 1 and 4 in Fig. 3b and c). Both RBC movements are not mutually exclusive and can alternate between Fig. 3b and c separation processes. This distinct difference in RBC movement compared with the square pillar shows how a simple groove in the novel I-shaped pillar design would destabilize the streamline ow of the RBC and allow it to ip and rotate, resulting in increased effective size for separation. Hence, the I-shaped pillar have shown to induce rotations of RBC, resulting in a greater effective separating size proposed in our hypothesis.
Computational uid dynamic. To have a basic understanding on how the I-shaped pillars would have induced rotations of RBC, we performed computational analysis on COMSOL Multiphysics4.1 platform for the square pillar array and I-shaped pillar array
to study the uid ow and velocity prole. We wanted to nd out what uid ow conditions would the RBC experience in our devices. For the computation of each device, we have set a simple setup of a minimum two by two pillar array and the initial ow velocity is set to 1 mm s 1 with atmospheric pressures at the outlets. All boundary conditions were set the same for both models. The computational data in Fig. 4 shows the velocity and streamline prole for both devices. It can be seen that square pillars in Fig. 4a have relatively constant and smooth uid streamlines between the pillars, unlike I-shaped pillars in Fig. 4b where the groove between pillars causes a disturbance in peak velocity streamline path. The superimposed RBCs in both gures are placed in the similar positions that can be seen in Fig. 3a (step 2 and 3) and Fig. 3b (step 4 and 5). The RBC in Fig. 4a is placed to mimic a sliding RBC. The graph in Fig. 4c shows the uid velocity ow across the length of the superimposed RBC, as it slides along the walls of the square pillar. The ow velocity does not uctuate when the RBC is in that position. This would support the observation of a sliding RBC. Figure 4d depicts an RBC, which is transiting from step 4 to step 5 as shown in Fig. 3b. In contrast, it shows a drastic variation in ow velocity across the RBC, which has a high (3.2 mm s 1) to a low (close to 0) ow rate. The RBC in such a position depicted in Fig. 4b would experience a deferential ow velocity, resulting in the formation of a net moment acting on the RBC, causing it to rotate. The double protrusions in I-shaped pillar compliment the groove by creating variations in uid streamlines and velocities producing changes in moments on the RBC, hence the observed RBCs rotation and separation in our novel design. Although the I-shaped pillar proves more effective for non-spherical RBCs, it maintains a symmetrical cross-sectional uid ow prole and differs from other unique DLD pillar shape, such as triangular
6 NATURE COMMUNICATIONS | 4:1625 | DOI: 10.1038/ncomms2653 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications
& 2013 Macmillan Publishers Limited. All rights reserved.
NATURE COMMUNICATIONS | DOI: 10.1038/ncomms2653 ARTICLE
shape, with asymmetrical uid ow prole (see Supplementary Fig. S4 and Supplementary Note S2)23.
DiscussionI-shaped pillars have shown to have an increase in separation effectiveness for non-spherical RBCs and it has also reduced the device critical diameter for I-shaped pillars to less than 3 mm.
Further testing was performed to test whether the separation of RBC in I-shaped pillars was due to the reduction of device critical diameter or increase in rotational diameter as hypothesized in Fig. 1b (see Supplementary Fig. S5 and Supplementary Note S3). The RBC rotational diameter was characterized and found to have increased to B3.5 mm and, hence, would conrm that the observed separation in I-shaped pillars was due to an increase in RBC critical diameter. Further testing on increasing ow velocity of up to ten times has shown that the I-shaped pillar remained effective in the separation of non-spherical RBCs with separation critical diameter of more than 3 mm (see Supplementary Fig. S6 and Supplementary Note S4).
To further extend our hypothesis, we briey tested the effects of I-shaped pillars on other non-spherical particle, such as the rod-shaped bacteria, and have found that it was also effective in the separation of the Escherichia coli bacteria. The preliminary studies on extended applications of I-shaped pillar array for rod-shaped bacteria separation resulted in the displacement of a bacteria stream path with a critical diameter of 1.12 mm, which is approximately half of the length of the E. coli bacteria (see Supplementary Fig. S7 and Supplementary Note S5). Conventional DLD pillar arrays were not able to separate the bacteria at those parameters. Currently, separation of bacteria using DLD has not been performed and there are no current comparisons for the DLD study.
