J. Sens. Sens. Syst., 5, 916, 2016 www.j-sens-sens-syst.net/5/9/2016/ doi:10.5194/jsss-5-9-2016 Author(s) 2016. CC Attribution 3.0 License.
A. Tempelhahn, H. Budzier, V. Krause, and G. Gerlach
Technische Universitt Dresden, Electrical and Computer Engineering Department, Solid-State Electronics Laboratory, Dresden, Germany
Correspondence to: A. Tempelhahn ([email protected])
Received: 6 October 2015 Accepted: 30 November 2015 Published: 15 January 2016
Abstract. Infrared (IR) cameras based on microbolometer focal plane arrays (FPAs) are the most widely used cameras in thermography. New elds of applications like handheld devices and small distributed sensors benet from the latest sensor improvements in terms of cost and size reduction. In order to compensate for disturbing inuences derived from changing ambient conditions, radiometric cameras use an optical shutter for online recalibration purposes, partially also together with sensor temperature stabilization. For these new applications, IR cameras should consist only of infrared optics, a sensor array, and digital signal processing (DSP). For acceptable measurement uncertainty values without using an optical shutter (shutter-less), the disturbing inuences of changing thermal conditions have to be treated based on temperature measurements of the camera interior. We propose a compensation approach based on calibration measurements under controlled ambient conditions. All correction parameters are determined during the calibration process. Without sensor temperature stabilization (TEC-less), the pixel responsivity is also affected by the camera temperature changes and has to be considered separately. This paper presents the details of the compensation procedure and discusses relevant aspects to gain low temperature measurement uncertainty. The residual measurement uncertainty values are compared to the shutter-based compensation approach.
1 Introduction
The evolution of infrared (IR) thermography including the discovery of new elds of applications is based on the development of small, power-efcient and, most of all, low-cost IR sensors. Microbolometer focal plane arrays (FPAs) are thermal sensors and are also called uncooled sensors because they work at room temperature without any cooling.This cost-reducing benet compared to photon sensors is the reason why microbolometers are widely used in process control, re prevention, re protection and surveillance as well as for research and development tasks.
Each pixel of a microbolometer sensor array acts as a single sensor element. To ensure the required thermal isolation, such a microbolometer pixel consists of a semiconductor bridge and is coated with the bolometer material (Fig. 1). The cavity beneath the micro-bridge works as a /4-resonator/absorber. The entire sensor has to be under vacuum atmosphere for thermal isolation reasons. The temperature of the bolometer bridge changes due to the absorbed inci-
Shutter-less calibration of uncooled infrared cameras
dent radiation. This temperature change affects the electrical resistance of the bolometer material due to its temperature coefcient of resistance (TCR). Common resistor materials are amorphous silicon (a-Si) and vanadium oxide (VOx) with a thin lm TCR of about 0.03 and 0.027 K, respec
tively (Budzier and Gerlach, 2011). The change in electrical resistance is determined using a readout integrated circuit (ROIC) within the silicon substrate generating a radiation-proportional voltage signal for each pixel. The raw infrared data set comprises the signal voltages of the entire sensor array and contains temperature information from the observed scene but also from the camera interior due to the huge eld of view (FOV) of the pixels.
The state-of-the-art semiconductor fabrication technology enables microbolometer sensors with 17 m pixel pitch and a wide variety of spatial resolutions from about 80 80 to
1024 768 pixel (Tissot et al., 2013). This leads to sensor
sizes from a few centimeters down to only a few millimeters depending on the pixel resolution of the sensor. Sensor manufacturers recently made a lot of efforts to improve
Published by Copernicus Publications on behalf of the AMA Association for Sensor Technology.
10 A. Tempelhahn et al.: Shutter-less calibration of uncooled infrared cameras
Figure 1. Bridge structure of a single microbolometer pixel (Moreno et al., 2012). the vacuum packaging technology from common chip levelpackages (CLPs) via wafer level packaging (WLP) to pixellevel packaging (PLP). This integration of vacuum packaging technology into the semiconductor processing will dramatically reduce the sensor cost and, therefore, will make microbolometer FPAs more attractive for lowest-cost applications like handheld devices and small distributed IR sensors (Hoelter et al., 2015; Takasawa, 2015).
IR cameras are used for radiometric measurement of temperature distributions. Here, two concerns mainly have to be taken into account: the sensor non-uniformity due to fabrication variations and the inuences derived from changing ambient conditions, especially the ambient temperature. In the past such cameras used an integrated thermoelectric cooler (TEC) for keeping the temperature of the FPA constant and preventing the sensor parameters offset voltage and responsivity to change according to the ambient temperature. But the high power consumption of this stabilization is a big drawback and is the decisive reason for using TEC-less microbolometer FPAs, e.g., for mobile IR devices or distributed sensor networks.
The correction approaches for infrared imagers and radio-metric cameras differ in the required calibration effort (Tempelhahn et al., 2015). Radiometrically calibrated infrared cameras typically use optical shutters for runtime recalibration purposes in order to regularly correct thermal drift inuences on the measurement. The calibration procedure for the shutter-based compensation approach is presented in detail in Budzier and Gerlach (2015). But the shutter is often the size-limiting component of an infrared camera because it has to cover the entire aperture. Another drawback of the shutter-based compensation approach is the interruption of the measurement during recalibration. Therefore, shutter-less infrared cameras are advantageous, especially for the new elds of application mentioned above. This paper presents a novel shutter-less compensation approach based on a cali-
bration procedure for determining correction parameters that allow one to compensate for the disturbing inuences of a changing ambient temperature. Relevant aspects to gain low temperature measurement uncertainty are discussed and compared to the shutter-based compensation approach.
2 Radiation model
In the following, the setup of an IR camera as shown in Fig. 2 is considered. The microbolometer FPA consists of pixels located in line i and column j. The exchanged (incident minus emitted) radiant ux [Phi1]ij of each pixel (ij) is converted into the raw signal voltage Vraw,ij corresponding to the linear relation between radiation and signal voltage,
Vraw,ij = RV,ij [Phi1]ij + V0,ij , (1)
with the two sensor parameters responsivity RV,ij and offset voltage V0,ij . Both of them vary over the sensor array due to process variations during the sensor fabrication. Furthermore, both also depend on the sensor temperature #fpa.
Previous investigations have shown that the pixels eld of view covers nearly the entire half space. Therefore, the corresponding pixels projected solid angle !pix amounts almost to (Tempelhahn et al., 2013). Infrared cameras usually comprise infrared optics with an f -number about unity. For that reason, the projected solid angle !obj related to the object irradiance Eobj is about 1/5 of !pix (Budzier, 2014). The remaining projected solid angle !cam equals 4/5 of !pix and is covered by the camera interior. Hence, each pixel also detects the irradiance Ecam emitted by the camera housing and depending on the camera temperature #cam. Furthermore, each pixel emits the radiant exitance Mpix into the environment due to the sensor temperature #fpa. The exchanged radiant ux [Phi1]ij from Eq. (1) can be written as a product of the pixel area Apix and a linear combination of these three radiant den-
J. Sens. Sens. Syst., 5, 916, 2016 www.j-sens-sens-syst.net/5/9/2016/
A. Tempelhahn et al.: Shutter-less calibration of uncooled infrared cameras 11
Figure 2. Radiation components in an infrared camera. Eobj radiation derived from the object depending on its temperature #obj covering the projected solid angle !obj, Ecam radiation from the camera interior related to the camera temperature #cam and the solid angle !cam, as well as the radiant exitance Mpix of the sensor depending on the sensor temperature #fpa emitted into the projected solid angle !pix.
sities with their corresponding projected solid angles:
[Phi1]ij =Apix
Figure 3. Correction procedure for shutter- and TEC-less IR cameras.
rived from camera radiation, and the pixel radiant exitance.
offsetij #fpa,#cam
[parenrightbig]
(5)
= V0,ij #fpa
[parenrightbig]
+Vcam,ij #fpa,#cam
[parenrightbig]
+Vpix #fpa
[parenrightbig]
!obj,ij Eobj
+!cam,ij (2)
Ecam (#cam) Mpix #fpa
[parenrightbig][bracketrightbig]
#obj [parenrightbig]
.
