Imaging live cell in micro-liquid enclosure by X-ray laser diffraction
Takashi Kimura1,*, Yasumasa Joti2,*, Akemi Shibuya3, Changyong Song3, Sangsoo Kim3, Kensuke Tono2, Makina Yabashi3, Masatada Tamakoshi4, Toshiyuki Moriya5, Tairo Oshima5, Tetsuya Ishikawa3, Yoshitaka Bessho3 & Yoshinori Nishino1
Emerging X-ray free-electron lasers with femtosecond pulse duration enable single-shot snapshot imaging almost free from sample damage by outrunning major radiation damage processes. In bioimaging, it is essential to keep the sample close to its natural state. Conventional high-resolution imaging, however, suffers from severe radiation damage that hinders live cell imaging. Here we present a method for capturing snapshots of live cells kept in a micro-liquid enclosure array by X-ray laser diffraction. We place living Microbacterium lacticum cells in an enclosure array and successively expose each enclosure to a single X-ray laser pulse from the SPring-8 Angstrom Compact Free-Electron Laser. The enclosure itself works as a guard slit and allows us to record a coherent diffraction pattern from a weakly-scattering submicrometre-sized cell with a clear fringe extending up to a 28-nm full-period resolution. The reconstructed image reveals living whole-cell structures without any staining, which helps advance understanding of intracellular phenomena.
1 Research Institute for Electronic Science, Hokkaido University, Kita 21 Nishi 10, Kita-ku, Sapporo 001-0021, Japan. 2 Japan Synchrotron Radiation Research Institute/SPring-8, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198, Japan. 3 RIKEN SPring-8 Center, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148, Japan. 4 Department of Applied Life Sciences, Tokyo University of Pharmacy and Life Sciences, 1432-1 Horinouchi, Hachioji, Tokyo 192-0392, Japan.
5 Institute of Environmental Microbiology, Kyowa-kako Co. Ltd., 2-15-5 Tadao, Machida, Tokyo 194-0035, Japan. * These authors contributed equally to this work. Correspondence and requests for materials should be addressed to Y.N. (email: mailto:[email protected]
Web End [email protected] ) or to Y.B.(email: mailto:[email protected]
Web End [email protected] ).
NATURE COMMUNICATIONS | 5:3052 | DOI: 10.1038/ncomms4052 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications 1
& 2014 Macmillan Publishers Limited. All rights reserved.
ARTICLE NATURE COMMUNICATIONS | DOI: 10.1038/ncomms4052
Radiation damage is a serious problem in high-resolution microscopy, for example, electron microscopy or X-ray microscopy, which limits achievable resolution1,2. X-ray
free-electron lasers (XFELs) can overcome the problem by freezing the sample in time using the femtosecond pulse duration instead of cryogenically cooling the sample36. Coherent X-ray diffraction (CXD) using XFELs thus has great potential for high-resolution imaging of biospecimens7,8. CXD has been developed using synchrotron radiation9,10 and applied to high-contrast imaging of biological samples without the need for crystallization1119.
The femtosecond pulse duration of XFELs also has great potential to capture snapshots of biological samples close to its natural state. In this study, we use XFEL to observe living bacterial cells, Microbacterium lacticum (M. lacticum)20. Bacterial genetic information is generally contained in irregularly shaped nucleoids, which have stronger X-ray scattering power because of their phosphorus content21,22. M. lacticum, discovered in milk, is a heat-stable Gram-positive bacterium and is the type species of the genus23. Although contamination by thermoduric bacteria in raw milk is a severe agricultural problem24, little information is available about their cell biology because of their submicron size.M. lacticum has a typical rod shape but is much smaller than ordinary bacteria: it is about half the length and 10% of the volume as compared with Escherichia coli. Therefore, it is difcult to observe internal structures of the cell using conventional optical microscopy.
We propose pulsed coherent X-ray solution scattering (PCXSS) using X-ray laser diffraction, which aims to achieve high-resolution imaging of biological samples in close-to-natural conditions. Figure 1 shows the PCXSS experiment schematically. The key component of our PCXSS experiment is a micro-liquid enclosure array (MLEA) to keep biological samples in a solution close-to-natural conditions. The array structure is necessary in PCXSS experiments because the thin silicon nitride membranes, which separate the solution sample from the vacuum environment, are destroyed by a single XFEL pulse exposure. Similar liquid enclosures have been used to image biological samples in solution with scanning transmission electron microscopy25 and CXD microscopy26. XFEL can further resolve the radiation damage problem for biological samples in solution. We perform
PCXSS measurement to observe living M. lacticum cells in MLEA chips and successfully reveal the internal structures.
ResultsLive cells in MLEA. Figure 2a shows an MLEA chip we developed. We enclosed M. lacticum cells in MLEA and observed under uorescence microscope (Fig. 2b,c). In the uorescence microscopy study, live cells are labelled in green and the dead ones in red (Methods). Our experiment revealed that 99% of the cells are alive in MLEAs at 1 h after enclosure being placed in a vacuum environment. Note here that no uorescent labelling was applied to the samples used in the PCXSS measurement. We also veried that each enclosure remained tightly sealed and retained the solution sample, even when an adjacent enclosure was broken in a vacuum environment. Figure 2d shows a scanning electron microscopy (SEM) image of M. lacticum cells for reference.
PCXSS experimental setup. We performed PCXSS experiments using the SPring-8 Angstrom Compact Free-Electron Laser (SACLA)27 (Methods). The XFEL pulses from the SACLA with a photon energy of 5.5 keV, a pulse duration of B10 fs and a repetition rate of 10 Hz were coherently focused to a1.5 mm 2.0 mm spot size28. The focused XFEL beam
illuminated the sample in an MLEA that was contained in a Multiple Application X-ray Imaging Chamber (MAXIC). Single-shot CXD patterns were recorded with a multiport charge-coupled device (MPCCD) octal sensor29 located 2.319 m downstream from the sample. The MPCCD has 2048 2048
pixels with a pixel size of 50 mm 50 mm.
When using MLEAs, the amount of sample required per XFEL shot does not depend on the repetition rate of XFEL in contrast to continuous sample injection schemes5,6, where samples are wasted in the intervals between XFEL pulses. Therefore, MLEA can bring great benet to maintain a high efciency of sample utilization even with a low repetition rate of SACLA.
Background scattering reduction by MLEA. In a CXD experiment, it is essential to reduce background scattering for high-quality data acquisition. In our PCXSS experiment, MLEA containing saline solution produced lower background scattering
Micro-liquid enclosure
Microbacterium lacticum
SACLA X-ray pulses(5.5 keV)
MPCCD octal sensor (z = 2.319 m)
Micro-liquid enclosure array (MLEA) (z = 0 m : focal point)
KB mirror system
Figure 1 | PCXSS experiment for live cells. The XFEL beam from the SPring-8 Angstrom Compact Free-Electron Laser (SACLA) with a photon energy of5.5 keV was focused at the sample position to a spot size of 1.5 mm 2.0 mm using a Kirkpatrick-Baez (KB) mirror system27,28. An MLEA containing
living M. lacticum cells was placed in a vacuum in the MAXIC instrument. The MLEA was scanned to shoot each enclosure with a single XFEL pulse. Because the pulse duration of the XFEL beam was as short as B10 fs, X-ray laser diffraction occurs before the sample is destroyed36. Single-shot CXD patterns were recorded with a multiport charge-coupled device (MPCCD) octal sensor29.
2 NATURE COMMUNICATIONS | 5:3052 | DOI: 10.1038/ncomms4052 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications
& 2014 Macmillan Publishers Limited. All rights reserved.
NATURE COMMUNICATIONS | DOI: 10.1038/ncomms4052 ARTICLE
than the case without MLEA (Fig. 3); the window frame of each enclosure with an aperture size of B20 mm acts as a guard slit and helps reduce parasitic scattering from upstream components. In addition, because the XFEL beam enters and exits perpendicular to the at surfaces of enclosure windows, uniform phase-advance occurs but no parasitic scattering is generated in principle. The thickness of the MLEA solution layer can be controlled precisely by using a nanometre-scale spacer. It is ideal to make the solution layer slightly thicker than the sample size to minimize background scattering from the solvent. In our experiment, we set the
solution layer to 500 nm to match M. lacticum dimensions, which have a rod shape with B200 nm in diameter and 5001,000 nm in length (Fig. 2d).
CXD patterns from live cells. We succeeded in recording CXD patterns from intact M. lacticum cells with single XFEL pulses (Fig. 4, Supplementary Fig. 1). A few percent of recorded data indicate hitting M. lacticum cells, and a few tens of percent of the hits are likely from a single cell (see Methods for more details on the measurement efciency). We consider that the low hit rate is due to gravitational settling, and it can be improved by, for example, immobilizing cells using silicon nitride membranes coated with polylysine30,31. Note that gravitational settling does not occur for smaller-sized particles where diffusion due to Brownian motion becomes dominant over the gravitational effect (Methods).
X-ray scattering from a submicrometre-sized M. lacticum is weak and is comparable in intensity to the background scattering without MLEA shown in Fig. 3a. This implies that the background scattering reduction effect of MLEA demonstrated in Fig. 3b was essential to the successful recording of the CXD pattern from an M. lacticum.
The dose applied to the cell was estimated to be B100 MGy from an XFEL pulse energy of B60 mJ at the sample position. Note that even highly radiation-resistant Deinococcus radio-durans cannot survive at 20 kGy in conventional imaging methods32.
Numerical simulation of CXD patterns. The CXD pattern in Fig. 4a contains a clear fringe extending in one direction. The fringe spacing and orientation indicates a sample width of 194 nm and is tilted by 28. The width is comparable to the diameter of an M. lacticum cell. The full-period resolution estimated from the highest scattering angle of the fringe is 28 nm (Fig. 4b). Although a CXD pattern from a two-dimensional rectangular object generally produces fringes extending in two directions perpendicular to each other, CXD patterns simulated with three-dimensional cylinder and capsule models typically produce a fringe that extends in one direction (Fig. 4c,d, Supplementary Fig. 2, Methods); a fringe cannot be observed when it does not intersect the Ewald sphere in 3D reciprocal space. When multiple samples are present under an illuminated volume, fringes should appear
10 mm
Dead
Live
Soon after enclosure 1 h later
Figure 2 | MLEA and live-dead experiment. (a) MLEA can retain biological samples in a solution between two thin silicon nitride membranes,which separate the solution sample from a vacuum environment. In the current design, a single 10 mm 10 mm MLEA chip contains a 10 10 array
of enclosures. (b,c) Live-dead experiment was performed to conrm that the MLEA can preserve live cells long enough to perform a PCXSS measurement (Methods). The uorescence microscopy images show live cells in green and dead cells in red and were taken soon after enclosure (b) and 1 h after enclosure (c). During the 1 h interval, MLEA was placed in a vacuum environment to simulate PCXSS measurement. The experiment showed that 99% of the cells are alive in MLEAs at 1 h after enclosure. Scale bars: 5 mm (in b and c). (d) A scanning electron microscopy (SEM)
image of M. lacticum cells shows the typical shapes and sizes (Methods). Scale bar: 500 nm (in d).
403
Spatial frequency (nm1)
0.04
0.04
Spatial frequency (nm1)
148
0.02
0.02
55
0.00
0.00
20
Intensity
(photons/(3x3 pixels))
0.02
0.02
7
3
0.04
0.04
1
0.04 0.02 0.00 0.02 0.04
Spatial frequency (nm1)
0.04 0.02 0.00 0.02 0.04
Spatial frequency (nm1)
Figure 3 | Reduction of background scattering by MLEA window frame. (a) Scattering pattern when nothing was placed at the focal plane. (b) Scattering pattern from saline solution (NaCl 0.9% (w/v)) in MLEA with a solution layer thickness of 500 nm. a and b are shown in a logarithmic scale. The average of 73 shots for each case is shown. The maximum photon counts per pixel for the averaged scattering patterns are 452 for a and 45 for b, and the reduction rate is 9.9%. The average photon counts per pixel are 3.5 for a and 0.5 for b, and the reduction rate is 14.4%. The result demonstrates that the frame of the MLEA window helped reduce parasitic scattering. The average incident pulse energies measured at the optics hutch downstream of the double total-reection mirrors are 203 and 195 mJ per pulse for a and b, respectively. Note that X-ray absorption is negligible for b with a transmission of 98% for 5.5 keV X-rays.
NATURE COMMUNICATIONS | 5:3052 | DOI: 10.1038/ncomms4052 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications 3
& 2014 Macmillan Publishers Limited. All rights reserved.
ARTICLE NATURE COMMUNICATIONS | DOI: 10.1038/ncomms4052
403
0.04
Spatial frequency (nm1)
148
0.00
(photons/(3x3 pixels))
0.02
55
20
Intensity
0.02
7
3
0.04
1
0.04 0.02 0.00 0.02 0.04
Spatial frequency (nm1)
Cylinder model Capsule model
194 nm
Single cylinder
Two-cylinder
200
(photons/(3x3 pixels))
Average intensity
200
100
50
20
10
5
2
1
5.16x103 nm1
100
Intensity (a.u.)
50
86 nm
20
10
750 nm
350 nm
2
5
1
17 nm
0.04 0.02 0.00 0.02 0.04
Two-cylinder model
0.04 0.02 0.00 0.02 0.04
Spatial frequency (nm1)
Spatial frequency (nm1)
1.0
Image intensity (a.u.)
0.0
Figure 4 | Experimental CXD pattern and reconstruction. (a) Measured CXD pattern from a live M. lacticum cell. (b) Line prole in the fringe direction of the measured CXD pattern. (c,d) Simulated CXD patterns in the cylinder (c) and capsule (d) models (Methods). Corresponding 3D structures with Euler angles (28, 40, 0) are shown in the lower panels. (e) Line proles of the simulated CXD patterns in the fringe direction in the single-cylinder
(blue) and the two-cylinder (red) models (Methods). The fringe visibility degrades in the two-cylinder model as compared in the single-cylinder model. (f) Reconstructed image of an M. lacticum cell. (g) TEM image of an M. lacticum cell. ae are shown in a logarithmic scale; f and g are shown in a linear scale. Scale bars: 100 nm (in f and g).
in multiple directions (Supplementary Figs 1a, 2b). The above considerations strongly indicate that the experimental CXD pattern originates from a single M. lacticum cell. In addition, the reduced fringe visibility observed in Fig. 4b has a close relation to the intracellular structure (Fig. 4e, Methods). The simulations above also suggest the possibility of 3D modelling from a single-shot CXD pattern when the sample structure can be parameterized with a simple model.
Image reconstruction. We performed image reconstruction from the experimental CXD pattern shown in Fig. 4a by using the
relaxed averaged alternating reections (RAAR) algorithm33, the noise-tolerant hybrid input-output (HIO) algorithm34 and the shrink-wrap algorithm35 (Methods). Figure 4f shows the reconstructed image of an M. lacticum cell. It is rod shaped with a width and length of B194 nm and B570 nm, respectively, which agreed well with the known shape and size of M. lacticum cells. To test the consistency of the reconstruction, we performed two independent image reconstruction runs using different initial random seeds, and the result in Supplementary Fig. 3 shows the small dependence of reconstruction on initial phases. Full-period spatial resolution of the reconstructed image in the fringe direction was estimated to be B37 nm (Fig. 5)12,36.
4 NATURE COMMUNICATIONS | 5:3052 | DOI: 10.1038/ncomms4052 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications
& 2014 Macmillan Publishers Limited. All rights reserved.
NATURE COMMUNICATIONS | DOI: 10.1038/ncomms4052 ARTICLE
1.0
0.8
0.6
PRTF
0.4
0.2
0.0
0.00 0.01 0.02 0.03 0.04
Spatial frequency (nm1)
Figure 5 | Estimation of resolution using phase-retrieval transfer function. Phase-retrieval transfer function (PRTF)12,36 for the reconstructed
image shown in Fig. 4f averaged over whole shells of the same spatial frequency (magenta line). PRTF averaged over shells within 15 around the fringe direction (black line), and that averaged over shells within 15 around the direction perpendicular to the fringe (turquoise line) are also drawn.
DiscussionWe recorded a single-shot CXD pattern of a live M. lacticum cell in MLEA using SACLA, and successfully reconstructed the cell image (Fig. 4f). It is remarkable that the internal density is non-uniformly distributed throughout the cell. The strong image-intense region in the lower area of the cell is dumbbell shaped, with two islands composed of high intensity and moderately high intensity regions, coloured in white and red, respectively. In the upper area of the cell, non-uniform density is also observed within a weak intensity region. The lower area of the cell may contain highly electron-dense materials, such as DNA molecules. In fact, the image intensity difference between the upper and lower regions of the cell can be roughly explained by assuming that they are mostly composed of protein and nucleic acids, respectively37. Note that the reconstructed image shows the contrast between the sample and the solvent. The image resembles the transmission electron microscopy (TEM) image shown in Fig. 4g. It should be stressed here that the X-ray image was obtained for an unstained living cell, while the TEM image was for a chemically xed ultrathin section stained with uranyl acetate and lead citrate.
Our experiment demonstrated that whole-cell imaging by the proposed PCXSS method can reveal the natural structures of live cells at the nanoscale without any staining, which have been inaccessible by other methods. The results of this research will potentially create a breakthrough in whole-cell biology. For example, the presently achieved resolution, which far exceeds conventional optical microscopy, could provide clues towards understanding nucleoid structures in living cells. Multiple snapshot images could also reveal the dynamics of important cellular events, such as genome replication and subsequent cell division.
The method is also applicable to imaging biomolecules in solution. Important targets include supramolecular complexes, multiple complexes and intrinsically disordered proteins, which are difcult to crystallize. To realize biomolecular imaging with PCXSS, a huge enhancement in the CXD signal is required. A straightforward way to increase the CXD signal is to intensify the XFEL beam by advances in accelerator or X-ray optics technologies38. Another way is to enhance the number of scatterers by illuminating many copies of a molecule in solution. In the latter case, speckled scattering patterns can be
obtained with highly-focused XFELs because neither ensemble averaging nor time averaging occurs in contrast to conventional X-ray solution scattering39. There are different strategies to obtain structural information from speckled scattering patterns from many copies: one is to perform single-particle analysis as practiced in electron microscopy to obtain 3D structures from projection images of many particles in random orientations40,41; another way is to numerically retrieve single-particle CXD data from the scattering patterns of many copies4244. The PCXSS method will also offer insights for protein dynamics by revealing metastable conformations of molecules in solution.
Methods
Preparation of bacterial cells. The M. lacticum NBRC14135T strain was obtained from the Biological Resource Center (NBRC), National Institute of Technology and Evaluation, Kisarazu, Japan. Cells were grown at 37 C with shaking in medium containing 1% (w/v) tryptone (Becton Dickinson and Company, Sparks, MD),0.5% (w/v) Bact Yeast Extract (Becton Dickinson and Company, Sparks, MD) and0.5% (w/v) NaCl, pH 7.0 and were stored in a Microbank (PRO-LAB, Round Rock, TX) at 80 C until use. Cells were subcultured in 200 ml of the culture medium
and incubated at 37 C for 16 h. Cells were collected by centrifugation after ltration through a 1-mm Glass Fibre Membrane (PALL, Port Washington, NY) to remove ne dust contamination in the growth medium. Cells were suspended in0.9% (w/v) NaCl, which had been ltered through a DISMIC-25 cs disposable syringe lter unit (Advantec, Tokyo, Japan). Colony-forming units (CFUs) were determined by counting colony numbers on 1.5% (w/v) agar medium plates, inoculated with 100-ml aliquots of cultures grown for 2 days at 37 C.
Live-dead experiment of bacterial cells in MLEA. Approximately 1 1011 CFU
per ml of M. lacticum cells in 10 ml of 0.9% (w/v) NaCl were treated with the LIVE/ DEAD BacLight Bacterial Viability Kit (Invitrogen), preincubated for 10 min at4 C and then enclosed in an MLEA chip. During incubation for 1 h at 25 C, the MLEA chip was placed in a vacuum of 10 3 Pa to simulate conditions during the
PCXSS experiment. The ratio of living and dead cells was determined by counting the green (live) and red (dead) uorescent cells on photographs obtained by uorescence microscopy (Olympus BX51).
PCXSS experiment. The PCXSS experiment for live M. lacticum cells was performed using BL3 of SACLA27. The XFEL beam from the SACLA had a photon energy of 5.5 keV, a pulse duration of B10 fs and a repetition rate of 10 Hz. The average pulse energy of the beam was 260 mJ per pulse just after the undulator. Higher harmonic X-rays were reduced using double total-reection mirrors in the optics hutch and guided to the experimental stations. In the third experimental station, the beam was focused by a Kirkpatrick-Baez mirror system to a spot size of1.5 mm 2.0 mm (full-width at half maximum)28 at the sample position in the
MAXIC instrument. The MAXIC instrument in a vacuum of B10 3 Pa contains two sets of cross slits, which reduce parasitic scattering from upstream components, and MLEA chips in the focal plane. Each MLEA chip retains a 2-ml aliquot of M. lacticum cells in 0.9% (w/v) NaCl with a cell concentration of
B1 1010 CFU per ml at B25 C. MLEA chips mounted on motorized stages
were scanned to shoot each enclosure with a single pulse.
We aligned the MLEA chip to the XFEL beam by using a retractable on-axis zoom lens camera to observe the sample. For alignment, we rst expose the Silicon frame of an MLEA chip with a single XFEL pulse and mark the damaged spot position on the monitor screen of the zoom lens camera. By using the mark on the monitor screen, we determined the coordinates of each enclosure without exposing it to the XFEL beam.
Single-shot CXD patterns from live M. lacticum cells were recorded with an MPCCD octal sensor29, having 2,048 2,048 pixels with a pixel size of
50 mm 50 mm, located 2.319 m downstream from the sample. The sensor has
single-photon sensitivity with a system noise of B300 electrons at an operating
temperature of 30 C, which corresponds to B0.2 photons for 5.5 keV X-rays.
The variable-size aperture at the centre of the sensor through which the direct beam may passwas set at 3.5 mm.
The line prole of the measured CXD pattern shown in Fig. 4b was computed by averaging the diffraction intensities over a width of 0.0016 nm 1, which corresponds to the width of the central speckle originated from an object with a length of B600 nm. The full-period resolution estimated from the highest scattering angle of the fringe (spatial frequency of 0.035 nm 1) is B28 nm with a threshold of two photons per 3 3 pixels. The threshold was determined by
considering a background intensity of 0.460.92 photons per 3 3 pixels far from
the fringe.
Statistical information about the measurement. A single MLEA chip contains a 10 10 array of enclosures. Each enclosure was exposed to a single XFEL pulse.
NATURE COMMUNICATIONS | 5:3052 | DOI: 10.1038/ncomms4052 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications 5
& 2014 Macmillan Publishers Limited. All rights reserved.
ARTICLE NATURE COMMUNICATIONS | DOI: 10.1038/ncomms4052
Among 100 single-shot data recorded for a single 10 10 array MLEA chip, we
observed a few coherent diffraction patters indicative of hitting M. lacticum cells, and a few tens of percent of the hits are likely from a single cell, although it is difcult to count them precisely for weak diffraction data of submicrometre-sized unstained biospecimens. We consider that the low hit rate is due to gravitational settling, which does not occur for smaller-sized particles where diffusion due to Brownian motion becomes dominant over the gravitational effect. In fact, for gold nanoparticle self-assemblies with a size of B100 nm, the probability of hitting sample was increased to a few tens of percent, an order of magnitude larger than for M. lacticum cells. According to ref. 45, the probability of hitting single soot particles injected using an aerosol sample injector5,45,46 is 0.07%. In femtosecond serial crystallography using a liquid jet sample injector6,47, the probability of recording indexable diffraction patterns was reported to be 3% in ref. 47. Here, liquid jet sample injectors have been used for crystalline samples only, where Bragg diffraction is dominant over background scattering from the liquid jet. MLEA chips can be also usefully applied to micro- and nano-crystals. Here, shadowing of diffracted X-rays by the MLEA substrate limits the maximum scattering angle recordable to B55, when (100) silicon substrates with anisotropic wet-etching is used in MLEA chips.
In our current measurement system, data acquisition rate is very low because of the slow movement of the sample stages. It takes 3 s to move an MLEA chip to the adjacent enclosure with an interval of 600 mm and 417 s to complete a raster scan of a 10 10 array MLEA chip. The hit rate of our measurement is B0.005 particle
diffraction patterns per second. It is technically feasible to develop fast sample stages in synchronization with the XFEL pulses for a relatively low repetition rate of, for example, SACLA. In container-free sample injection schemes, data acquisition has been already performed in synchronization with the XFEL pulses, and higher hit rate is achieved. For example, a hit rate of B0.05 particle diffraction patterns per second has been reported for an aerosol sample injector45,46 and four indexable diffraction patterns per second for a liquid jet sample injector47.
There is also room for improvement in the sample exchange scheme. In our current system, we have to vent the entire chamber of the MAXIC instrument in exchanging samples. In recent measurement, we recorded B104 single-shot data in two days of beamtime. A fast sample exchange scheme in addition to fast sample stages mentioned above will make the measurement much more efcient.
Image reconstruction. Image reconstruction was carried out in two steps on the experimental CXD pattern shown in Fig. 4a after centrosymmetrization. In the rst step, the support area was rened using RAAR33 with shrink-wrap35 (2,000 steps) and subsequent noise-tolerant HIO34 with the xed support (1,000 steps). We set the initial support to have a rectangular shape with a tilt angle of 28 as determined from the fringe direction. The initial support size was set to 270 nm in width and1.2 mm in length. The feedback parameter b was set to 0.87 and the support was updated every 50 iterations with a threshold of 0.05. We initially set the kernel of the shrink-wrap algorithm to 3 pixels and gradually reduced it to 1.5 pixels after 2,000 iterations. Using the results with 5,000 different initial random seeds, 2,891 good quality images with smaller reconstruction-errors were selected, and the new support was estimated by majority. In the renement of the support, the reconstructed images were aligned with each other using the correlation coefcient (c.c.) dened by
c:c: arg max
x;y
Pp;q tp;qrpx;qy
Pp;q t2 p;q
q
Pp;q r2 p;q
ah
J1pka k
rin
rex 1
2
; 2
where C, rex and rin are a constant, the electron densities of the external and internal cylinders, respectively. J1(x) is the rst order Bessel function. It is noted that the line prole does not depends on (ty,tz), nor the Euler angles of the model. rin/rex is set to be 2.5.
SEM and TEM measurements. For the SEM measurement, a JEOL JSM-6320F electron microscope was used at an accelerating voltage of 5 kV; M. lacticum cells were xed with glutaraldehyde and osmium tetroxide, dried by the critical point method and coated with an osmium plasma coater. For the TEM measurement, a JEOL JEM-1200EX electron microscope was used at an accelerating voltage of80 kV; M. lacticum cells were xed with glutaraldehyde and osmium tetroxide, dehydrated with ethanol and embedded in epoxy resin (EPON812) at 60 C; an ultramicrotome was then used to produce 8090 nm-thick sections; the sections were stained with uranyl acetate and lead citrate, and coated with carbon. Sample preparation and measurement of SEM and TEM were performed by Hanaichi UltraStructure Research Institute through an agent of Filgen, Inc.
; 1
where {tp,q} and {rp,q} are the electron densities of two reconstructed images. Possibility of image inversion is also considered here. The rened support has a width and length of B225 nm and B612 nm, respectively. In the second step, image reconstruction was performed using RAAR33 (1,000 steps) and subsequent noise-tolerant HIO34 (1,000 steps) with the xed support. The feedback parameter b was set to 0.87 for both algorithms. Using the results with 5,000 different initial random seeds, 119 images with high similarity (c.c. with a representative40.94) were selected and averaged. Finally, we obtained a rod-shaped image with a width and length of B194 nm and B570 nm, respectively (Fig. 4f).
Numerical simulation of CXD patterns. Supplementary Fig. 2 shows CXD patterns simulated using cylinder and capsule models in several orientations specied by Euler angles. The denition of the Euler angles is explained in Supplementary Fig. 2c. The cylinder has a diameter and height of 194 nm and 750 nm, respectively. The capsule consists of one cylinder, having a diameter and height of 194 nm and 550 nm, respectively, and two hemispheres (caps) with diameters of 194 nm. The object with a height of 750 nm produces a projection image with a height of B600 nm for an Euler angle of (28, 40, 0). In this
orientation, the object can t within the solution layer of MLEA with a depth of B500 nm. Parameters in the PCXSS experiment were used in the simulation.
CXD patterns for the cylinder model with uniform electron-density distribution were computed using an analytical formula. CXD patterns for the capsulemodel were simulated using 100,000 pseudo-particles distributed randomly and uniformly inside the capsule. Each pseudo-particle has a Gaussian electron-density distribution with a s.d. of 3.6 nm. The Euler angles for the two-capsule simulation shown in Supplementary Fig. 2b are (28, 40, 0) and ( 40, 30, 0),
respectively, and the translational vector between the two centres is (400 nm,
200 nm, 0 nm).
Figure 4e demonstrates the degradation of fringe visibility using a two-cylinder model. The model structure consists of the external cylinder, having a diameter and height of A and H, respectively, and the internal cylinder, having a diameter and height of a and h, respectively. The two cylinders are separated by t (tx,ty,tz). Line
prole of the CXD pattern in the fringe direction simulated in the two-cylinder model for Euler angles of (f,y,0) is computed analytically as
Ik C AH
J1pkAk exp 2piktx
References
1. Henderson, R. The potential and limitations of neutrons, electrons and X-rays for atomic resolution microscopy of unstained biological molecules. Q. Rev. Biophys. 28, 171193 (1995).
2. Kirz, J., Jacobsen, C. & Howells, M. Soft X-ray microscopes and their biological applications. Q. Rev. Biophys. 28, 33130 (1995).
3. Neutze, R., Wouts, R., van der Spoel, D., Weckert, E. & Hajdu, J. Potential for biomolecular imaging with femtosecond X-ray pulses. Nature 406, 752757 (2000).
4. Chapman, H. N. et al. Femtosecond diffractive imaging with a soft-X-ray free-electron laser. Nat. Phys. 2, 839843 (2006).
5. Seibert, M. M. et al. Single mimivirus particles intercepted and imaged with an X-ray laser. Nature 470, 7881 (2011).
6. Chapman, H. N. et al. Femtosecond X-ray protein nanocrystallography. Nature 470, 7377 (2011).
7. Bergh, M., Huldt, G., Tmneanu, N., Maia, F. R. N. C. & Hajdu, J. Feasibility of imaging living cells at sub-nanometer resolution by ultrafast X-ray diffraction.Q. Rev. Biophys. 41, 181204 (2008).8. Seibert, M. M. et al. Femtosecond diffractive imaging of biological cells. J. Phys. B 43, 194015 (2010).
9. Miao, J., Charalambous, P., Kirz, J. & Sayre, D. Extending the methodology of X-ray crystallography to allow imaging of micrometre-sized non-crystalline specimens. Nature 400, 342344 (1999).
10. Pfeifer, M. A., Williams, G. J., Vartanyants, I. A., Harder, R. & Robinson, I. K. Three-dimensional mapping of a deformation eld inside a nanocrystal. Nature 442, 6366 (2006).
11. Miao, J. et al. Imaging whole Escherichia coli bacteria by using single-particle X-ray diffraction. Proc. Natl Acad. Sci. USA 100, 110112 (2003).
12. Shapiro, D. et al. Biological imaging by soft X-ray diffraction microscopy. Proc. Natl Acad. Sci. USA 102, 1534315346 (2005).
13. Song, C. et al. Quantitative imaging of single, unstained viruses with coherent X rays. Phys. Rev. Lett. 101, 158101 (2008).
14. Nishino, Y., Takahashi, Y., Imamoto, N., Ishikawa, T. & Maeshima, K. Three-dimensional visualization of a human chromosome using coherent X-ray diffraction. Phys. Rev. Lett. 102, 018101 (2009).
15. Huang, X. et al. Soft X-Ray Diffraction Microscopy of a Frozen Hydrated Yeast Cell. Phys. Rev. Lett. 103, 198101 (2009).
16. Giewekemeyer, K. et al. Quantitative biological imaging by ptychographic X-ray diffraction microscopy. Proc. Natl Acad. Sci. USA 107, 529534 (2010).17. Jiang, H. et al. Quantitative 3D imaging of whole, unstained cells by using X-ray diffraction microscopy. Proc. Natl Acad. Sci. USA 107, 1123411239 (2010).
18. Nelson, J. et al. High-resolution X-ray diffraction microscopy of specically labeled yeast cells. Proc. Natl Acad. Sci. USA 107, 72357239 (2010).
19. Dierolf, M. et al. Ptychographic X-ray computed tomography at the nanoscale. Nature 467, 436439 (2010).
20. Suzuki, K. & Hamada, M. in Bergeys Manual of Systematic Bacteriology 2nd edn, Vol. 5 (eds Goodfellow, M. et al.) 814852 (Springer, New York, 2012).
21. Stanier, R. Y., Ingraham, J. L., Wheelsis, M. L. & Pairtes, P. R. in The microbial world, 5th edn 179182 (Prentice-Hall, New Jersey, 1986).
q
6 NATURE COMMUNICATIONS | 5:3052 | DOI: 10.1038/ncomms4052 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications
& 2014 Macmillan Publishers Limited. All rights reserved.
NATURE COMMUNICATIONS | DOI: 10.1038/ncomms4052 ARTICLE
22. Eltsov, M. & Zuber, B. Transmission electron microscopy of the bacterial nucleoid. J. Struct. Biol. 156, 246254 (2006).
23. Robinson, K. Some observations on the taxonomy of the genus Microbacterium. I. Cultural and physiological reactions and heat resistance.J. Appl. Bacteriol. 29, 607615 (1966).24. Rangaswami, G. & Bagyaraj, D. J. in Agricultural Microbiology 2nd edn,
330346 (PHI Learning, New Delhi, 2005).
25. De Jonge, N. & Ross, F. M. Electron microscopy of specimens in liquid. Nat. Nanotech. 6, 695704 (2011).
26. Nam, D. et al. Imaging fully hydrated whole cells by coherent X-ray diffraction microscopy. Phys. Rev. Lett. 110, 098103 (2013).
27. Ishikawa, T. et al. A compact X-ray free-electron laser emitting in the subngstrm region. Nat. Photon. 6, 540544 (2012).
28. Yumoto, H. et al. Focusing of X-ray free-electron laser pulses with reective optics. Nat. Photon. 7, 4347 (2013).
29. Yabashi, M. & Ishikawa, T. (eds) in XFEL/SPring-8 beamline technical design report ver. 2.0. 4246 (Experimental facility group, SPring-8 joint project for XFEL, Hyogo, 2010).
30. Bolshakova, A. V. et al. Comparative studies of bacteria with an atomic force microscopy operating in different modes. Ultramicroscopy 86, 121128 (2001).
31. Marchesini, S. et al. Massively parallel X-ray holography. Nat. Photon. 2, 560563 (2008).
32. Rothschild, L. J. & Mancinell, R. L. Life in extreme environments. Nature 409, 10921101 (2001).
33. Russell Luke, D. Relaxed averaged alternating reections for diffraction imaging. Inverse Problem 21, 3750 (2005).
34. Martin, A. V. et al. Noise-robust coherent diffractive imaging with a single diffraction pattern. Opt. Express. 20, 1665016661 (2012).
35. Marchesini, S. et al. X-ray image reconstruction from a diffraction pattern alone. Phys. Rev. B 68, 140101 (2003).
36. Chapman, H. N. et al. High-resolution ab initio three-dimensional X-ray diffraction microscopy. J. Opt. Soc. Am. A 23, 11791200 (2006).
37. Svergun, D. I. & Koch, M. H. J. Small-angle scattering studies of biological macromolecules in solution. Rep. Prog. Phys. 66, 17351782 (2003).
38. Mimura, H. et al. Breaking the 10 nm barrier in hard-X-ray focusing. Nat. Phys. 6, 122125 (2010).
39. Prez, J. & Nishino, Y. Advances in X-ray scattering: from solution SAXS to achievements with coherent beams. Curr. Opin. Struct. Biol. 22, 670678 (2012).
40. van Heel, M. et al. Single-particle electron cryo-microscopy: towards atomic resolution. Q. Rev. Biophys. 33, 307369 (2000).
41. Oroguchi, T. & Nakasako, M. Three-dimensional structure determination protocol for noncrystalline biomolecules using X-ray free-electron laser diffraction imaging. Phys. Rev. E 87, 022712 (2013).
42. Kam, Z. Determination of macromolecular structure in solution by spatial correlation of scattering uctuations. Macromolecules 10, 927934 (1977).
43. Saldin, D. K. et al. New light on disordered ensembles: ab initio structure determination of one particle from scattering uctuations of many copies. Phys. Rev. Lett. 106, 115501 (2011).
44. Pedrini, B. et al. Two-dimensional structure from random multiparticle X-ray scattering images using cross-correlations. Nat. Commun. 4, 1647 (2013).
45. Loh, N. D. et al. Fractal morphology, imaging and mass spectrometry of single aerosol particles in ight. Nature 486, 513517 (2012).
46. Bogan, M. J. et al. Single Particle X-ray Diffractive Imaging. Nano Lett. 8, 310316 (2008).
47. Sierra, R. G. et al. Nanoow electrospinning serial femtosecond crystallography. Acta Cryst. D 68, 15841587 (2012).
Acknowledgements
This research was partially supported by the X-ray Free Electron Laser Priority Strategy Program from the Ministry of Education, Sports, Culture, Science and Technology, Japan (MEXT); CREST from the Japan Science and Technology Agency (JST); KAKENHI Grant Numbers 23651126, 22310075, 22540424, and 23860001 from Japan Society for the Promotion of Science (JSPS); and the Cooperative Research Program of Network Joint Research Center for Materials and Devices. We thank the operation and engineering staff of SACLA for helping perform the PCXSS experiment; S. Nitahara and A. Wada for helping perform bacterial experiments; H. Kawamura for helping to collect statistical information about the PCXSS measurement; S. Takeuchi for advice on micro-liquid devices; K. Gohara for advice on the TEM image; S. Ohnuki and S. Isobe for discussion on MLEA; H. Nishiyama and J. Nishii for advice on MLEA fabrication; K. Mitsuoka for advice on electron microscopy; the Nanotechnology Platform Program of MEXT for helping MLEA fabrication; T. Meike and M. Takei for fabrication of jigs to seal MLEA;and T. Nagai, T. Hisabori and T. Nemoto for reading the manuscript and for giving comments.
Author contributions
Y.N. conceived the PCXSS experiment. Y.N., Y.B., Y.J., and T.K. designed the research. Y.B. and T.O. selected the target bacterial species. Y.B., T.M., and T.O. optimized the bacterial cultivation. Y.B., A.S., T.M. and T.O. prepared the bacterial samples. T.K. and Y.N. fabricated MLEA chips. SACLA and the SACLA beamline were the responsibility of T.I. and M.Y. Y.N., T.K., Y.B., Y.J., C.S. and S.K. carried out the PCXSS experiment. K.T. set up and aligned the SACLA beamline. Y.J. and T.K. analysed the PCXSS data. Y.J. performed numerical simulations. Y.B., M.T., T.K. and Y.N. performed the live-dead experiment. Y.N., Y.B. and Y.J. wrote the rst draft of the manuscript with discussion and improvements from all authors.
Additional information
Supplementary Information accompanies this paper on http://www.nature.com/naturecommunications
Web End =http://www.nature.com/ http://www.nature.com/naturecommunications
Web End =naturecommunications
Competing nancial interests: The authors declare no competing nancial interests.
Reprints and permission information is available online at http://npg.nature.com/reprintsandpermissions/
Web End =http://npg.nature.com/ http://npg.nature.com/reprintsandpermissions/
Web End =reprintsandpermissions/
How to cite this article: Kimura, T. et al. Imaging live cell in micro-liquid enclosure by X-ray laser diffraction. Nat. Commun. 5:3052 doi: 10.1038/ncomms4052 (2014).
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-nd/3.0/
Web End =http://creativecommons.org/licenses/by-nc-nd/3.0/
NATURE COMMUNICATIONS | 5:3052 | DOI: 10.1038/ncomms4052 | http://www.nature.com/naturecommunications
Web End =www.nature.com/naturecommunications 7
& 2014 Macmillan Publishers Limited. All rights reserved.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Copyright Nature Publishing Group Jan 2014
Abstract
Emerging X-ray free-electron lasers with femtosecond pulse duration enable single-shot snapshot imaging almost free from sample damage by outrunning major radiation damage processes. In bioimaging, it is essential to keep the sample close to its natural state. Conventional high-resolution imaging, however, suffers from severe radiation damage that hinders live cell imaging. Here we present a method for capturing snapshots of live cells kept in a micro-liquid enclosure array by X-ray laser diffraction. We place living Microbacterium lacticum cells in an enclosure array and successively expose each enclosure to a single X-ray laser pulse from the SPring-8 Angstrom Compact Free-Electron Laser. The enclosure itself works as a guard slit and allows us to record a coherent diffraction pattern from a weakly-scattering submicrometre-sized cell with a clear fringe extending up to a 28-nm full-period resolution. The reconstructed image reveals living whole-cell structures without any staining, which helps advance understanding of intracellular phenomena.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer