Full text

Turn on search term navigation

© 2016 Berisha et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Purpose

To develop a robust T magnetic resonance imaging (MRI) sequence for assessment of myocardial disease in humans.

Materials and Methods

We developed a breath-held T mapping method using a single-shot, T-prepared balanced steady-state free-precession (bSSFP) sequence. The magnetization trajectory was simulated to identify sources of T error. To limit motion artifacts, an optical flow-based image registration method was used to align T images. The reproducibility and accuracy of these methods was assessed in phantoms and 10 healthy subjects. Results are shown in 1 patient with pre-ventricular contractions (PVCs), 1 patient with chronic myocardial infarction (MI) and 2 patients with hypertrophic cardiomyopathy (HCM).

Results

In phantoms, the mean bias was 1.0 ± 2.7 msec (100 msec phantom) and 0.9 ± 0.9 msec (60 msec phantom) at 60 bpm and 2.2 ± 3.2 msec (100 msec) and 1.4 ± 0.9 msec (60 msec) at 80 bpm. The coefficient of variation (COV) was 2.2 (100 msec) and 1.3 (60 msec) at 60 bpm and 2.6 (100 msec) and 1.4 (60 msec) at 80 bpm. Motion correction improved the alignment of T images in subjects, as determined by the increase in Dice Score Coefficient (DSC) from 0.76 to 0.88. T reproducibility was high (COV < 0.05, intra-class correlation coefficient (ICC) = 0.85–0.97). Mean myocardial T value in healthy subjects was 63.5 ± 4.6 msec. There was good correspondence between late-gadolinium enhanced (LGE) MRI and increased T relaxation times in patients.

Conclusion

Single-shot, motion corrected, spin echo, spin lock MRI permits 2D T mapping in a breath-hold with good accuracy and precision.

Details

Title
Measurement of Myocardial T1ρ with a Motion Corrected, Parametric Mapping Sequence in Humans
Author
Berisha, Sebastian; Han, Joyce; Shahid, Mohammed; Han, Yuchi; Witschey, Walter R T
First page
e0151144
Section
Research Article
Publication year
2016
Publication date
Mar 2016
Publisher
Public Library of Science
e-ISSN
19326203
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
1775161696
Copyright
© 2016 Berisha et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.