© 2015 Huang et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Background

A new lateral flow immunoassay (LFA) for the detection of cryptococcal antigen was developed.

Objective

We aimed to systematically review all relevant studies to evaluate the diagnostic accuracy of the cryptococcal antigen LFA on serum, CSF and urine specimens.

Methods

We searched public databases including PubMed, Web of Science, Elsevier Science Direct and Cochrane Library for the English-language literature published up to September 2014. We conducted meta-analyses of sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR) and diagnostic odds ratios (DOR) and SROC of LFA in serum and CSF, respectively. The sensitivity of LFA in urine was also analyzed. Subgroup analyses were carried out to analyze the potential heterogeneity.

Results

12 studies were included in this study. The pooled sensitivity and specificity values of LFA in serum were 97.6% (95% CI, 95.6% to 98.9%) and 98.1% (95% CI, 97.4% to 98.6%), respectively. The average PLR of LFA in serum was 43.787 (95% CI, 22.60–84.81) and the NLR was 0.03 (95% CI, 0.01–0.09). The pooled DOR was 2180.30 (95% CI, 868.92–5471.00) and the AUC was 0.9968. The pooled sensitivity and specificity values of LFA in CSF were 98.9% (95% CI, 97.9% to 99.5%) and 98.9% (95% CI, 98.0% to 99.5%), respectively. The average PLR of LFA in serum was 48.83 (95% CI, 21.59–110.40) and the NLR was 0.02 (95% CI, 0.01–0.04). The pooled DOR was 2931.10 (95% CI, 1149.20–7475.90) and the AUC was 0.9974. The pooled sensitivity value of LFA in urine was 85.0% (95% CI, 78.7% to 90.1%)

Conclusions

The study demonstrates a very high accuracy of LFA in serum and CSF for the diagnosis of cryptococcosis in patients at risk. LFA in urine can be a promising sample screening tool for early diagnosis of cryptococcosis.

Details

Title
Evaluation of a New Cryptococcal Antigen Lateral Flow Immunoassay in Serum, Cerebrospinal Fluid and Urine for the Diagnosis of Cryptococcosis: A Meta-Analysis and Systematic Review
Author
Hua-Rong, Huang; Li-Chao, Fan; Rajbanshi, Bhavana; Jin-Fu, Xu
First page
e0127117
Section
Research Article
Publication year
2015
Publication date
May 2015
Publisher
Public Library of Science
e-ISSN
19326203
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
1680963900
Copyright
© 2015 Huang et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.