3 Correction approach
The suggested approach adapts the shutter-based correction procedure presented in Budzier and Gerlach (2015) and considers the different disturbing inuences separately. Figure 3 illustrates the owchart of the calibration procedure to determine the necessary correction coefcients.
First, the bias voltages of the microbolometer have to be adjusted according to the required object and ambient temperature ranges. The rst bad pixel replacement procedure determines pixels that show no response or have an abnormal behavior.
The main calibration steps are non-uniformity correction (NUC) as well as gain and offset correction. As mentioned before, each microbolometer FPA shows a pixel non-uniformity due to the semiconductor fabrication process. This can be corrected by applying the two-point nonuniformity correction (NUC) based on a slope coefcient aij and an intercept coefcient bij :
Vnuc,ij = aij Vraw,ij + bij . (6)
The NUC is bound to a certain ambient temperature #amb,ref. Changes in the ambient temperature #amb are trans-
www.j-sens-sens-syst.net/5/9/2016/ J. Sens. Sens. Syst., 5, 916, 2016
Figure 2 illustrates this radiation composition and points out the inuences of the three temperatures of the object, the camera and the sensor on the exchanged pixel radiant ux [Phi1]ij . The projected solid angles !obj and !cam of each pixel depend on the position within the FPA and are rotation-symmetrically distributed relating to the optical axis of the IR optics.
By replacing [Phi1]ij from Eq. (1) with Eq. (2), it is possible to separate Eobj containing the essential object temperature information #obj from all other disturbing inuences:
Vraw,ij #obj,#cam,#fpa
[parenrightbig]
=gainij #fpa
[parenrightbig]
Eobj,ij #obj
[parenrightbig]
(3)
+offsetij #cam,#fpa
[parenrightbig]
.
The slope gainij of the pixel-specic linear equation comprises the pixel area Apix, the object-projected angle !obj,ij and the sensors temperature-dependent responsivity RV,ij :
gainij #fpa
[parenrightbig]
= Apix!obj,ij RV,ij #fpa
. (4)
The intercept offsetij combines different disturbing parts: the offset voltage V0,ij , the signal parts Vcam,ij and Vpix de-
[parenrightbig]
12 A. Tempelhahn et al.: Shutter-less calibration of uncooled infrared cameras
ferred inside the camera housing due to heat conduction and convection, and change the cameras and sensors temperature with specic delay times and time constants.
The sensor temperature dependency of the pixel responsivity RV,ij is determined using two switchable blackbodies at different constant temperatures. This ensures a constant incident radiant ux difference [Delta1][Phi1]. Changes in RV,ij are measured using the signal voltage difference [Delta1]V in relation to the sensor temperature #fpa via the relation
RV =
[Delta1]V
[Delta1][Phi1]. (7)
The regression function gV,ij is based on several supporting points at different ambient temperatures and, hence, different sensor temperatures. Using this pixel gain correction function, the NUC-corrected signal voltage is weighted:
Vgain,ij =
Table 1. Properties of the used infrared camera.
Manufacturer ULIS, FranceSensor type UL03162-028TEC w/oShutter w/oNETD < 100 mK (F/1, 300 K, 50 Hz) Resolution 384 288
Pixel pitch 25 m Uniformity (deviation) < 1.5 %Power consumption < 100 mW f -number 1.0Focal length 18 mm
4 IR camera setup
The mentioned calibration procedure will be demonstrated for an IR camera comprising a microbolometer sensor array without temperature stabilization (Table 1).
The sensor temperature #fpa is provided by the detector itself and it is assumed that changes are uniformly distributed over the entire sensor array. The sensor specication describes the sensor temperature dependency of the pixel responsivity with a polynomial of the second order,
RV,ij #fpa
[parenrightbig]
Vnuc,ij
gV,ij #fpa
[parenrightbig]
. (8)
The offset correction considers the temperature inuences in Eq. (5). The offset voltage V0,ij and the signal voltage part
Vpix are compensated for in relation to #fpa. The signal voltage part Vcam,ij corresponding to the disturbing camera radiant ux is estimated based on additional temperature information #cam from inside the camera using a polynomial regression function of the second order:
Vcam,ij (#cam) = c0,ij + c1,ij #cam + c2,ij #2cam. (9)
The offset correction function oV,ij is pixel-specic and can be based on more than one camera temperature value, since the camera temperature measurement depends on the position of the thermometer:
Voffset,ij = Vgain,ij oV,ij #fpa,#cam
[parenrightbig]
= r0,ij + r1,ij #fpa + r2,ij #2fpa, (11)
and the sensor temperature dependency of the pixel offset voltage with a polynomial of the third order,
V0,ij #fpa
[parenrightbig]
= v0,ij + v1,ij #fpa + v2,ij #2fpa + v3,ij #3fpa. (12)
The camera temperature is not homogeneously distributed inside the camera. Electrical losses derived from the digital signal processor (DSP) and the sensor array cause a temperature gradient between positions close to the sensor and in the inner side of the camera housing. For that reason, three temperature probes (LM61, Texas Instruments, USA) are placed inside the camera housing in different positions (Fig. 4). Each of the temperature probes TP1TP3 shows different temporal step responses to changes in the ambient temperature #amb.
The response time of the temperature probes, which indicates how fast temperature changes occur, varies from 39 s for TP1 and 66 s for TP2 to 105 s for TP3. The same relations occur in terms of time constants that give information about the temperature settling time until the steady state is reached.The raw signal voltage Vraw,ij responds to an ambient temperature change, even before TP1 reacts to those temperature changes, and reaches the steady state together with TP3. This demonstrates that each temperature probe provides different temporal information about occurring temperature changes, and should be used for compensation. The offset compensation based on different temperature probe values should benet from having more information about temperature probes due to the possibility of capturing the cameras temperature
J. Sens. Sens. Syst., 5, 916, 2016 www.j-sens-sens-syst.net/5/9/2016/
. (10)
After this ambient temperature compensation, the signal voltage Voff,ij should depend only on the object temperature #obj. Pixels that cannot be corrected appropriately are rejected due to the second bad pixel replacement procedure.
The conversion of the signal voltage level into real temperature values is the last step. This transfer function is based on either a second-order polynomial or a Planck-like regression function that has to be determined using a sufcient number of measurements of known temperatures as supporting data points (Budzier and Gerlach, 2015).
The proposed compensation approach can be easily adapted for infrared cameras using microbolometer FPAs with TEC. If the sensor temperature #fpa is stabilized, then the sensor parameters RV,ij and V0,ij stay constant and the intercept offsetij depends only on the camera temperature #cam. For that reason, the gain correction step can be skipped and the offset correction step can be simplied.
A. Tempelhahn et al.: Shutter-less calibration of uncooled infrared cameras 13
Table 2. Properties of the used blackbodies.
Property Water bath blackbody RCN 300 4 element Peltier blackbody
Manufacturer Self-built HGH Infrared Systems, France Self-built Working principle Water bath Blackbody Blackbody Radiator size 350 350 mm 300 300 mm 4 35 35 mm
Material Copper water tank Aluminium block Copper plate Radiator size Volume 20 L Thickness 50 mm Thickness 3 mm Temperature range 080 C 25300 C 10100 C
Figure 5. Photograph of the calibration setup.
A mechanically moved plate is controlled to open and close the lateral opening of the heating chamber in order to guarantee a homogeneous chamber temperature distribution and to reduce the convection between the heating chamber and the outside. Several thermo-elements were placed inside and outside the heating chamber to observe the temperature changes. The blackbody temperatures were captured using pyrometers.
5.2 Non-uniformity correction (NUC)
The NUC is based on raw infrared images of at least two different blackbody temperatures that should be spread over the targeted measurement range. The surface temperature should be uniformly distributed over the entire camera eld of view.The pixel-dependent slope and intercept values of the pixel response curves from Eq. (3) are equalized, yielding the deviation [Delta1]Vij :
[Delta1]Vij = Vraw,ij Vnuc = aij Vraw,ij + bij . (13)
The resulting linear system of equations is solved in order to determine the pixel coefcients aij and bij (Fig. 6). After the NUC, each pixel shows the same behavior when looking at an object with the same surface temperature since the pixel responses follow the same so-called standard curve. However, this works only for certain ambient temperature conditions when the NUC images were taken. The accuracy of the
www.j-sens-sens-syst.net/5/9/2016/ J. Sens. Sens. Syst., 5, 916, 2016
Figure 4. Positions of the temperature sensor sites inside the camera housing and the detector. TP1 (red) is placed on the front plate carrying the optics. TP2 (green) is located on the front side of the optical channel. TP3 (blue) is placed close to the detector and the signal processing unit on the back side of the optical channel. The fourth site is located inside the sensor array itself (violet).
changes completely with respect to the direction of its propagation.
5 Calibration
In the following, the experimental results of the proposed calibration method using the IR camera from Table 1 will be presented. First, the calibration stand will be explained.
5.1 Calibration stand
The calibration stand was designed to meet the requirements of the proposed calibration procedure. The changing ambient temperature was simulated by using a heating chamber with the infrared camera positioned inside. A lateral opening allows the camera to be face panel blackbodies or testing scenes (Fig. 5).
For the NUC and the ambient temperature compensation steps, two panel blackbodies were used (Table 2):(1) RCN 300 from HGH Infrared Systems, France, and (2) a self-built water bath blackbody. A self-built four-element blackbody comprising four independently working small Peltier element radiators was used for radiometric calibration and testing purposes.
14 A. Tempelhahn et al.: Shutter-less calibration of uncooled infrared cameras
Figure 6. NUC coefcient matrices aij (a) and bij (b). The central symmetric shape of aij is due to the relation to the pixel-dependent projected solid angle !fov,ij .
Figure 7. Temperature courses during the offset calibration regime: (a) temperature sensor signals; (b) mean signal voltage versus the four temperature inputs. The shape of the steady-state curves corresponds to a polynomial of the second or third order. The deviations from these steady-state functions are due to the transient behavior during the temperature change.
NUC can be improved by using more than two raw infrared images and applying the least-squares method to determine the NUC coefcients.
5.3 Gain correction
Here the relation between responsivity and sensor temperature pertaining to Eq. (11) is determined for each pixel and will be taken as the weighting function gV,ij in Eq. (8). According to Eq. (7), different infrared images of two blackbodies with constant temperatures of 20 and 80 C were used.
Since the responsivity depends only on the absolute sensor temperature #fpa and corresponds to a second-order polynomial, it is sufcient to use at least three pairs of infrared images taken at different ambient temperatures. Both blackbodies used (Table 2) cover the entire camera eld of view.
5.4 Offset correction
The offset correction is based on a multivariate linear regression model comprising
polynomials of the second order for each temperature probe inside the camera (Eq. 9), and
one polynomial of the third order for the relation between offset voltage and sensor temperature (Eq. 12).
Since all temperature inputs are correlated with each other due to heat propagation and equalization processes, additional information on the temperature distribution is needed. It can be extracted from the cross-correlation of two or more temperature inputs.
The offset correction function oV,ij in Eq. (10) comprises for instance 17 coefcients if all temperature inputs and all
J. Sens. Sens. Syst., 5, 916, 2016 www.j-sens-sens-syst.net/5/9/2016/
A. Tempelhahn et al.: Shutter-less calibration of uncooled infrared cameras 15
Table 3. Residual uncertainty after offset correction using different numbers and kinds of temperature inputs.
Temperature Residual temporal standard of Residual mean spatial standard Number of inputs deviation t of the mean corrected deviation S of the corrected coefcients pixel signal voltages (gray value) pixel voltages (gray value)
#fpa 541.9 27.9 4 #TP1TP3 46.3 10.5 7
#fpa#TP1TP3 39.8 9.8 10
#fpa#TPm #TPn 37.8 9.3 14
#fpa,#TP1TP3 36.1 9.2 17
#fpa #TP1TP3
#TPm #TPn
possible corresponding cross-correlations are considered:
oV,ij = (14)
c +
3
Xk=1dk#kfpa +3
Xl=12
Xm=1el,m#mTP1 +3
Xn=1fn#fpa #TPn
+g1#TP1 #TP2 + g2#TP1 #TP3 + g3#TP2 #TP3
+g4#TP1 #TP2 #TP3.
As mentioned earlier, all temperature inputs show different temporal behavior, which is used to separate them. An ambient temperature change regime with temperature steps from 5 to 20 K is applied to the camera inside the heat
ing chamber, while the camera looks at a uniform black-body with constant surface temperature. The camera temperature, the sensor temperature as well as other control temperatures were captured periodically. Figure 7 depicts the applied temperature change over time and illustrates the relation of the mean signal voltage in relation to the different temperatures. These relations contain all information about the offset changes due to the ambient temperature change. The coefcients of Eq. (14) were determined by applying the least-square t to a polynomial (Bevington and Keith Robinson, 1992) in the offset calibration data.
Depending on the number and the kind of the used correction inputs, different correction uncertainty values in terms of absolute and spatial deviation can be achieved. Table 3 shows the comparison of different regression models based on the deviation of the mean absolute deviation and the mean spatial standard deviation of the pixel signal voltages over the sensor array. It should be noted that the more correction inputs are used, the lower measurement uncertainty values can be achieved. Figure 8 depicts the mean signal voltage and the spatial standard deviation versus time of the calibration using the offset correction function given by Eq. (14).
5.5 Radiometric calibration
The relation of the signal voltage Voffset,ij after ambient temperature compensation and the observed object temperature #obj can be estimated using a second-order polynomial.
Figure 8. Mean signal voltage and spatial standard deviation of the entire sensor array after offset correction of the calibration data based on 17 correction coefcients. The mean value shows a constant level except for minor peaks when the ambient temperature changes. The spatial level changes slightly depending on the ambient temperature.
The uncertainty due to the regression can be reduced using a Planck-like approximation function based on four coefcients rbf and o,
Voffset,ij =
r
+o, (15)
especially for interpolation outside the supporting points (Budzier and Gerlach, 2015). The inverted function denes the calculation rule to convert signal voltages into temperature values:
#obj,ij =
b
e
(#obj,ij +273.15) f
b
273.15. (16)
www.j-sens-sens-syst.net/5/9/2016/ J. Sens. Sens. Syst., 5, 916, 2016
ln
[parenleftBig]
r Voffset,ij o
[parenrightBig] +
f +
16 A. Tempelhahn et al.: Shutter-less calibration of uncooled infrared cameras
Figure 9. Comparison of the correction of (a) the shutter-less and (b) shutter-based IR cameras for ambient temperature jumps from 25 to 45 C and back. The non-continuous shape of the shutter-based correction is due to the shutter procedure and the thermal drift occurring afterwards. The residual measurement uncertainty of the shutter-less approach is signicantly lower due to the continuous online correction.
6 Comparison of shutter-based and shutter-less correction
The presented correction method for shutter-less IR cameras was compared to the common shutter-based approach using the calibrated IR camera from above and a second equivalent camera with a shutter. The ambient temperature was changed from 25 to 45 C and back. The cameras were facing the same test scene one after another using the four-element blackbody. Figure 9 compares the results of the two measurements of one blackbody with a temperature of 76.6 C.
It should be noted that the residual deviation of the absolute temperatures of the shutter-less camera is signicantly lower than that of the camera with a shutter. Furthermore, due to the fact that there is no interruption of the measurement, the temporal variation is also lower compared to the thermal drift after the shutter procedure.
7 Conclusions
The presented calibration and correction approach for shutter-less and TEC-less microbolometer-based infrared cameras shows very promising results, especially compared with the common shutter-based correction. The main drawbacks are the long calibration time and the huge number of pixel-dependent correction coefcients. This correction is only suitable for measurements with ambient temperature changes that affect the infrared camera almost uniformly. In the next study, the long-term stability of the calibration parameters will be studied.
Acknowledgements. This work was nancially supported by the Deutsche Forschungsgemeinschaft under contract GE 779/26-1.
