Coronary artery pressure-drop and distensibility (compliance) are two major, seemingly unrelated, parameters in the cardiovascular clinical setting, which are indicative of coronary arteries patency and atherosclerosis severity. While pressure drop is related to flow, and therefore serves as a functional indicator of a stenosis severity, the arterial distensibility is indicative of the arterial stiffness, and hence the arterial wall composition. In the present study, we hypothesized that local pressure drops are dependent on the arterial distensibility, and hence can provide information on both indices. The clinical significance is that a single measurement of pressure drop could potentially provide both functional and bio-mechanical metrics of lesions, and thus assist in real-time decision making prior to stenting. The goal of the current study was to set the basis for understanding this relationship, and define the accuracy and sensitivity required from the pressure measurement system. The investigation was performed using numerical fluid-structure interaction (FSI) simulations, validated experimentally using our high accuracy differential pressure measurement system. Simplified silicone mock coronary arteries with zero to intermediate size stenoses were used, and various combinations of arterial distensibility, diameter, and flow rate were simulated. Results of hyperemic flow cases were also compared to fractional flow reserve (FFR). The results indicate the potential clinical superiority of a high accuracy pressure drop-based parameter over FFR, by: (i) being more lesion-specific, (ii) the possibility to circumvent the FFR dependency on pharmacologically-induced hyperemia, and, (iii) by providing both functional and biomechanical lesion-specific information.

Details

Business indexing term
Title
Pressure drop and arterial compliance - Two arterial parameters in one measurement
Publication title
Volume
50
Pages
130-137
Publication year
2017
Publication date
2017
Publisher
Elsevier Limited
Place of publication
Kidlington
Country of publication
United Kingdom
ISSN
00219290
e-ISSN
18732380
Source type
Scholarly Journal
Language of publication
English
Document type
Journal Article
ProQuest document ID
1885092549
Document URL
https://www.proquest.com/scholarly-journals/pressure-drop-arterial-compliance-two-parameters/docview/1885092549/se-2?accountid=208611
Copyright
Copyright Elsevier Limited 2017
Last updated
2025-05-01
Database
ProQuest One Academic