We have introduced a novel I-shaped pillar array for the separation of non-spherical bioparticles, such as RBC and E. coli. Our results and computational studies have shown that the I-shaped pillar destabilizes the laminar ow movement of RBC and induces rotation, which supports our hypothesis to enable the effective separation of the disc-shaped RBCs from the sample stream as compared with the conventional cylindrical pillar and square pillar array. Our studies with I-shaped pillar differ from past works in two aspects (see Supplementary Discussions). First, the pillar design and mechanisms for particle separation differ greatly, as we aim to induce continuous rotation and have shown that the rotation and tumbling of disc-shaped RBCs by I-shaped pillar array would result in a focused separation stream. Second, we enable an increase in particle critical diameter by accounting for the shape of particle to be separated from leveraging on its maximum length in a continuous rotation. To conclude, the I-shaped pillar array has been proven to be more effective in the separation of non-spherical bioparticles compared to current particle separation techniques by using the RBCs and E. coli bacteria as proof-of-concepts for the potential separation of the vast number of non-spherical biological entities, such as bacteria, fungi and, maybe, even viruses.
Methods
Device fabrication. The device design shown in Fig. 1a comprises three inlet channels, a pillar-array main channel of 2 cm long and three outlet channels divided into 40 subchannels for characterization of device separation efciency. There are a total of three pillar array designs as shown in Fig. 1c, namely cylindrical pillar, square pillar and the I-shaped pillar. All calculations of DLD were based on formula used by Davis et al.16, as all recent works on RBC separation in DLD devices were designed from the proposed model. As such, all devices used in the paper were based on:
DC 1:4 gN 0:48
where DC critical diameter, g gap size between pillars and N number of rows
per shift in columns (that is tan 1 (1/N) gradient of pillar array).
The designs of the device were drawn on AutoCAD and sent for a chrome-glass mask (Innite Graphics, Singapore) fabrication.
Fabrication of the device was performed in Institute of Materials Research and Engineering in a clean room. The silicon microuidic device was fabricated on a silicon wafer using standard photolithographic and dry etching techniques. The device design in Fig. 1a was transferred from a glass mask to a positive photoresist (AZ5214E, Microchem, MA) coated on the silicon surface by photolithography followed by deep reactive ion etching to a depth of 15 mm. A thin sheet of polydimethylsiloxane (PDMS, Dow Chemicals, MI) was fabricated, and the inlet and outlet holes were punched before this PDMS sheet was bonded over the silicon device, using oxygen plasma (see Supplementary Fig. S1a). AZ5214E (Microchem, MA)-positive photoresist was spin coated on the silicon wafer at 4,000 r.p.m. (rounds per minute) for 1 min and baked at 95 C for another min. The patterns were transferred to the photoresist using a SUSS MA8 photolithography machine. The patterns were developed and hard baked at 125 C for a minute. Oxford 180 dry reactive ion etching machine was used for the fabrication of the pillars. A total of 25 cycles of Bosch etch techniques were performed, with each etch of B0.6 mm per cycle. After the dry etching, the remaining photoresist was removed with acetone, washed for 1 min and dipped in AZ300T (Hoechst, NJ) photoresist stripper for 10 min at 80 C. It is nally rinsed with deionized water. The PDMS (Dow Corning, MI) cover shown in Fig. 1a was initially mixed with a ratio of 10:1 of polymer and curing agent. The mixture was poured into a at glass mould and was degassed for 30 min and baked at 75 C for 45 min. Rectangular pieces of B2 cm by 4 cm were cut and holes of 0.5 mm diameter holes were punched on the PDMS cover. An oxygen plasma machine was used to activate the surface of both the silicon and processed PDMS before aligning the holes to the channels of the device. The nal device was placed overnight to allow the PDMS to bond to silicon properly.
RBC separation. The inlet tubes were attached to the nal device and washed with 1% w/v pluronic F127 (Sigma Aldrich, Singapore) in deionized water for 30 min. This is for surface passivation to prevent any form of non-specic attachment of the sample. The blood sample was extracted from a nger prick and diluted ten times in 1 PBS buffer (Sigma Aldrich, Singapore). The diluted blood sample was
driven by using a syringe pump at a ow rate of 0.2 ml min 1 and sample PBS buffer streams at a ow rate of 0.5 ml min 1. The high-speed video footages on the motion of RBCs were captured by Phantom Miro M310 at frame rates ranging from 250 to 3,000 frames per second. These raw videos were analysed, and results were tabulated and shown in Figs 2 and 3. The output data was compiled by counting and averaging the total number of cells at various output channels for three devices per experiment set. All videos were uncompressed into a real-time video of 60 s. The motion of the particle was slowed by 40 times to allow counting of the number of particles at the outlets. Three videos were captured toget an average number of particle distributions over the subchannels. Though there are no specic subchannels for input, the total number of output channels coincided with the total number of pillars in a horizontal width of the channel, which allowed the tabulation of RBC input distribution. Screen shots were extracted to view the motion and position of RBCs for its interaction with the pillars. Video footages can be found in the Supplementary Movies providedwith this manuscript.
References
1. Hou, H. W. et al. Microuidic devices for blood fractionation. Micromachines
2, 319343 (2011).
2. Kim, E.-S., Kim, S., Choi, K. & Han, K.-H. Micro-/nanotechnology-based isolation and clinical signicance of circulating tumor cells. Biomed. Eng. Lett. 2, 7887 (2012).
3. Augustsson, P., Magnusson, C., Nordin, M., Lilja, H. & Laurell, T. Microuidic, label-free enrichment of prostate cancer cells in blood based on acoustophoresis. Anal. Chem. 84, 79547962 (2012).
4. Gossett, D. et al. Label-free cell separation and sorting in microuidic systems. Anal. Bioanal. Chem. 397, 32493267 (2010).
5. Lenshof, A. & Laurell, T. Continuous separation of cells and particles in microuidic systems. Chem. Soc. Rev. 39, 12031217 (2010).
6. Hammarstrom, B., Laurell, T. & Nilsson, J. Seed particle-enabled acoustic trapping of bacteria and nanoparticles in continuous ow systems. Lab Chip 12, 42964304 (2012).
7. Kirby, D. et al. Centrifugo-magnetophoretic particle separation. Microuid Nanouid 13, 899908 (2012).
8. Tsutsui, H. & Ho, C. M. Cell separation by non-inertial force elds in microuidic systems. Mech. Res. Commun. 36, 92103 (2009).
9. Pamme, N. Continuous ow separations in microuidic devices. Lab Chip 7, 16441659 (2007).
10. Hou, H. W. et al. A microuidics approach towards high-throughput pathogen removal from blood using margination. Biomicrouidics 6, 024115024113 (2012).
11. Hou, H. W. et al. Deformability based cell margination-A simple microuidic design for malaria-infected erythrocyte separation. Lab Chip 10, 26052613 (2010).
NATURE COMMUNICATIONS | 4:1625 | DOI: 10.1038/ncomms2653 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications 7
& 2013 Macmillan Publishers Limited. All rights reserved.
ARTICLE NATURE COMMUNICATIONS | DOI: 10.1038/ncomms2653
12. VanDelinder, V. & Groisman, A. Separation of plasma from whole human blood in a continuous cross-ow in a molded microuidic device. Anal. Chem. 78, 37653771 (2006).
13. Crowley, T. A. & Pizziconi, V. Isolation of plasma from whole bloodusing planar microlters for lab-on-a-chip applications. Lab Chip 5, 922929 (2005).
14. Holm, S. H., Beech, J. P., Barrett, M. P. & Tegenfeldt, J. O. Separation of parasites from human blood using deterministic lateral displacement. Lab Chip 11, 13261332 (2011).
15. Huang, R. et al. A microuidics approach for the isolation of nucleated red blood cells (NRBCs) from the peripheral blood of pregnant women. Prenat. Diagn. 28, 892899 (2008).
16. Davis, J. A. et al. Deterministic hydrodynamics: taking blood apart. Proc. Natl Acad. Sci. USA 103, 1477914784 (2006).
17. Beech, J. P., Holm, S. H., Adolfsson, K. & Tegenfeldt, J. O. Sorting cells by size, shape and deformability. Lab Chip 12, 10481051 (2012).
18. Huang, L. R., Cox, E. C., Austin, R. H. & Sturm, J. C. Continuous particle separation through deterministic lateral displacement. Science 304, 987990 (2004).
19. Inglis, D. W., Davis, J. A., Austin, R. H. & Sturm, J. C. Critical particle size for fractionation by deterministic lateral displacement. Lab Chip 6, 655658 (2006).
20. Bowman, T., Frechette, J. & Drazer, G. Force driven separation of drops by deterministic lateral displacement. Lab Chip 12, 29032908 (2012).
21. Inglis, D. W., Herman, N. & Vesey, G. Highly accurate deterministic lateral displacement device and its application to purication of fungal spores. Biomicrouidics 4, 024109 (2010).
22. Loutherback, K., Puchalla, J., Austin, R. & Sturm, J. Deterministic microuidic ratchet. Phys. Rev. Lett. 102, 045301 (2009).
23. Loutherback, K. et al. Improved performance of deterministic lateral displacement arrays with triangular posts. Microuid Nanouid 9, 11431149 (2010).
24. Sugaya, S., Yamada, M. & Seki, M. Observation of nonspherical particle behaviors for continuous shape-based separation using hydrodynamic ltration. Biomicrouidics 5, 024103024113 (2011).
25. Devendra, R. & Drazer, G. Gravity driven deterministic lateral displacement for particle separation in microuidic devices. Anal. Chem. 84, 1062110627 (2012).
26. Long, B. R. et al. Multidirectional sorting modes in deterministic lateral displacement devices. Phys. Rev. E Stat. Nonlin. Soft Matter Phys. 78, 046304 (2008).
27. Quek, R., Le, D. V. & Chiam, K. H. Separation of deformable particles in deterministic lateral displacement devices. Phys. Rev. E Stat. Nonlin. Soft Matter Phys. 83, 056301 (2011).
28. Heller, M. & Bruus, H. A theoretical analysis of the resolution due to diffusion and size dispersion of particles in deterministic lateral displacement devices. J. Microm. Microeng. 18, 075030 (2008).
Acknowledgements
We acknowledge the National University of Singapore (NUS) and A*STAR SERC (Project number R-397-000-122-305) for the funding support, as well as the Institute of Materials Research and Engineering (IMRE) for providing the microfabrication facilities.
Author contributions
K.K.Z. and S.R. contributed equally to this work, in the lab experimental work. Y.Z. managed the project. K.K.Z., S.R. and Y.Z. conceived and designed the experiments. K.K.Z. designed and fabricated the devices, and performed the computational work. K.K.Z., S.R. and Y.Z. analysed the results and wrote the paper.
Additional information
Supplementary Information accompanies this paper at http://www.nature.com/naturecommunications
Web End =http://www.nature.com/ http://www.nature.com/naturecommunications
Web End =naturecommunications
Competing nancial interests: The authors declare no competing nancial interests.
Reprints and permission information is available online at http://npg.nature.com/reprintsandpermissions/
Web End =http://npg.nature.com/ http://npg.nature.com/reprintsandpermissions/
Web End =reprintsandpermissions/
How to cite this article: Zeming, K. K. et al. Rotational separation of non-spherical bioparticles using I-shaped pillar arrays in a microuidic device. Nat. Commun. 4:1625 doi: 10.1038/ncomms2653 (2013).
8 NATURE COMMUNICATIONS | 4:1625 | DOI: 10.1038/ncomms2653 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications
& 2013 Macmillan Publishers Limited. All rights reserved.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Copyright Nature Publishing Group Mar 2013
Abstract
Most bioparticles, such as red blood cells and bacteria, are non-spherical in shape. However, conventional microfluidic separation devices are designed for spherical particles. This poses a challenge in designing a separation device for non-spherical bioparticles, as the smallest dimension of the bioparticle has to be considered, which increases fabrication challenges and decreases the throughput. If current methods do not take into account the shape of non-spherical bioparticles, the separation will be inefficient. Here, to address this challenge, we present a novel technique for the separation of red blood cells as a non-spherical bioparticle, using a new I-shaped pillar arrays design. It takes the shape into account and induces rotational movements, allowing us to leverage on the largest dimension, which increases its separation size. This technique has been used for 100% separation of red blood cells from blood samples in a focused stream, outperforming the conventional pillar array designs.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer