It appears you don't have support to open PDFs in this web browser. To view this file, Open with your PDF reader
Abstract
Background
Low-intensity pulsed ultrasound (LIPUS) has presented good results in the healing of chronic wounds. The objective of this study was to compare the effect of LIPUS on the viability of transverse rectus abdominal muscle (TRAM) flap in different regions (central and epigastric) in rats.
Methods
Twenty-one Wistar male rats were homogeneously distributed into three groups as follows: group 1 (control), animals submitted to surgery only; group 2, animals submitted to surgery and application of LIPUS at the center of the flap; and group 3, animals submitted to surgery and application of LIPUS at the flap area corresponding to the right inferior epigastric artery pedicle. Stimulation was performed immediately after the surgery and within the following 2 days. The percentage of flap necrosis was evaluated by using the ImageJ® software as well as by measuring the temperature variation with infrared thermography (FLIR® T300).
Results
In the percentage calculation of the necrosis area, the application of LIPUS at the center of the flap (group 2) showed significantly smaller difference (26.2 %) compared to group 1 (54.50 %) and group 3 (44.01 %). Analysis of the temperature variation between the groups was performed by using the one-way ANOVA followed by Tukey's test. The results showed that both forms of LIPUS application showed significant differences compared to the control group.
Conclusions
In view of our results, one can conclude that the application of LIPUS at the center of the flap was effective for the viability of TRAM flap in reducing the necrosis area.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer