Full Text

Turn on search term navigation

© 2015 Jonas et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Purpose

To measure the distance between the optic disc center and the fovea (DFD) and to assess its associations.

Methods

The population-based cross-sectional Beijing Eye Study 2011 included 3468 individuals aged 50+ years. The DFD was measured on fundus photographs.

Results

Readable fundus photographs were available for 2836 (81.8%) individuals. Mean DFD was 4.76 ± 0.34mm (median: 4.74 mm; range: 3.76–6.53mm). In multivariate analysis, longer DFD was associated with longer axial length (P<0.001; standardized correlation coefficient beta: 0.62), higher prevalence of axially high myopia (P<0.001; beta:0.06), shallower anterior chamber depth (P<0.001; beta:-0.18), thinner lens thickness (P = 0.004; beta: -0.06), smaller optic disc-fovea angle (P = 0.02; beta: -0.04), larger parapapillary alpha zone (P = 0.008; beta: 0.05), larger parapapillary beta/gamma zone (P<0.001; beta: 0.11), larger optic disc area (P<0.001; beta: 0.08), lower degree of cortical cataract (P = 0.002; beta: -0.08), and lower prevalence of age-related macular degeneration (P = 0.001; beta: -0.06). Bruch´s membrane opening-fovea distance (DFD minus disc radius minus parapapillary beta/gamma zone width) in non-glaucomatous eyes was not significantly (P = 0.60) related with axial length in emmetropic or axially myopic eyes (axial length ≥23.5 mm), while it increased significantly (P<0.001; r: 0.32) with longer axial length in eyes with an axial length of <23.5mm. Ratio of mean DFD to disc diameter was 2.65 ± 0.30. If the ratio of disc-fovea distance to disc diameter was considered constant and if the individual disc diameter was calculated as the individual disc-fovea distance divided by the constant factor of 2.65, the resulting calculated disc diameter differed from the directly measured disc diameter by 0.16 ±0.13 mm (median: 0.13 mm, range: 0.00–0.89 mm) or 8.9 ± 7.3% (median: 7.4%; range: 0.00–70%) of the measured disc diameter.

Conclusions

DFD (mean: 4.76mm) increases with longer axial length, larger parapapillary alpha zone and parapapillary beta/gamma zone, and larger disc area. The axial elongation associated increase in DFD was due to an enlargement of parapapillary beta/gamma zone while the Bruch’s membrane opening-fovea distance did not enlarge with longer axial length. This finding may be of interest for the process of emmetropization and myopization. Due to its variability, the disc-fovea distance has only limited clinical value as a relative size unit for structures at the posterior pole.

Details

Title
Optic Disc - Fovea Distance, Axial Length and Parapapillary Zones. The Beijing Eye Study 2011
Author
Rahul Arvo Jonas; Ya Xing Wang; Yang, Hua; Li, Jian Jun; Xu, Liang; Panda-Jonas, Songhomitra; Jost, Bruno Jonas
First page
e0138701
Section
Research Article
Publication year
2015
Publication date
Sep 2015
Publisher
Public Library of Science
e-ISSN
19326203
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
1719289514
Copyright
© 2015 Jonas et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.