Edited by: J. HollandtReviewed by: two anonymous referees
References
Bevington, P. R. and Keith Robinson, D.: Data Reduction and Error Analysis for the Physical Sciences, 2nd Edn., McGraw-Hill, New York, 1992.
Budzier, H.: Radiometrische Kalibrierung ungekhlter Infrarot-
Kameras, Habilitationsschrift, Technische Universitt, Fakultt Elektrotechnik und Informationstechnik, Dresdner Beitrge zur Sensorik, TUDpress, Dresden, Band 51, 2014 (in German). Budzier, H. and Gerlach, G.: Thermal Infrared Sensors, Theory, optimisation and practice, Wiley, Hoboken, NJ., USA, Chichester, UK, 2011.
Budzier, H. and Gerlach, G.: Calibration of uncooled thermal infrared cameras, J. Sensors and Sensor Systems, 4, 187197, 2015.
Hoelter, T., Kathman, A., Richards, A., and Walters, M.: Key Technology Trends and Emerging Applications for Compact Thermal Imagers, AMA Conferences 2015, Nrnberg, Germany, 1921 May 2015, 938943, doi:http://dx.doi.org/10.5162/irs2015/4.1
Web End =10.5162/irs2015/4.1 http://dx.doi.org/10.5162/irs2015/4.1
Web End = , 2015.
Moreno, M., Torres, A., Kosarev, A., and Ambrosio, R.: Un-Cooled Microbolometers with Amorphous Germanium-Silicon (a-GexSiy:H) Thermo-Sensing Films, in: Bolometers, edited by:
Unil Perera, A. G., INTECH Open Access Publisher, Chapter 2, doi:http://dx.doi.org/10.5772/32222
Web End =10.5772/32222 http://dx.doi.org/10.5772/32222
Web End = , 2012.
Takasawa, S.: Uncooled LWIR imaging: applications and market analysis, Proc. SPIE, 9481, doi:http://dx.doi.org/10.1117/12.2183027
Web End =10.1117/12.2183027 http://dx.doi.org/10.1117/12.2183027
Web End = , 2015. Tempelhahn, A., Budzier, H., Krause, V., and Gerlach, G.: Modeling signal-determining radiation components of microbolometer-based infrared measurement systems, AMA Conferences 2013, Nrnberg, Germany, 1416 May 2013, 100104, doi:http://dx.doi.org/10.5162/irs2013/iP3
Web End =10.5162/irs2013/iP3 http://dx.doi.org/10.5162/irs2013/iP3
Web End = , 2013.
Tempelhahn, A., Budzier, H., Krause, V., and Gerlach, G.: Development of a shutterless calibration process for microbolometer-based infrared measurement systems, The e-journal of Nondestructive Testing, 20, ISSN 1435-4934, 2015.
Tissot, J. L., Robert, P., Durand, A., Durand, S., Durand, E., and Crastes, A.: Status of uncooled infrared detector technology at ULIS, France, Defence Sci. J., 63, 545549, 2013.
J. Sens. Sens. Syst., 5, 916, 2016 www.j-sens-sens-syst.net/5/9/2016/
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Copyright Copernicus GmbH 2016
Abstract
Infrared (IR) cameras based on microbolometer focal plane arrays (FPAs) are the most widely used cameras in thermography. New fields of applications like handheld devices and small distributed sensors benefit from the latest sensor improvements in terms of cost and size reduction. In order to compensate for disturbing influences derived from changing ambient conditions, radiometric cameras use an optical shutter for online recalibration purposes, partially also together with sensor temperature stabilization. For these new applications, IR cameras should consist only of infrared optics, a sensor array, and digital signal processing (DSP). For acceptable measurement uncertainty values without using an optical shutter (shutter-less), the disturbing influences of changing thermal conditions have to be treated based on temperature measurements of the camera interior. We propose a compensation approach based on calibration measurements under controlled ambient conditions. All correction parameters are determined during the calibration process. Without sensor temperature stabilization (TEC-less), the pixel responsivity is also affected by the camera temperature changes and has to be considered separately. This paper presents the details of the compensation procedure and discusses relevant aspects to gain low temperature measurement uncertainty. The residual measurement uncertainty values are compared to the shutter-based compensation approach.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer