Abstract
High repetition-rate satellite laser ranging (SLR) offers new possibilities for the post-processing of the range measurements. We analyze 11 years of kHz SLR passes of the geodetic satellite Ajisai delivered by Graz SLR station (Austria) in order to improve the accuracy and precision of the principal SLR data product - normal points. The normal points are calculated by three different methods: 1) the range residuals accepted by the standard 2.5 sigma filter, 2) the range residuals accepted by the leading edge filter and 3) the range residuals given by the single corner cube reflector (CCR) panels of Ajisai.
A comparison of the statistical parameters of the obtained results shows that the selection of the range measurements from the leading edge of the SLR data distribution allows to minimize the satellite signature effect and to reduce the average single-shot RMS per normal point from 15.44 to 4.85 mm. The optical distance between the leading edge mean reflection point and the satellite's center of mass is 1,023 mm, RMS=1.7 mm.
Further, in addition, we utilize the complete attitude model of Ajisai during the post-processing which enables selection of the range measurements to the single CCR panels of the satellite and the formation of the normal points which most closely approximate the physical distance between the ground station and the center of mass of Ajisai. This method eliminates the satellite signature effect from the distribution of the post-fit range residuals and further improves the average single-shot RMS per normal point to 3.05 mm. The normal point RMS per pass is reduced from 2.97 to 0.06 mm - a value expected for a zero-signature satellite.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer