Content area

Abstract

Background

Effective treatment of paroxysmal atrial fibrillation (AF) is essential for reducing the risk of stroke and heart failure. Cryoballoon (CB) ablation has been developed as an alternative to the use of radiofrequency (RF) energy for electrical isolation of the pulmonary veins. Herein, we provide long-term data regarding the efficacy of CB ablation in comparison to RF.

Methods

FreezeAF was a randomised non-inferiority study comparing CB ablation with RF ablation for the treatment of patients with drug-refractory paroxysmal AF. Procedural success for the long-term follow-up (30 months) was defined as freedom from AF with an absence of persistent complications.

Results

Of the 315 patients that were randomised and received catheter ablation, 292 (92.7%) completed the 30-month follow-up (147 in the RF group and 145 in the CB group). The baseline characteristics of the RF and CB groups were similar. Single-procedure success was achieved by 40% of patients in the RF group and 42% of the CB group (p < 0.001 for non-inferiority). When including re-do procedures in the analysis, the multiple procedure success rate was 72% in the RF group and 76% in the CB group.

Conclusion

The data provide long-term evidence that CB ablation is non-inferior to RF ablation, with high proportions of patients reporting freedom from AF 30 months after the index procedure.

Details

Title
Cryoballoon vs. open irrigated radiofrequency ablation for paroxysmal atrial fibrillation: long-term FreezeAF outcomes
Author
Luik, Armin; Kunzmann, Kevin; Hormann, Patrick; Schmidt, Kerstin; Radzewitz, Andrea; Bramlage, Peter; Schenk, Thomas; Schymik, Gerhard; Merkel, Matthias; Kieser, Meinhard; Schmitt, Claus
Publication year
2017
Publication date
2017
Publisher
Springer Nature B.V.
e-ISSN
14712261
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
1904763094
Copyright
Copyright BioMed Central 2017