Lapinsky et al. Intensive Care Medicine Experimental 2015, 3(Suppl 1):A275 http://www.icm-experimental.com/content/3/S1/A275
POSTER PRESENTATION Open Access
Obstetric delivery in mechanically ventilated critically ill pregnant women
SE Lapinsky1,2*, JA Rojas-Suarez3,4, TM Crozier5, DN Vasquez6, N Barrett7, G Bourjeily8,9
From ESICM LIVES 2015Berlin, Germany. 3-7 October 2015
Introduction
Approximately 1 in 500 pregnancies develop complications requiring mechanical ventilatory support, the majority of episodes occurring postpartum. While uncommon, the situation of a pregnant woman requiring ventilatory support for respiratory failure is very concerning. Delivery of the fetus is often considered, either to improve maternal well-being or due to concerns for the fetus. Little data exist to guide physicians in these decisions.
Objectives
To evaluate the effect of obstetric delivery on maternal respiratory function, in pregnant women ventilated for respiratory failure.
Methods
Subgroup analysis of a retrospective review of pregnant women from 4 ICUs in 4 countries over a 10 year period, who received mechanical ventilation for greater than 24 hours. In women who delivered while on mechanical ventilation, maternal respiratory parameters were evaluated pre-delivery and 2-5 hours and 12-15 hours post-delivery. Respiratory system compliance was estimated from recorded ventilator plateau pressure and tidal volume. Data are presented as median and interquartile ratio (IQR).
Results
We identified nine women who delivered while ventilated for respiratory failure. Median age was 29 (22.5-33.5) years and gestation 29 (27.5-31) weeks. Pre-delivery Pa02/Fi02 ratio was 268 (131-317) and PaC02 37.3 (33.2-49) mmHg. Duration of ventilation prior to delivery was 1.5 (1-2) days, and time from delivery to extubation was 2 (1-3.8) days. All deliveries were by Cesarean section except one
spontaneous stillborn delivery at 26 weeks. Cesarean sections were performed for either maternal respiratory indications (n = 3) or for obstetric/fetal indications (n = 5). APGAR scores at 1 minute were low (7) in all 8 elective deliveries, and only 3 recovered to >7 by 5 minutes. All mothers survived, as did all but one neonate (the spontaneous delivery).
Delivery had a variable effect on maternal respiratory parameters. By 12-15 hours, oxygenation index had improved from a median 7.5 (5.9-16.2) to 6 (4.9-9.1), and PEEP was reduced from 11 cmH2O (8.5-12) to 9 cmH2O(6.5-10). Estimated compliance improved in most patients, but to a variable degree. Three hypercapnic patients (mean C02 57 mmHg) improved, to mean PaC02 of 46 mmHg.
Conclusions
This relatively small case series examines a rare but important intervention in the ICU - delivery of the fetus in a pregnant woman ventilated for respiratory failure. Delivery occurred early in the mothers ventilator course, followed by extubation within a few days in the majority of patients. The effect of delivery on maternal respiratory function was variable, with some, but not all women showing an improvement in oxygenation and respiratory system compliance. At delivery, fetal compromise was evident but all neonates survived to hospital discharge.
Authors details
1Mount Sinai Hospital, Toronto, Canada. 2University of Toronto, Interdepartmental Division of Critical Care Medicine, Toronto, Canada.
3Gestion Salud Clinic, Intensive Care Unit, Cartagena, Colombia. 4Universidad de Cartagena, Grupo de Investigacin en Cuidados Intensivos y Obstetricia, Cartagena, Colombia. 5Monash Medical Centre, Intensive Care Unit, Clayton, Australia. 6Sanatorio Anchorena, Buenos Aires, Argentina. 7Monash Medical Centre, Department of Obstetrics & Gynaecology, Clayton, Australia. 8Warren Alpert Medical School of Brown University, Pulmonary and Critical Care Medicine, Providence, RI, United States. 9The Miriam Hospital, Providence, RI, United States.
1Mount Sinai Hospital, Toronto, CanadaFull list of author information is available at the end of the article
2015 Lapinsky et al.; This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0
Web End =http:// http://creativecommons.org/licenses/by/4.0
Web End =creativecommons.org/licenses/by/4.0 ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Lapinsky et al. Intensive Care Medicine Experimental 2015, 3(Suppl 1):A275 http://www.icm-experimental.com/content/3/S1/A275
Page 2 of 2
Published: 1 October 2015
doi:10.1186/2197-425X-3-S1-A275Cite this article as: Lapinsky et al.: Obstetric delivery in mechanically ventilated critically ill pregnant women. Intensive Care Medicine Experimental 2015 3(Suppl 1):A275.
Submit your manuscript to a journal and benet from:
7 Convenient online submission7 Rigorous peer review7 Immediate publication on acceptance7 Open access: articles freely available onlihttp://www.springeropen.com/
Web End =ne 7 High visibility within the eld7 Retaining the copyright to your article
Submit your next manuscript at 7 http://www.springeropen.com/
Web End =springeropen.com
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
The Author(s) 2015
Abstract
Issue Title: ESICM LIVES 2015
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer