Content area

Abstract

Purpose

Medial opening wedge high tibial osteotomy (MOW HTO) is now a successful operation with a range of indications, requiring an individualised approach to the choice of intended correction. This manuscript introduces the concept of surgical accuracy as the absolute deviation of the achieved correction from the intended correction, where small values represent greater accuracy. Surgical accuracy is compared in a randomised controlled trial (RCT) between gap measurement and computer navigation groups.

Methods

This was a prospective RCT conducted over 3 years of 120 consecutive patients with varus malalignment and medial compartment osteoarthritis, who underwent MOW HTO. All procedures were planned with digital software. Patients were randomly assigned into gap measurement or computer navigation groups. Coronal plane alignment was judged using the mechanical tibiofemoral angle (mTFA), before and after surgery. Absolute (positive) values were calculated for surgical accuracy in each individual case.

Results

There was no significant difference in the mean intended correction between groups. The achieved mTFA revealed a small under-correction in both groups. This was attributed to a failure to account for saw blade thickness (gap measurement) and over-compensation for weight bearing (computer navigation). Surgical accuracy was 1.7° ± 1.2° (gap measurement) compared to 2.1° ± 1.4° (computer navigation) without statistical significance. The difference in tibial slope increases of 2.7° ± 3.9° (gap measurement) and 2.1° ± 3.9° (computer navigation) had statistical significance (P < 0.001) but magnitude (0.6°) without clinical relevance.

Conclusion

Surgical accuracy as described here is a new way to judge achieved alignment following knee osteotomy for individual cases. This work is clinically relevant because coronal surgical accuracy was not superior in either group. Therefore, the increased expense and surgical time associated with navigated MOW HTO is not supported, because meticulously conducted gap measurement yields equivalent surgical accuracy.

Level of evidence

I.

Details

Location
Title
Surgical accuracy in high tibial osteotomy: coronal equivalence of computer navigation and gap measurement
Volume
24
Issue
11
Pages
3410-3417
Publication year
2016
Publication date
Nov 2016
Publisher
John Wiley & Sons, Inc.
Place of publication
Hoboken
Country of publication
United States
Publication subject
ISSN
0942-2056
e-ISSN
1433-7347
Source type
Scholarly Journal
Language of publication
English
Document type
Journal Article
ProQuest document ID
1833024768
Document URL
https://www.proquest.com/scholarly-journals/surgical-accuracy-high-tibial-osteotomy-coronal/docview/1833024768/se-2?accountid=208611
Copyright
European Society of Sports Traumatology, Knee Surgery, Arthroscopy (ESSKA) 2016
Last updated
2023-11-29
Database
ProQuest One Academic