Diagn Interv Radiol 2012; 18:236237
LETTER TO THE EDITOR
Turkish Society of Radiology 2012
Correlation of dynamic multidetector CT findings with pathological grades of hepatocellular carcinoma
3. Demir , Obuz F, Saol , Dicle O. Contribution of diffusion-weighted MRI to the differential diagnosis of hepatic masses. Diagn Interv Radiol 2007; 13:818886.
4. Onishi H, Kim T, Imai Y, et al. Hypervascular hepatocellular carcinomas: detection with gadoxetate disodium-enhanced MR imaging and multiphasic multidetector CT. Eur Radiol 2011 Nov 7. [Epub ahead of print]
We read with interest the original article on the use of dynamic multidetector computed tomography (MDCT) in hepatocellular carcinoma by Tarhan et al. in the December 2011 issue of Diagnostic and Interventional Radiology (1). When reading this interesting article, some basic questions arose, which we would like the authors to answer.
The article, a retrospective evaluation of multiphasic MDCT examinations of the upper abdomen, gave no information about the indications for multiphasic MDCT. In all of the patients included in this retrospective evaluation, the abdominal computed tomography (CT) was performed in four phases: non-contrast-enhanced, arterial, portal venous, and late phase. The authors did not provide kVp or mA values; therefore, the reader cannot estimate the dose exposure. However, given the four scan phases, we would expect a high radiation exposure, especially when considering the age distribution of the patient population (the youngest was one year old). Is this a standard institutional protocol? Since only the range (190 years) is stated for the age distribution, one has no clear idea about the patient population. In addition, why were the multiphasic abdominal/liver studies performed with CT and not with magnetic resonance imaging (MRI)? MRI, the radiation-free modality with the highest soft tissue contrast, enables state-of-the-art dynamic imaging of hepatocellular carcinoma, and provides comprehensive information about the hepatic vasculature and biliary system (2), as well as diffusion information (3), and the use of hepatocyte-specific contrast agents (4). Finally, the authors report that all of their patients were given intravenous contrast medium at 3.5 mL/s with a power injector, which is definitely inappropriate for a one-year-old child.
We believe that radiologists need to make use of MRI instead of CT in liver imaging.
Sedat Alibek, Michael Uder
From the Radiology Institute (S.A. [email protected], M.U.), University of Erlangen, Erlangen, Germany; and the Department of Radiology (S.A.), MVZ Radiologie und Nuklearmedizin, Frth, Germany.
Published online 10 February 2012DOI 10.4261/1305-3825.DIR.5492-11.3
Authors reply
We read the comments of Drs. Alibek and Uder on our recently published article (1), and we would like to clarify the issues they raised.
In our study, our aim was to determine whether the various vascularization patterns of hepatocellular carcinoma (HCC) nodules observed during dynamic MDCT correlate with histopathological differentiation grades. First, this was a retrospective study and we only included the patients who had both dynamic MDCT and pathologically proven HCC from our archives. We reviewed our radiology archives from 2000 to 2007 and, within eight years, we found only 46 patients meeting these criteria. Ours is a transplant center and patients are referred to our hospital for evaluation of eligibility for transplantation. Most of the patients in the study were referred to our hospital for transplantation and our concern was not limited to the determination of HCC; we also evaluated the patency of vascular structures and other possible abnormalities before the decision regarding transplantation. Our transplant surgeons prefer CT examination for evaluation of patients prior to transplantation because, with new multidetector technology, dynamic MDCT is performed in a very short time and is well tolerated by the patients (2). After obtaining the raw data once, evaluating the parenchyma and vascular structures is possible later. Different reconstruction techniques are used for obtaining arterial and portal CT angiography images and 3- to 5-mm thick axial images. CT can be performed in patients having difficulty suspending respiration and still provides valuable data (24). Although MRI has the highest contrast resolution among different imaging modalities, this high contrast is not always sufficient to make it the modality of choice to detect HCC (4). The spatial resolution of magnetic resonance angiography is also inferior to that of CT angiography and catheter angiography (5).
In our department, we perform both dynamic MRI and dynamic multidetector CT examinations for evaluation of the liver, and selection of the examination is made for each individual based on the clinicians concerns and the patients condition.
Only four patients younger than 18 years were enrolled and their ages were 1, 9, 13, and 16 years. The injection rate provided in the paper is the one we used in our standard protocol for dynamic MDCT; however, for children, we do
References
1. Tarhan N, Hatipolu T, Ercan E, et al. Correlation of dynamic multidetector CT findings with pathological grades of hepatocellular carcinoma. Diagn Interv Radiol 2011; 17:328333.
2. Semelka RC, Shoenut JP, Kroeker MA, et al. Focal liver disease: comparison of dynamic contrast-enhanced CT and T2-weighted fat-suppressed, FLASH, and dynamic gadolinium-enhanced MR imaging at 1.5 T. Radiology 1992; 184:68786894.
236
not use this injection rate. For children, injection rates are, approximately, between 1.0 and 2.0 mL/s and change according to the patients age and weight.
In our standard multidetector CT protocol, the kV and effective mA used are 120 and 110 respectively (effective mA=mA/pitch). This also changes according to the patients weight; thus, minor changes are made even while the patient is on the examination table. When examining children, we prefer to use the CARE Dose four-dimensional (4D) protocol (Siemens Medical Solutions, Forchheim, Germany) (6). CARE Dose 4D is an automatic exposure control that includes automatic tube current adaptation to the patients size and anatomic shape together with an online-controlled tube current modulation for each tube rotation. This provides well balanced image quality at low radiation dose levels.
New techniques such as virtual unenhanced dual-source CT can also be used to image these patients. Studies have been reported showing that virtual unenhanced images can replace conventional unenhanced images, thereby significantly reducing the radiation dose received by the patient (7).
Nefise ala Tarhan, Tue Hatipolu, Eyll Ercan, Merve Bener, Gksun Kele, Ceyla Baaran, Banu Bileziki
From the Departments of Radiology (N..T. [email protected], T.H., E.E., M.B., G.K., C.B.) and Pathology (B.B.), Bakent University School of Medicine, Ankara, Turkey.
Published online 10 February 2012DOI 10.4261/1305-3825.DIR.5523-11.1
References
1. Tarhan N, Hatipolu T, Ercan E, et al. Correlation of dynamic multidetector CT findings with pathological grades of hepatocellular carcinoma. Diagn Interv Radiol 2011; 17:328333.
2. Atasoy , Akyar S. Multidetector CT: contributions on liver imaging. Eur J Radiol 2004; 52:27.
3. Cokun M, Kayahan EM, zbek O, akr B, Dalg A, Haberal A.
Imaging of hepatic arterial anatomy for depicting vascular variations in living related liver transplant donor candidates with multi-detector computed tomography: comparison with conventional angiography. Transplant Proc 2005; 37:10701073.
4. Mahfouz AE, Vogl T, Hamm B. Tumor diagnosis in the adult liver transplant candidate. Eur Radiol 1999; 9:841852.
5. Sahani D, Mehta A, Blake M, Prasad S, Harris G, Saini S. Preoperative hepatic vascular eva luation with CT and MR angiography. Radiographics 2004; 24:13671380.
6. Sodenberg M, Gunnarsson M. The effect of different adaptation strengths on image quality and radiation dose using Siemens Care Dose 4D. Radiat Prot Dosimetry 2010; 139:173179.
7. Barrett T, Bowden DJ, Shaida N, et al. Virtual unenhanced second generation dual-source CT of the liver: is it time to discard the conventional unenhanced phase? Eur J Radiol 2011; Apr 16. [Epub ahead of print]
Volume 18 Issue 2
Correlation of dynamic multidetector CT findings with pathological grades of hepatocellular carcinoma 237
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer