Content area

Abstract

Background

The Novalis linear accelerator system, a well developed modality, can be used for stereotactic radiosurgery (SRS). The aim of this study was to clarify the efficiency and safety of Novalis SRS in treating vestibular schwannomas.

Materials and methods

This 4-year retrospective study enrolled 23 patients with 26 vestibular schwannomas (3 patients suffered from neurofibromatosis Type II). Five patients had undergone tumor resection. All 26 tumors were treated using Novalis SRS, with a prescription dose that varied between 10 and 16Gy (mean, 11.8±1.7Gy). The average follow-up period was 56.5±22.1 months (range, 17-87 months).

Results

There were 9 men and 14 women. Their mean age at the time of treatment was 54.0±14.6 years (range, 27-84 years). On average, the original size of the tumor was 19.0±7.2mm in maximal diameter (range, 4.6-39.9mm). At the last follow-up, 20 tumors had regressed (76.9%), and there was no observed change in the size of 3 tumors (11.5%). Three of 26 tumors (11.5%) enlarged more than 2mm in one direction. Thus the ultimate radiological tumor control rate was 88.5% (23/26). In addition, 20 (87.0%) patients retained their pre-irradiation hearing function. Facial and trigeminal nerve function were both preserved in all patients. No death occurred during the follow-up, and no patient was treated with a second SRS or converted to tumor resection.

Conclusion

Novalis SRS is a reliable treatment option for vestibular schwannomas. With an optimal radiation dose, satisfactory tumor control can be achieved while preserving cranial nerve function.

Details

Title
Experience with Novalis stereotactic radiosurgery for vestibular schwannomas
Author
Lo, Wei-Lun; Yang, Ka-Yen; Huang, Yu-Jie; Chen, Wu-Fu; Liao, Chen-Chieh; Huang, Yu-Hua
Pages
30-34
Publication year
2014
Publication date
2014
Publisher
Elsevier Limited
ISSN
03038467
e-ISSN
18726968
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
1520419814
Copyright
Copyright Elsevier Limited 2014