It appears you don't have support to open PDFs in this web browser. To view this file, Open with your PDF reader
Abstract
Artesunate (AS) is a potent antimalarial that is used worldwide for the treatment of malaria. A simple method with a total run time of 12 min was developed and validated for the quantification of AS and dihydroartemisinin (DHA), its active metabolite, in human (heparinized) plasma based on one-step protein precipitation in acetonitrile using artemisinin (ARN) as an internal standard, followed by liquid chromatography with a single quadrupole mass spectrometry system connected to a C18 column. Peak area ratio responses were fitted to the 2nd-order curve type, polynomial equation with weighting (1/concentration) over a quantification range between 3.20/5.33-3,000/5,000 nM (1.23/1.52-1153/1422 ng/mL) of AS/DHA showing linearity with very good correlation (r2 > 0.999). Single ion recordings of 5 µL injections of plasma extracts allowed for limits of detection of 1.02 nM (0.39 ng/mL) for AS and 0.44 nM (0.13 ng/mL) for DHA. The inter-assay and intra-assay accuracy and precision of the method was very good with an inaccuracy of ±12.4% and coefficients of variation of =<10.7% at all tested concentrations. The recovery of the analytes from plasma was >=95%. Other commonly used antimalarials including mefloquine, quinine, and chloroquine, did not interfere with the analysis. Post-preparative tests over 24 h in an autosampler (10 °C) showed that the DHA response was only 2.1% of AS from auto-hydrolysis, and β-DHA was the major, stable epimer that was used for quantification of DHA. In contrast, α-DHA increased steadily up to 600%. Artesunate and DHA in plasma were stable through three freeze/thaw cycles for up to 6 h at room temperature and up to one year at -80 °C.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer