,
Collagen is the most abundant protein in the extracellular matrix, and plays a central role in the formation of brillar structures in connective tissues1. Collagen molecules exhibit a triple helical structure and, in most collagen types (brillar collagens), self-assemble into brils 10300 nm in diameter and up to several hundreds of m in length. Collagen brils are found in a wide variety of tissues such as bone, tendon, skin, ligament, cornea and internal organs. Fibrils further assemble into higher order tissue-specic structures, such as bundles or bers. Proper macromolecular organization of collagens is crucial for the organs architecture and function. However, extracellular matrix remodeling may occur in tissues in response to various injuries, and in most cases, it exhibits abnormal accumulation of brillar collagen. This process is called brosis and eventually leads to organ functional failure. Implementation of reliable brosis indexes is currently much needed to better understand the mechanisms regulating collagen remodeling. In the past decade, second harmonic generation (SHG) microscopy has emerged as a promising direction to implement brosis assays, since brillar collagens intrinsically exhibit strong SHG signals25. SHG microscopy is a three-dimensional (3D)-resolved laser scanning technique where a tightly focused Gaussian beam is scanned across the sample while SHG signals are recorded. At the molecular scale, the second harmonic response of collagen originates from the nonlinear polarization of non-centrosymmetric peptide bonds along the collagen triple helix. At the scale of the diraction-limited probe volume, the signal scales as the square number of aligned peptide bonds within the micron-sized scanned probe volume68. Collagen SHG is therefore label-free, specic and sensitive, which makes it a good candidate for systematic studies based on brosis scoring911 in histological sections with better reliability than conventional staining-based techniques.
However the generalization of this approach is hampered by the fact that histological sections generally exhibit inhomogeneous thickness and poor atness, so that SHG-based probing with a point-scanning system requires time-consuming 3D scans. In addition, it is difficult to derive a quantitative interpretation of 3D SHG image
Palaiseau cedex, France. dHres, France. Laboratory of condensed matter physics, Ecole polytechnique, CNRS, Universit Paris-Saclay, Paris-Cardiovascular Research Centre, INSERM, European Georges Pompidou [email protected])
R A
P
SCIENTIFIC REPORTS
1
www.nature.com/scientificreports/
stacks in terms of collagen density, since the contrast mechanism is coherent while the scanning process is not. One workaround could be to extend the depth-of-eld of the microscope by using a weakly focused excitation Gaussian beam to remove the need for an axial scanning12, but this solution necessarily limits the lateral resolution of the image and reduces its information content. There is a need for images revealing both the brosis microstructure and its extent over scales of several millimeters. In this context, Bessel beam excitation, recently proposed for multiphoton microscopy applications1316, appears as an interesting alternative to Gaussian beam excitation in SHG microscopy of tissue sections. Indeed, a focused Bessel beam can in principle provide a nonlinear probe volume with an axial extension encompassing the thickness and height heterogeneity of a histological section (i.e. several microns or several tens of microns), and a conned lateral extension enabling to probe the sample lateral organization. However the use of Bessel beams for second-harmonic generation imaging has not been precisely described so far.
In this article, we analyze and demonstrate the use of Bessel beam excitation for extended-depth SHG imaging of thick samples. We rst describe the production of Bessel beams with adjustable properties in a scanning multiphoton microscope. We then demonstrate extended depth SHG-2PEF imaging of brotic mouse kidney biopsy samples. Finally, we analyze more precisely the imaging properties of Bessel beams for SHG and two-photon-excited uorescence (2PEF) microscopy in terms of signal level and emission directionality as a function of sample geometry. Overall, these results show how Bessel beam excitation can be used to probe collagen accumulation more rapidly and more reliably than the usual Gaussian excitation scheme.
Bessel beams. Bessel beams are a class of beams that were rst introduced by Durnin et al. in 19871719 and that exhibit an invariant intensity distribution along their propagation axis, producing a needle of light of innite extension. Such an ideal Bessel beam is dened by the following equation:
E r z J kr exp ikz
( , ) ( sin( )) ( cos ), (1)
0
where J0 is the 0-order Bessel function of the rst kind, r is the distance from the optical axis in a transverse plane, z is the propagation distance along the optical axis, k is the wave vector and the angle between the optical axis and the wave vectors forming the Bessel beam (see Supplementary gure S1). A Bessel beam is obtained when focusing an innitely thin ring. However it should be noted that, similarly to plane waves, ideal Bessel beams carry an innite amount of energy and cannot be created experimentally. Instead, Bessel-like beams having a nite axial extension can be created using a phase generator such as a spatial light modulator (SLM), as described in the Methods section. This approach results in an intensity distribution near the optical axis that scales as20,21:
2 2 2
I r z z zz J
( , ) 4 exp 2 2 4048 ,
2 0
max
z cos /sin
max 0 correspond to the lateral and axial full-width-at-half-maximum (FWHM) of the intensity distribution. Here the lateral and axial extensions r0 and zmax can be controlled independently by two experimental parameters, namely the waist of the incident Gaussian beam, 0, and the slope of the phase modulator that determines .
The combination of a beam expander and a SLM thus permits to program independently the lateral and axial extension of the focused Bessel beams through the control of the incident beam size illuminating the SLM and the propagation angle of the cone of light refracted by the SLM. As such, using a phase SLM is particularly interesting for implementing Bessel beams as it paves the way to programmable Bessel beam excitation for multiphoton microscopy.
Figure1 shows experimental point spread functions (PSF) measured in our microscope (see Supplementary gure S2) of Bessel beams with independent lateral and axial extensions. These results are in good agreement with the expected intensity distribution (Fig.1 le) calculated as explained in the Methods and Supplementary gure S3. They illustrate the versatility of our design: the depth of eld can be enhanced without compromising the lateral resolution of the point scanning microscope.
It should be noted however that depth-of-eld extension generally comes at the price of an increase in background due to the Bessel beam secondary rings (see Supplementary information), and a decrease in excitation intensity in the main lobe if the total power of the beam is kept constant. This is illustrated in Fig.1 and Supplementary figure S4: elongated PSFs exhibit a reduced peak intensity in the main lobe, resulting in a decreased nonlinear excitation efficiency. Moreover, axial extension also correlates with the increase in intensity in side lobes of the PSF (as visible on XY proles and Supplementary gure S4) that induces a blur in the images obtained with such excitation. Although this blur is reduced in the case of nonlinear imaging, these two eects limit the maximum axial extension that can eectively be used for nonlinear imaging.
Second-harmonic generation imaging with Bessel beam excitation. Figure2 shows SHG images of the same objects recorded with Bessel and Gaussian excitation and their corresponding intensity proles. The axial and lateral full-width-at-half-maximum of the main excitation lobe as estimated using Gaussian ts of imaging data were 7 m 0.3 m for Bessel excitation and 0.7 m 0.26 m for Gaussian excitation. These data conrm that the lateral resolution in the case of sparse samples corresponds to the extent of the main lobe in the case of Bessel excitation which is consistent with results previously reported in the case of 2PEF imaging with Bessel beams13.
r k
2 4048/( sin )
0 and
=
=
2
.
r r
0
(2)
where
= .
SCIENTIFIC REPORTS
2
www.nature.com/scientificreports/
Figure 1. Programmable Bessel beam excitation. The gure shows the axial and transverse square intensity distribution of beams used in this study (le, simulations; right, camera-based measurements). The wavelengths and FWHM extension of the main lobe of the focused beam correspond to, from top to bottom: (A) (Gaussian)
=1100nm, 1.4m0.3m; (B) =1100nm, 7m0.2m; (C) =1100nm, 14m0.3m; (D) =1100nm, 23m0.56m; (E) =850nm 23m0.2m. Proles (bottom) are plotted along the white dotted line. Square intensity scaling factors are indicated for experimental Bessel beams obtained with the same objective and wavelength.
Let us now analyze the ability of Bessel beams to deliver extended depth of eld coherent nonlinear imaging. Figure3AC shows extended depth of eld SHG imaging of a 15m-thick mouse kidney biopsy sample. Images were recorded with a 60 1.2 NA water immersion objective (Olympus) and at 800 nm excitation wavelength. Only o-axis SHG signal was collected in the case of Bessel excitation, for reasons discussed in the last section of this article. Collagen brils present in the imaged volume can be detected in a single Bessel image, while a Z-series of 15 images spaced by 0.5m is needed when using Gaussian excitation with similar lateral resolution. The pixel integration time used here was 3 times longer in the case of Bessel excitation, so that the imaging process was 5 times faster. Overall, these data illustrate that Bessel beams can be used to rapidly probe the SHG response of a thick sample, at the cost of losing axial resolution.
Importantly for applications to brosis scoring, the signal detected during Bessel SHG imaging results from constructive interference of harmonic light scattered over the entire axial extent of the probe beam. This implies that the signal is eectively proportional to the square number of aligned harmonophores within the probe beam. This is essentially dierent from the case of probing a thick sample with Gaussian beams focused at successive depths, and then performing an incoherent summation of the images. In this case, the resulting contrast depends on axial sampling. Hence, Bessel beam excitation provides a dierent contrast mechanism. When probing a single bril or several brils with the same polarity, the Bessel SHG signal is expected to scale quadratically with the density of collagen molecules. In practice, we observed in kidney histological sections that Bessel SHG highlights the most concentrated (or brotic) regions in the sample. This is exemplied in Fig.3DF showing the SHG contrast dierence between Gaussian and Bessel excitation. Bessel and summed Gauss images were normalized in order to have equivalent levels from structures producing the smallest signals in both images. The ratio of Bessel-to-Gaussian signals and the corresponding pixel histogram are displayed in Fig.3F, and illustrate how regions with thick brillar structures are highlighted in the Bessel image. We point out however that the quadratic dependence will be lost in samples where collagen bril polarity is heterogeneous at the submicron scale such as cartilage, as recently analyzed by interferometric SHG (I-SHG) studies22. In such organizations, it remains very complex to relate SHG intensity to collagen density. Nevertheless, as suggested by Fig.3F, extended-depth excitation does highlight brotic regions in kidney biopsy sections, presumably because brils exhibit constant polarity over thicknesses reaching several microns in this type of tissue.
Application to extended depth of eld imaging of non-at biopsy sections. We now demonstrate the potential of nonlinear imaging with Bessel beams for rapid probing of brotic collagen accumulation in thick histological sections. Using 23m0.3m Bessel excitation, we recorded simultaneous SHG-2PEF images of an entire section of brotic mouse kidney (Fig.4 and supplementary movie). SHG was detected in the forward direction with a spatial lter selecting o-axis emission (see next section), and 2PEF was backward-detected.
The entire image spans approximately 5 5.5mm2 and was assembled from 1819 tiles recorded with 40% surface overlap for simplifying subsequent stitching, and 0.5m lateral pixel size. In order to detect both small and large signals without saturation, we used a pixel dwell time of 30s. Overall, the total exposure time was here
SCIENTIFIC REPORTS
3
www.nature.com/scientificreports/
Figure 2. Lateral extension of the SHG images of small objects images with Bessel and Gaussian excitation.
150nm KTP nanocrystal (A) and collagen ber (B) imaged with Bessel (top) and Gaussian (bottom) excitation. Bessel signal was collected o-axis. Bessel beam dimensions: 7m0.3m. Excitation wavelength: 1100nm. Pixel dwell times: (A, Bessel) 20s; (A, Gauss) 9s; (B, Bessel) 25s; (B, Gauss) 50s.
1 h 17 min for 154 000 000 pixels. We note that this acquisition time could be signicantly reduced by using a smaller pixel dwell time (e.g. when detecting only large signals) and less overlap. Recording a Gaussian excitation image with similar lateral resolution and depth of eld would have typically taken 10 times longer. The uorescence image (shown in red) reveals the general morphology of the kidney, while the SHG image highlights brillar collagen.
As discussed in previous paragraphs, this imaging strategy provides data that are simpler to relate to collagen density than when using a 3D scanning scheme, since the Bessel SHG signal is proportional to the square number of in-plane collagen molecules. Note however that the collagen density may be underestimated because of partially destructive interference when collagen brils with anti-parallel orientations lie together within the extended focal volume22. A tentative map of the brillar collagen content in the sample can be obtained by taking the square root of the SHG image, as illustrated on the black radial prole in Fig.4C. Alternatively, extracting a prole of the SHG signal (instead of its square root) as shown as a red prole in Fig.4C highlights the brotic areas. This kidney SHG radial prole reveals that brosis develops around the arcuate arteries in the deep cortex of the kidney, in agreement with previous studies5,23, as well as in the renal medulla in the brosis model considered here (see Methods). These data illustrate that brosis scores can be derived from Bessel SHG images.
As explained in the introduction, the application of SHG microscopy for collagen scoring in brotic tissue samples requires to record extended-depth volumes because of the non-atness of tissue biopsy samples and of the heterogeneity of collagen accumulation in broses. Our acquisition scheme has therefore practical advantages over the Gaussian-based approach. The acquisition of mosaic such as the one shown in Fig.4 is faster for a given probed volume and lateral resolution. It is therefore easier with Bessel excitation to maintain mechanical stability and proper objective immersion during the imaging process. In turn, mosaic high resolution stitching can be successfully automated using standard algorithms24.
Overall, these data show that Bessel excitation enables an important step towards the development of systematic SHG-based diagnostics. In the next section, we analyze more precisely the physics of Bessel SHG microscopy signals.
Signal variation with extended beam for coherent and incoherent processes. In order to investigate the physics of SHG with Bessel excitation, we consider in this section 2PEF and SHG signal levels as a function of Bessel beam axial extension, in the case of point-like and extended objects. We rst discuss simple scaling arguments and corroborate them with experiments, and in the subsequent section of this article we will discuss more precisely SHG phase matching with Bessel beams.
As pointed out earlier, the energy carried by the main lobe of the Bessel beam decreases in proportion to its axial extension: in the case of a Bessel beam25,26, when the central lobe is extended axially by a factor z while keeping constant its lateral extension and the average laser power, the energy in the central lobe varies as 1/z.
Therefore, the signal from a point-like object is expected to decrease as
1/ z
2 in the case of a two-photon process.
In the case of an axially extended object, the eect of beam shaping on signal level depends on whether an incoherent (e.g. uorescence) or coherent (e.g. harmonic generation) contrast mechanism is used. In the case of 2PEF if we make the simplifying assumption that only the main lobe contributes to the excitation, the total signal is proportional to the illuminated volume times the excitation intensity squared and should scale as 1/z (=z
1/ z
2).
Interestingly, in the case of SHG, if all contributions scattered by the sample along the optical axis interfere in a constructive manner, the signal should scale as (z1/z2), i.e. should not exhibit the same drop as 2PEF from an extended sample (Table1).
SCIENTIFIC REPORTS
4
www.nature.com/scientificreports/
Figure 3. SHG microscopy with axially extended depth of eld. (AC) Images of collagen bers within a 15m thick histological section of mouse kidney were recorded with Gaussian (0.7 m0.3m) and Bessel (7m0.3m) excitations (800nm). (A,B) Gaussian 2D images recorded at dierent depths. (C) 2D imageof the same eld recorded with Bessel excitation. (DF) Comparison of SHG imaging contrast using Besseland Gaussian excitations. (D) image of collagen bers with 3D-scanned Gaussian excitation (0.7m0.3m) and sum projection of a Z-series. (E), corresponding eld recorded with 2D-scanned Bessel excitation (23m0.3m) and o-axis detection. (F) Ratio of Bessel-to-Gaussian images calculated assuming similar signals for the smallest bers. The corresponding histogram is shown on the right. Values superior to 1 reect the coherent enhancement obtained with extended-depth Bessel excitation. Pixel dwell times, excitation powers aer the objective, and maximum signal levels: (A,B) 65s, 43mW, 250 photons; (C) 330s, 35mW, 70 photons; (D) 5s *20, 12mW, 250 photons/plane; (E) 20s, 45mW, 230 photons.
To experimentally validate these predictions, we recorded SHG and 2PEF signals from point-like and extended objects using Bessel beam excitation (Fig.5). We used two shapes of Bessel beams exhibiting comparable lateral extension and dierent axial extensions 1 and 2 (Fig.5A). We characterized the intensity distribution of the two excitation Bessel beams using the setup described in Supplementary gure S2: we measured the ratio between square intensities in the main lobes in the plane of focus (z=0) to be I02(2)/I02(1)=0.500.05, and the ratio between integrated intensities at z = 0 taking into account the rst 10 secondary rings to be Ifull2(2)/Ifull2 (1)=0.70.1.
As a model for point-like objects, we chose samples smaller than the axial extent of our excitation beams, namely 1m diameter uorescently-labelled polystyrene beads for 2PEF and 150nm diameter KTP nanoparticles for SHG. As models for axially extended 2PEF and SHG samples, we recorded signal from a liquid bodipy solution sealed between two glass coverslips and from potato starch granules, respectively.
As summarized in Fig.5, we found that the signal ratio S(2)/S(1) was 0.500.03 in the case of small objects for both 2PEF and SHG cases. These measurements are consistent with the measured squared intensities of the excitation beams and the predictions given in Table1, and conrm that depth-of-eld extension has an important cost on 2PEF and SHG signal level from small objects. In contrast, we measured a ratio of 0.85 0.03in the case of an extended uorescent sample, and of 2.0 0.5 in the case of an axially extended harmonic generator (i.e. the SHG signal in this case increased with beam extension). These observations conrm that, in contrast with
SCIENTIFIC REPORTS
5
www.nature.com/scientificreports/
Figure 4. Extended-depth SHG-2PEF imaging of a brotic kidney histological section (see also Supplementary movie). (A) 15m thick histological section of brotic mouse kidney was imaged with Bessel excitation (800nm, 23m0.2m) and XY mosaicking. (A) Stitched 2D Bessel image of the entire histological section. SHG signal is shown in blue and endogenous 2PEF is shown in red. Imaged area: 55.5m2. Lateral pixel size 0.50.5m2. Pixel dwell time, 30s. Power aer objective, 45mW. Signal level up to 250 photons/pixel. Scale bar, 1mm. (B) Zoomed-in area showing the local SHG and 2PEF contrasts. Scale bar, 50m. (C) Integrated radial proles of the SHG signal (red) and of the square root of the SHG signal (black).
Point-like object Axially extended object
2PEF
1/ z
2 1/z2z=1/z SHG
1/ z
2 (z1/z2)=1
Table 1. Expected signal variation as a function of Bessel beam axial extension z for incoherent and coherent two-photon processes.
uorescence, harmonic generation with Bessel beams occurs coherently over the extent of the beam, so that large SHG signals may be observed from large objects despite reduced excitation intensity. These results suggest that
SCIENTIFIC REPORTS
6
www.nature.com/scientificreports/
Figure 5. 2PEF and SHG signal level for point-like and axially extended objects as a function of Bessel beam extension . (A) Excitation PSF2 (square intensity distribution) estimated from camera-based measurements. Bessel beams parameters: 1100nm, NAB=1.05, 7m0.3m and 14m0.3m extensions.
(B) Images of point-like (150nm KTP crystal and 1m uorescent polystyrene beads) and axially extended objects (Starch granule and 5% bodipy solution) recorded with the two beams. Pixel dwell times: bead, 20 s; KTP, 10s; bodipy, 5s; starch, 50s. (C) Ratio between the signals obtained with the two beams for 2PEF and SHG, and for each type of sample.
the extended depth of eld properties of Bessel beams may be used for rapidly probing nonlinear properties of thick samples when using coherent signals. In the next section, we will analyze more specically the signal generation mechanisms for SHG imaging.
Phase matching and directionality. Because SHG is coherent, its efficiency and directionality depend both on sample structure and on excitation eld distribution. SH radiation efficiency in a particular direction is governed by wave vector mismatch in that direction. The wave vector mismatch k between the driving and harmonic elds in a direction is given by the geometrical projection of k(2) 2k() along that direction. If we consider the case of a non-dispersive medium for simplicity, with Bessel excitation characterized by an angle (Supplementary gure S1), efficient second-harmonic emission occurs along direction , for which wave mismatch is minimal i.e. coherence length is maximal. Alternatively, on-axis emission is characterized by a coherence length Lc=/k0/(2k(1cos)) (see the schematics in Fig.6).
To provide a more complete picture of the emission directionality, we performed numerical simulations of SHG emission directions by a sample of dierent thicknesses illuminated by a Bessel beam. The simulations followed the approach described in27 for the case of third-harmonic generation. A vector eld model was used for the excitation eld focused in representative conditions ( = 1100 nm, NABessel = 0.8 0.1, n = 1.33, no disper
sion). A model sample geometry was considered, corresponding to the simple case of a semi-innite slab with congurable thickness transverse to the propagation axis. The sample was considered to be a monocrystal characterized by a unique tensor element xxx(2) with x the polarization direction of the incident beam. Figure6B shows the calculated emission directions as a function of sample thickness. The simulations corroborate the considerations on phase matching directions. For sample thicknesses up to 710 m in these conditions, o-axis SHG exhibits a quadratic dependence on sample thickness, whereas on-axis SHG exhibits an oscillating behavior. The detection of o-axis SHG is therefore expected to provide an extended-depth image resulting from the coherent
SCIENTIFIC REPORTS
7
www.nature.com/scientificreports/
Figure 6. Scattering directions of SHG with Bessel beam excitation. (A) Phase-matching as a function of SHG scattering direction. (B) Top le, numerical simulations of SHG from a slab sample centered at focus as a function of sample thickness and emission direction. O-axis emission increases with sample thickness in this range owing to good phase matching. Near-axis scattering efficiency oscillates with sample thickness. Bottom right, far-eld emission diagrams for sample thicknesses of 3m and 6m. Right, integrated SHG as a function of sample thickness shown in linear and logarithmic scales, for dierent ranges of detection NAs: near-axis scattering (red), o-axis scattering (yellow), and total scattering (blue). O-axis SHG scales as the square of sample thickness up to approximately 10m. Simulation conditions: =1100nm, NAB=0.80.1, n=1.33, no dispersion. (C) SHG images of collagen bers recorded with Bessel excitation (800nm, NAB=1) and angular ltering in the detection path. Signal was successively recorded with the following conditions (from le to right): detection in all angular directions with NAdet ranging from 0 to 1.2; detection of o-axis SHG with NAdet ranging from 0.6 to 1.2; detection of near-axis SHG with NAdet ranging from 0 to 0.2 and tripled acquisition time.
superposition of the contributions of all the dipoles excited in the probe volume. Alternatively, the detection of on-axis SHG provides an image characterized by a coherence length shorter than the axial extent of the Bessel beam, i.e. containing intensity artifacts related to the local thickness and axial structure of the probed sample2730.
We experimentally validated these predictions by recording transmission SHG images with spatially ltered emission directions (Fig.6C). We recorded images of the same samples either without ltering, or by blocking the near-axis emission with a mask, or by blocking the o-axis emission with a diaphragm. The emission spatial lter was calibrated by measuring the transmission of Bessel beams of known numerical aperture (NA). We then recorded SHG images of brillar collagen in a 15-m thick histological section of brotic mouse kidney. The results are displayed in Fig.6, and the following observations can be made: (i) Bessel SHG is predominantly scattered o-axis; (ii) detection of on-axis or o-axis SHG results in images exhibiting dierent contrast. The on-axis image exhibits some hot spots not present in the o-axis image. Following our analysis, the interpretation of these data is that the o-axis image can be viewed as the actual extended depth of eld SHG image, while the near-axis image contains intensity variations related to the interplay between the axial spatial frequencies of the sample and the on-axis coherence length associated with the Bessel beam.
Bessel beam excitation is an eective approach for increasing the depth-of-eld while maintaining lateral resolution in point scanning microscopy. In this work we have analyzed and demonstrated the use of Bessel beam excitation specically for SHG imaging, i.e. a coherent nonlinear process. Considering collagen imaging, we have shown that strong Bessel SHG signals are observed in dense collagen regions owing to coherence over the axially extended probe volume, despite the reduction in excitation intensity involved by beam shaping. When combined with spatially ltered detection and 2D scanning, this technique is an eective means for probing collagen accumulation in histological sections. This approach has two advantages compared to the usual imaging scheme relying on 3D scanning of a tightly focused Gaussian beam.
SCIENTIFIC REPORTS
8
www.nature.com/scientificreports/
Firstly, the Bessel SHG signal is proportional to the square number of collagen molecules with parallel orientation within the focal plane assuming constant molecular polarity within the excitation volume, which seems to be veried for brotic tissues. Signals therefore have a simpler relation to collagen density than when using a 3D scanning scheme. A meaningful map of the brillar collagen content in brotic samples can be deduced from the Bessel SHG image, opening the way to brosis scoring. In addition, our analysis of the contrast mechanisms involved in Bessel SHG microscopy shows how spatial ltering of the detection should be used to select the signal corresponding to coherent extended depth of eld emission. We note however that the quadratic relation between SHG and collagen density is lost in samples where collagen bril polarity is heterogeneous at the submicron scale22. In such organizations, it remains very complex to relate SHG intensity to molecular density. Although this is beyond the scope of the present study, we note that for that purpose, Bessel excitation with adjustable depth-of-eld can provide a novel contrast mechanism for analyzing collagen macromolecular organization, complementary to I-SHG and polarization-resolved SHG.
Secondly, as also illustrated in this work, the acquisition time needed to probe a histological section can be signicantly reduced with Bessel excitation. An extended depth of eld is needed to probe histological sections over several mm2 due to their poor atness. Faster imaging and 2D scanning are advantageous as they mitigate issues associated with mechanical stability and 3D image stitching. We also note that the Bessel acquisition scheme could be further optimized for fast scanning of histological samples by using a more efficient phase modulator such as a static diractive phase mask13, a laser source with higher peak power, and multipoint excitation.
Bessel excitation appears to be well suited for rapidly probing non-at thin samples such as most tissue biopsy samples while preserving lateral resolution. Overall, this study paves the way to the development of systematic SHG-based assays for large-scale physiopathological studies.
Imaging was performed on a lab-built multiphoton point-scanning microscope constructed around an inverted frame (Olympus IX-70). The output beam from a Titanium-sapphire oscillator (6901090nm, 80MHz, 150fs, Chameleon Ultra 2, Coherent, USA) or an optical parametric oscillator (10001400 nm, 80 MHz, 350 fs, compact OPO, Coherent, USA) was sent though a variable beam expander (S6EXZ5076/328, Sill Optics) and then shaped into an annular intensity distribution using a reective liquid crystal spatial light modulator (LCoS-SLM X10468, Hamamatsu, Japan) and a lens (Supplementary gure S2). The zeroth diraction order was rejected aer a focusing lens by incorporating a tilt on the SLM pattern and a blocking mask in the Fourier plane (see31 ). The transmission of the shaping module was approximately 72% at 1100 nm and 60% at 840 nm. The shaped beam was angularly scanned at the back pupil plane of the microscope objective by two conjugated galvanometric mirrors (VM500+, GSI, USA). This conguration produces an annular intensity distribution of light on the scanning mirrors and at the back pupil of the excitation objective, and a Bessel beam at its focus. Two water immersion objectives were used to focus the excitation beams in the sample: a 251.05NA XLPlanN and a 601.2NA UPlanSApo. Excitation intensity was controlled with a wave plate and a polarizer. Nonlinear signals were separated from the excitation light with appropriate lters (Semrock 400/20 for SHG and 475/64 for 2PEF), and detected in the epi- or trans- directions by photomultiplier tubes (SensTech, UK) and lab-designed photon counting electronics. Scanning and acquisition were synchronized using a custom LabVIEW program and a multichannel I/O board (PCI-6115, National Instruments, USA).
To measure the excitation point spread functions (PSF), we added a characterization module29,30 consisting of a removable 50/50 beam splitter, a tube lens (F =300mm) and a CCD camera (AVT Stingray F-125B). 3D PSFs were measured by scanning axially a silver-coated mirror across the focal plane.
We note that implementing a telecentric arrangement for the scanning system, i.e. ensuring that the two scanning mirrors are conjugated with the objective back aperture, is important to minimize aberrations and PSF tilting during the scan. With the 25 objective, this conguration resulted in a usable eld of view larger than 400m where Bessel excitation was properly shaped and parallel to the optical axis (Supplementary gure S2).
We also note that, as in the case of Gaussian excitation, the accuracy of collagen quantication may be aected by the orientation of collagen brils within the excitation volume, and that this eect can be mitigated by using circularly polarized excitation.
For spatially ltering the SHG signal in wave vector space, we used the collecting condenser diaphragm or a blocking mask located just aer the condenser. We note that this spatial ltering should be implemented in Fourier space, so that this conguration for the blocking mask is slightly suboptimal. In practice, we found that an acceptable trade-o between ltering and lateral eld-of-view is typically obtained when blocking the smallest emission angles over two-thirds of the excitation NA.
The SLM used in this study could generate maximal phase shi slightly larger than 2 radians. Larger shis were obtained through phase aliasing between 0 and 2. As described in previous studies32 , the use of a SLM instead of an axicon to produce Bessel beams introduce unwanted spatial replicas and diraction orders. We applied a phase ramp to the SLM hologram and used spatial ltering to select the rst diraction order32. The phase applied by the SLM was therefore of the form:
= +
x y mod rt xt
( , ) (2 2 , 2 ) (3)
x
with t the amplitude of the conical phase and tx the amplitude of the additional linear phase along the x direction.
In terms of light efficiency, the reectivity of the LCoS-SLM used here is 60% (resp. 70%) at 850 nm (resp. 1100nm), and the overall efficiency of our beam shaping system is 23% (resp. 25%) at 850nm (resp. 1100nm).
SCIENTIFIC REPORTS
9
www.nature.com/scientificreports/
To calculate eld distributions at the focus of a high NA objective
E Focus, we used a reformulation of the Debye integral based on Fourier transform (FT), as proposed by Leutenegger et al.33:
x y z FT e
E E
( , , ) ( , )cos (4)
ik z
z
Focus
where
E is the projection on a sphere of the incoming eld E0 in the back aperture of the microscope objective. See also Supplementary gure S3. Thus for a eld linearly polarized along x:
E ( , ) ( , )
1 cos (1 cos )cos(2 ) (cos 1)sin(2 )
2 sin cos
E
=
0
+
cos( )
(5)
The eld in the back aperture plane of the microscope objective is related to the eld in the SLM plane by a Fourier transform. Therefore, if the SLM is illuminated by a Gaussian beam linearly polarized along x, E0 can be written as:
0
E FT e f
( , ) exp sin ( )
(6)
i
( , )
2 2
0
2
where 0 is the waist of the Gaussian beam illuminating the SLM and f the focal length of the projecting lens.
To simulate SHG using Bessel beams, we used a simplied model for Bessel beams that is easier to relate to excitation numerical aperture. Following the approach described in27 for the case of third-harmonic generation, we considered an annular intensity distribution with constant radial phase focused by a high numerical aperture (NA) objective. In this case, the eld in the back aperture reads:
E ( , ) Rect Rect
B B
0
+
+
(7)
where B describes the Bessel beam focusing angle and its angular spread. These parameters are linked to NAB and NAB by the following relations:
=
N A n N A n
sin( )
B 2 cos( ) (8)
B
B B
The excitation eld near focus was discretized on a 201 201251 grid with voxel size of 353570nm3.
The nonlinear polarization induced near focus was calculated as a function of the sample geometry assuming a simplied second-order tensorial response:
P E E
P
P
0
= 0 (9)
x xxx x x
y
z
(2 ) (2) (2 )(2 )
=
=
The harmonic field originating from all positions r in the focal region and propagated to a position
= =
R R X Y Z
( , , ) ( , , ) can then be expressed as3436:
=
E r R r dVR P G
FF ( ) ( ) ( ) (10)
V FF
(2 )
where V spans the excitation volume and GFF is the far eld Greens function:
=
G I RR
exp( )
4 ( / ) (11)
ikR
R R
2
FF
with I the identity matrix.
Emission diagrams were calculated over a sphere of radius R and the projection of the diagrams were displayed on a 2D plane whose axes are given by dimensionless variables =
n X R
/
X and =
n Y R
/
Y .
Finally, the total radiated SHG power was calculated by integrating the far eld intensity on the sphere of radius R with the cone angle of the objective lens:
P = E R dXdY
FF ( ) / cos( ) (12)
2
SHG
Renal brosis was induced in wild-type mice using the AGBM model (anti-glomerular basement membrane glomerulonephritis)37. Mice were sacriced aer 21days, kidney
SCIENTIFIC REPORTS
10
www.nature.com/scientificreports/
were removed and xed and paraffin-embedded unstained coronal kidney sections deposited on glass slides were obtained. The thickness of these histological sections was chosen as 15 m, which is slightly larger than usual histological sections (27m thick), in order to better illustrate depth of eld issues when imaging large regions of sections deposited on slides with poor atness.
All experimental animal protocols were performed in accordance with guidelines of the European Community (L35886/609EEC), and were approved by the Institut National de la Sant et de la Recherche Mdicale and local Ethic Review Board at Paris Descartes University (Paris, France).
KTP (KTiOPO4) nanoparticles were produced as a colloidal suspension following the process previously described in38. The basic principle relies on a coprecipitation of precursors in solution followed by a thermal treatment at 700C of the recovered precipitate. Aer washing the obtained powder to remove excess KCL salt, KTP nanoparticles spontaneously disperse in water owing to a high surface charge from ionized phosphate groups (zeta potential of 45mV in neutral water). Structural characterization show that the particles are highly crystalline, with a size distribution peaking at about 150 nm as determined from dynamic light scattering experiments.
1. Hulmes, D. J. S. Building Collagen Molecules, Fibrils, and Suprabrillar Structures. J. Struct. Biol. 137, 210 (2002).2. Campagnola, P. J. et al. Three-Dimensional High-Resolution Second-Harmonic Generation Imaging of Endogenous Structural Proteins in Biological Tissues. Biophys. J. 82, 493508 (2002).
3. Zipfel, W. R., Williams, R. M. & Webb, W. W. Nonlinear magic: multiphoton microscopy in the biosciences. Nature 21, 13691377 (2003).
4. Brown, E. et al. Dynamic imaging of collagen and its modulation in tumors in vivo using second-harmonic generation. Nat. Med. 9, 796800 (2003).
5. Strupler, M. et al. Second harmonic imaging and scoring of collagen in brotic tissues. Opt. Express 15, 40544065 (2007).6. Tuer, A. E. et al. Hierarchical model of brillar collagen organization for interpreting the second-order susceptibility tensors in biological tissue. Biophys. J. 103, 20932105 (2012).
7. Brown, C. P. et al. Imaging and modeling collagen architecture from the nano to micro scale. Biomed. Opt. Express 5, 233243 (2013).
8. Bancelin, S. et al. Determination of collagen bril size via absolute measurements of second-harmonic generation signals. Nat. Commun. 5, 4920 (2014).
9. Wang, T.-H., Chen, T.-C., Teng, X., Liang, K.-H. & Yeh, C.-T. Automated biphasic morphological assessment of hepatitis B-related liver brosis using second harmonic generation microscopy. Sci. Rep. 5, 12962 (2015).
10. Tai, D. C. S. et al. Fibro-C-Index: comprehensive, morphology-based quantification of liver fibrosis using second harmonic generation and two-photon microscopy. J. Biomed. Opt. 14, 44013 (2009).
11. Pena, A.-M. et al. Three-dimensional investigation and scoring of extracellular matrix remodeling during lung brosis using multiphoton microscopy. Microsc. Res. Tech. 70, 162170 (2007).
12. Gailhouste, L. et al. Fibrillar collagen scoring by second harmonic microscopy: a new tool in the assessment of liver brosis. J. Hepatol. 52, 398406 (2010).13. Thriault, G., De Koninck, Y. & McCarthy, N. Extended depth of eld microscopy for rapid volumetric two-photon imaging. Opt. Express 21, 1009510104 (2013).
14. Thriault, G., Cottet, M., Castonguay, A., McCarthy, N. & De Koninck, Y. Extended two-photon microscopy in live samples with Bessel beams: steadier focus, faster volume scans, and simpler stereoscopic imaging. Front. Cell. Neurosci. 8, 139 (2014).
15. Botcherby, E. J., Jukaitis, R. & Wilson, T. Scanning two photon uorescence microscopy with extended depth of eld. Opt. Commun.
268, 253260 (2006).
16. Heuke, S. et al. Bessel beam CARS of axially structured samples. Sci. Rep. 5, 10991, doi: 10.1038/srep10991 (2015).17. Durnin, J., Miceli, J. J. & Eberly, J. H. Diraction-free beams. Phys. Rev. Lett. 58, 14991501 (1987).18. Durnin, J. Exact solutions for nondiracting beams. I. The scalar theory. J. Opt. Soc. Am. A 4, 651654 (1987).19. Durnin, J., Miceli Jr, J. J. & Eberly, J. H. Comparison of Bessel and Gaussian beams. Opt. Lett. 13, 7980 (1988).20. Friberg, A. T. Stationary-phase analysis of generalized axicons. J. Opt. Soc. Am. A 13, 743750 (1996).21. Jarutis, V., Pakauskas, R. & Stabinis, A. Focusing of LaguerreGaussian beams by axicon. Opt. Commun. 184, 105112 (2000).22. Couture, C.-A. et al. The Impact of Collagen Fibril Polarity on Second Harmonic Generation Microscopy. Biophys. J. 109, 25012510 (2015).23. Strupler, M. et al. Second harmonic microscopy to quantify renal interstitial brosis and arterial remodeling. J. Biomed. Opt. 13, 54041 (2008).
24. Preibisch, S., Saalfeld, S. & Tomancak, P. Globally optimal stitching of tiled 3D microscopic image acquisitions. Bioinformatics 25, 14631465 (2009).
25. Gori, F., Guattari, G. & Padovani, C. Bessel-Gauss beams. Opt. Commun. 64, 491495 (1987).26. Sheppard, C. J. R. & Wilson, T. Gaussian-beam theory of lenses with annular aperture. IEE J. Microw. Opt. Acoust. 2, 105 (1978).27. Olivier, N., Dbarre, D., Mahou, P. & Beaurepaire, E. Third-harmonic generation microscopy with Bessel beams: a numerical study. Opt. Express 20, 2488624902 (2012).
28. Tewari, S. P., Huang, H. & Boyd, R. W. Theory of third-harmonic generation using Bessel beams, and self-phase-matching. Phys. Rev. A 54, 2314 (1996).
29. Wulle, T. & Herminghaus, S. Nonlinear optics of Bessel beams. Phys. Rev. Lett. 70, 14011404 (1993).30. Arlt, J., Dholakia, K., Allen, L. & Padgett, M. J. Efficiency of second-harmonic generation with Bessel beams. Phys. Rev. A 60, 24382441 (1999).
31. Maurer, C., Jesacher, A., Bernet, S. & Ritsch-Marte, M. What spatial light modulators can do for optical microscopy. Laser Photonics Rev. 5, 81101 (2011).
32. Fahrbach, F. O. & Rohrbach, A. A line scanned light-sheet microscope with phase shaped self-reconstructing beams. Opt. Express 18, 2422924244 (2010).
33. Leutenegger, M., Rao, R., Leitgeb, R. A. & Lasser, T. Fast focus eld calculations. Opt. Express 14, 1127711291 (2006).34. Novotny, L. & Hecht, B. Principles of Nano-Optics. (Cambridge University Press, 2006).35. Cheng, J.-X. & Xie, X. S. Greens function formulation for third-harmonic generation microscopy. J. Opt. Soc. Am. B 19, 16041610 (2002).36. Olivier, N. & Beaurepaire, E. Third-harmonic generation microscopy with focus-engineered beams: a numerical study. Opt. Express 16, 1470314715 (2008).
37. Mesnard, L. et al. Genetic background-dependent thrombotic microangiopathy is related to vascular endothelial growth factor receptor 2 signaling during anti-glomerular basement membrane glomerulonephritis in mice. Am. J. Pathol. 184, 24382449 (2014).
38. Mayer, L. et al. Single KTP nanocrystals as second-harmonic generation biolabels in cortical neurons. Nanoscale 5, 84668471 (2013).
SCIENTIFIC REPORTS
11
www.nature.com/scientificreports/
We thank Jean-Marc Sintes and Xavier Solinas for assistance in microscope implementation, and Nicolas Olivier, Chiara Stringari and Ignacio Arganda-Carreras for scientic discussions. This work was supported by Rgion Ile-de-France (DIM Nano-K doctoral fellowship) and by Agence Nationale de la Recherche (contracts ANR-10-INBS-04 France BioImaging and ANR-11-EQPX-0029 Morphoscope2).
N.V., W.S., M.-C.S.-K. and E.B. conceived the experiments. N.V., P.M. and D.D. implemented the optical setup. N.V. performed the experiments and analyzed the data. P.M., N.V. and E.B. performed numerical simulations. T.G. produced KTP nanoparticles. P.-L.T. prepared the histological sections. All authors contributed to the manuscript.
Supplementary information accompanies this paper at http://www.nature.com/srep
Competing nancial interests: Patent FR2984531-B1 describes Bessel beam excitation for SHG microscopy. Patent application FR16/51850 describes spatial ltering for Bessel SHG detection.
How to cite this article: Vuillemin, N. et al. Efficient second-harmonic imaging of collagen in histological slides using Bessel beam excitation. Sci. Rep. 6, 29863; doi: 10.1038/srep29863 (2016).
This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the articles Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/
SCIENTIFIC REPORTS
12
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Copyright Nature Publishing Group Jul 2016
Abstract
Second-harmonic generation (SHG) is the most specific label-free indicator of collagen accumulation in widespread pathologies such as fibrosis, and SHG-based measurements hold important potential for biomedical analyses. However, efficient collagen SHG scoring in histological slides is hampered by the limited depth-of-field of usual nonlinear microscopes relying on focused Gaussian beam excitation. In this work we analyze theoretically and experimentally the use of Bessel beam excitation to address this issue. Focused Bessel beams can provide an axially extended excitation volume for nonlinear microscopy while preserving lateral resolution. We show that shaping the focal volume has consequences on signal level and scattering directionality in the case of coherent signals (such as SHG) which significantly differ from the case of incoherent signals (two-photon excited fluorescence, 2PEF). We demonstrate extended-depth SHG-2PEF imaging of fibrotic mouse kidney histological slides. Finally, we show that Bessel beam excitation combined with spatial filtering of the harmonic light in wave vector space can be used to probe collagen accumulation more efficiently than the usual Gaussian excitation scheme. These results open the way to SHG-based histological diagnoses.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer




