About the Authors:
Victor Koh
Roles Conceptualization, Data curation, Formal analysis, Methodology, Writing – original draft
Affiliations Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Department of Ophthalmology, National University Health System, Singapore
Yih-Chung Tham
Roles Conceptualization, Data curation, Formal analysis, Investigation, Methodology, Project administration, Writing – original draft, Writing – review & editing
Affiliations Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Department of Ophthalmology, National University Health System, Singapore
Carol Y. Cheung
Roles Conceptualization, Formal analysis, Writing – review & editing
Affiliations Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong, China
Baskaran Mani
Roles Conceptualization, Formal analysis, Investigation, Methodology, Writing – review & editing
Affiliations Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Duke-NUS Graduate Medical School Singapore, Singapore
Tien Yin Wong
Roles Conceptualization, Methodology, Project administration, Resources, Writing – review & editing
Affiliations Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Department of Ophthalmology, National University Health System, Singapore, Duke-NUS Graduate Medical School Singapore, Singapore, Yong Loo Lin School of Medicine, National University of Singapore
Tin Aung
Roles Conceptualization, Funding acquisition, Methodology, Project administration, Resources, Writing – review & editing
Affiliations Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Department of Ophthalmology, National University Health System, Singapore, Duke-NUS Graduate Medical School Singapore, Singapore, Yong Loo Lin School of Medicine, National University of Singapore
Ching-Yu Cheng
Roles Conceptualization, Data curation, Formal analysis, Funding acquisition, Investigation, Methodology, Project administration, Resources, Supervision, Validation, Writing – review & editing
* E-mail: [email protected]
Affiliations Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Department of Ophthalmology, National University Health System, Singapore, Duke-NUS Graduate Medical School Singapore, Singapore, Yong Loo Lin School of Medicine, National University of Singapore
ORCID logo http://orcid.org/0000-0003-0655-885X
Introduction
Glaucoma is a major cause of irreversible blindness in the world and is estimated to affect more than 100 million people by the year 2040.[1] If diagnosed early, effective treatment can be implemented to retard visual loss, making glaucoma an important disease to screen. Studies have shown that structural changes of the optic nerve head (ONH) and retinal nerve fiber layer (RNFL) often precede the development of visual field defects.[2, 3] There are now several imaging modalities for the ONH and RNFL including confocal scanning laser ophthalmoscopy (CSLO), scanning laser polarimetry and spectral-domain optical coherence tomography (SD-OCT). These produce highly reproducible, objective and quantitative measurements of the ONH and RNFL.[4, 5]
Previous studies reported that macular ganglion cell layer measurements by SD-OCT have good diagnostic accuracy for detecting glaucoma when combined with visual field testing in the clinic setting.[6, 7] Retinal ganglion cell loss is one of the first layers within the retina to be affected by early glaucoma.[8] As such, the ability to image the macula, which comprises the region with thickest ganglion cell layer could be a promising screening tool for glaucoma in a population-setting. The Cirrus OCT macular cube scan is able to perform auto-segmentation of the retina and isolate just the ganglion cell and inner-plexiform layer (GCIPL) with good reproducibility.[9, 10] This measurement excludes the RNFL layer and as the ganglion cell layer thickness showed less variability compared to RNFL in normal population, hence including the RNFL in the ganglion cell layer analysis may affect the sensitivity in the detection of early glaucoma.[10] It has been shown that GCIPL measurement showed higher diagnostic ability than RNFL thickness in early glaucoma and similar diagnostic ability for moderate and severe glaucoma.[11, 12]
Currently, there is a lack of population-based studies to evaluate the diagnostic performance of macular GCIPL thickness for glaucoma detection in a population setting. Of note, compared to other ethnic groups, the diagnostic performance of glaucoma imaging tools in Asian population has been shown to be significantly lower. The aim of our study was to determine the diagnostic accuracy of macular GCIPL thickness in comparison with ONH and RNFL measures by both OCT and CSLO for glaucoma detection in a population setting.
Materials and methods
This study comprised participants from the Singapore Chinese Eye Study (SCES), a population-based study of Chinese adults in Singapore, aged between 40 and 80 years. The details of SCES had been reported in detail elsewhere.[13] All the participants signed a written informed consent. This study adhered to the Declaration of Helsinki, and ethics committee approval was obtained from the Singapore Eye Research Institute Institutional Review Board.
Study population
Participants were consecutively recruited between Feb 2009 and July 2010. All subjects underwent a full ophthalmic examination including measurement of visual acuity, subjective refraction, intraocular pressure (IOP), gonioscopy, and dilated fundus examination. We excluded those with macular disease, previous vitreo-retinal or refractive surgery and neurological diseases. Glaucoma was defined as having optic nerve features of glaucoma and RNFL defects found on fundus examination and corresponding visual field defects (as described below). This was based on the ISGEO (International Society of Geographical and Epidemiological Ophthalmology) criteria (Category 1 diagnosis for cross sectional prevalence surveys) which included features of glaucomatous optic neuropathy and corresponding visual field. [14]. The control group had intraocular pressure of < 21 mm Hg with open angles, healthy optic discs on clinical examination and normal visual fields (defined as mean deviation and pattern standard deviation within 95% confidence limits, and Glaucoma Hemifield Test within normal limits).
Ocular examination and visual field tests
All patients underwent a standardized and complete ophthalmic examination at the Singapore Eye Research Institute. Subjective refraction and distance best- corrected visual acuity in Log MAR scores were measured by trained optometrists. Both the anterior and posterior segment examination was performed at the slit-lamp (Haag-Streit model BQ-900; Haag-Streit, Switzerland) using a 78 Diopter lens, which included measurements of vertical diameters of the optic disc and cup. All the eyes had the IOP measured using the Goldmann applanation tonometer (Haag-Streit, Switzerland). Keratometry and axial length measurements were obtained from the IOL master. We performed visual field testing using static automated white-on-white threshold perimetry (Swedish interactive threshold algorithm fast 24–2, Humphrey Field Analyzer II; Carl Zeiss Meditec, Inc.). Glaucomatous optic neuropathy had the following characteristic features including localised rim notching or thinning, RNFL defects or disc hemorrhage, and/or disc asymmetry between the 2 eyes. A visual field was defined as reliable if the fixation losses were less than 20%, false-positive rates and false-negative rates were less than 33% each. A visual field would be consistent with glaucoma if the following criteria is met: the presence of three or more significant non-edge contiguous points (p<0.05) and at least one point with p<0.01 in the pattern deviation plot, and Glaucoma Hemifield Test is “outside normal limits”.
Imaging modalities
All the 3 imaging scan types including spectral-domain OCT macular GCIPL scan, Cirrus SD-OCT ONH scan and CLSO scan, were performed in the same visit for each study eye after pupil dilation using tropicamide 1% and phenylephrine hydrochloride 2.5%. Only good quality images were included for analysis.
Spectral-domain OCT (Cirrus SD-OCT, Carl Zeiss Meditec, Inc, Dublin, CA)[15] uses a super luminescent diode laser to achieve 27,000 A-scans per second. The optic disc cube extends over an area of 6 x 6 mm2 covering the optic disc and the peripapillary retina. A built-in algorithm automatically detects the optic disc center and position a calculation circle of diameter 3.46mm (256 A-scans) around the optic disc on the RNFL thickness map.[16] The superior and inferior quadrants are defined as between 45–135 degrees and 225–315 degrees respectively.
Cirrus SD-OCT was also used to acquire macular scan using the macular cube 200 X 200 scan protocol. A detailed description of the Ganglion Cell Analysis (GCA) scanning has been reported elsewhere.[17, 18] In brief, the GCA algorithm (Cirrus SD-OCT software version 6) measured the thickness of macular GCIPL inside a 14.13 mm2 ellipsoid area with the fovea at the center (Fig 1A). The deeper boundary of the RNFL and deeper boundary of the IPL at the macular region were automatically delineated by the GCA algorithm. This isolated segmented layer thus led to measurement of the GCIPL thickness (Fig 1B). The average, minimum and 6 sectoral (supero-temporal, superior, supero-nasal, infero-nasal, inferior, infero-temporal) GCIPL thicknesses were measured from the ellipsoid zone centred on the fovea (Fig 1C). The minimum GCIPL thickness was defined as the lowest GCIPL thickness over a single meridian crossing the annulus. Only good quality images (signal strength equal to or more than 7) were included in the current analysis.
[Figure omitted. See PDF.]
Fig 1.
Cirrus SD-OCT images of the macula of the right eye: (A) colour-coded topographic map, (B) separation of macula into 6 sectors∞ and (C) horizontal scan of the macula showing a segmented GCIPL (measured between the purple and yellow horizontal lines).
https://doi.org/10.1371/journal.pone.0199134.g001
Confocal scanning laser ophthalmoscopy (CSLO) was performed with the Heidelberg Retinal Tomograph 3 (HRT-3; Heidelberg Engineering, Heidelberg Germany) for imaging of ONH and RNFL. The instrument and its principles are described in details elsewhere.[19] HRT-3 cylindrical lenses were adapted for subjects with astigmatism greater than or equal to 1.0 D. Each image was coupled with a standard deviation (SD) to reflect image quality; a SD higher than 40μm was used as exclusion criterion. The optic disc margin was manually drawn by a single trained operator, which was defined as the inner edge of Elschnig’s ring. The HRT-3 software derived optic disc parameters (e.g. neuroretinal rim area, cup area, rim-to-disc area ratio and cup-to-disc area ratio) automatically using a standard reference plane which was defined at 50 μm posterior to the average retinal height between 350° and 356° along the contour line. For this study, the superior quadrant of the retina comprised of the temporal-superior and nasal-superior sectors i.e. +45 to +135 degrees). The inferior quadrant comprised of the temporal-inferior and nasal-inferior sectors i.e. -135 to -45 degrees).
Statistical analysis
Statistical analysis was performed using Stata 12.1 (StataCorp LP, College Station, TX). Eye-specific data was used in this analysis. Independent t-test and chi square test were performed to compare the demographics and ocular characteristics of participants with and without glaucoma. Logit model was first performed where the outcome (glaucoma) was regressed on each above-mentioned imaging parameter, while adjusted for age and gender. Predicted probabilities of these respective logit models (for each imaging parameter) were then estimated to produce receiver operating curves, and in turn, area under receiver operating curves (AUC). The method described by Janes and Pepe was then used for the comparisons of AUCs across different imaging parameters.[20] The sensitivity level of each imaging parameter was also calculated for a fixed specificity level of 85%. Generalized estimating equation models with exchangeable correlation structures were applied to account for the correlation between pairs of eyes for each individual in these analyses. A significance level of P < 0.05 was taken for statistical significance.
Results
Of the original 3,353 study subjects, 1,291 had both HRT and Cirrus SD-OCT scans taken. Among them, 187 had poor HRT scan quality, and another 43 had poor signal strength or motion artefacts in Cirrus SD-OCT scans, thus leaving 1,061 subjects (1,795 eyes) with acceptable quality scans in both HRT and Cirrus SD-OCT included for the final analysis.
Table 1 compared the demographics and ocular characteristics between participants with (n = 60) and without glaucoma (n = 1,001. The participants with glaucoma were significantly older, more likely to be male, had higher IOP and higher cup-disc ratio. For visual field tests of glaucoma participants, the average mean deviation was -8.95 ± 6.85 dB (median = -7.21 dB; range, -30.36 to 4.86 dB) which places the glaucoma severity in the moderate stage.[21]
[Figure omitted. See PDF.]
Table 1. Comparison of demographics and ocular characteristics between non-glaucoma and glaucoma subjects.
https://doi.org/10.1371/journal.pone.0199134.t001
Table 2 compared the diagnostic performance of each measurement from Cirrus macular GCIPL, Cirrus ONH and HRT-3 scans. The best performing measurements for Cirrus macular GCIPL imaging, Cirrus ONH and HRT-3 were minimum GCIPL thickness (AUC = 0.89, 95% CI 0.83 to 0.95), vertical CDR (AUC = 0.94, 95% CI 0.91 to 0.98) and vertical cup-disc ratio (CDR) (AUC = 0.86, 95% CI 0.81 to 0.92) respectively. Post-hoc analysis comparing the best parameter of each imaging tool showed that vertical CDR measured by Cirrus ONH scan performed better than vertical CDR measured by HRT-3 (P = 0.004). However, the difference between vertical CDR measured by Cirrus ONH scan was not significantly different from minimum GCIPL thickness (P = 0.066). In addition, inferior RNFL thickness (AUC = 0.84, 95% CI 0.91 to 0.97) measured using Cirrus OCT showed very similar diagnostic performance as Cirrus OCT’s VCDR and was also better when compared to other parameters measured by HRT-3 and Cirrus SD-OCT macular GCIPL scan (all P≤0.007). Fig 2 compared the AUC of the best diagnostic parameters from all three imaging modalities.
[Figure omitted. See PDF.]
Fig 2. Comparison of area under receiver operating characteristic curve between the best parameters of Heidelberg Retinal Tomography -3 (HRT-3), Cirrus Spectral Domain-optical coherence tomography (SD-OCT) optic nerve head analysis and Cirrus SD-OCT macular ganglion cell-inner plexiform layer (GCIPL) analysis.
https://doi.org/10.1371/journal.pone.0199134.g002
[Figure omitted. See PDF.]
Table 2. Comparison of the area under the receiver-operating curves between the parameters of cirrus SD-OCT macular ganglion cell-inner plexiform layer analysis and optic nerve head analysis, and Heidelberg retinal tomography-3 (HRT-3).
https://doi.org/10.1371/journal.pone.0199134.t002
Table 3 compared the sensitivity of selected parameters from all three imaging modalities at a specificity level of 85%. Macular minimum GCIPL thickness showed sensitivity of 60.53% (95% CI 46.4 to 73.0) but vertical CDR measured using Cirrus OCT ONH scan showed the highest sensitivity (88.64%, 95% CI 75.4 to 96.2) followed by inferior RNFL thickness (81.81%, 95% CI 67.3 to 91.8). Comparing the sensitivity of the best parameters of each imaging tool, vertical CDR measured by Cirrus SD-OCT ONH scan performed better than vertical CDR measured by HRT-3 (65.3%, P = 0.003); and minimum GCIPL thickness (60.5%, p<0.001). Other parameters from HRT-3 and Cirrus SD-OCT generally showed moderate to poor sensitivity in detecting glaucoma at a fixed specificity level of 85%.
[Figure omitted. See PDF.]
Table 3. Comparison of sensitivity values (at 85% specificity) between the parameters of cirrus SD-OCT macular ganglion cell-inner plexiform layer analysis and optic nerve head analysis, and Heidelberg retinal tomography-3 (HRT-3).
https://doi.org/10.1371/journal.pone.0199134.t003
Discussion
Structural imaging tools are an important aspect of diagnostics and monitoring in the glaucoma clinics. However, the diagnostic performances of glaucoma imaging tools are inconsistent in clinic settings and population-based studies, with results more favourable in the former.[22–24] These could be attributed to the differences in glaucoma severity which tend to be more severe and symptomatic in patients attending the glaucoma clinic. There is also a selection bias towards a glaucomatous-looking ONH detected in a clinic which subsequently results in a structural imaging test being more likely to be abnormal. In theory, imaging tools are ideal for screening purpose as they are quick, non-contact, operated by a skilled technician, objective and highly-reproducible. However, there are also limitations which adversely affect the diagnostic accuracy of these imaging tools which include media opacity affecting the image quality,[25] segmentation errors,[26] myopic optic disc[27] and presence of peripapillary atrophy.[28]
For OCT to be used as a glaucoma a screening tool in a population setting, we have to consider the relative low prevalence of glaucoma. In this regard, and it is reasonable for an imaging tool to be judged based on its sensitivity at a higher fixed specificity level of 85%, which was adopted in our study. This provides a generally acceptable balance between a good yield and cost-effectiveness for a screening tool. At a fixed specificity of 85%, the best parameter of Cirrus SD-OCT has a sensitivity of 88.64% (95% CI 75.4, 96.2) which means that only missing one-tenth of glaucoma cases if Cirrus SD-OCT is used for glaucoma screening in population setting. In contrast, at fixed specificity of 85%, inferior or minimum macular GCIPL thickness measurment will miss up to 40% of glaucoma eyes, which seem to suggest that macular GCIPL scan might have limited value for glaucoma screening in an Asian population. Similarly, the best HRT-3 parameter (vertical CDR) will also miss up to 35% of glaucoma eyes in a population screening setting. It is not surprising that vertical CDR measured by Cirrus SD-OCT and HRT-3 differed in their diagnostic performance as the measured vertical CDR has been shown to be poorly correlated.[29] This is primarily due to differences in how the vertical CDR is derived. In HRT-3, retinal surface landmarks, which are not anatomically consistent,[30] are used to identify the disc edges compared to Cirrus SD-OCT which used the termination of Bruch's membrane to delineate the optic disc edge.[31] The latter is considered a more accurate representation of the disc diameter which also forms the basis of a newer ONH parameter, Bruch’s membrane opening–minimum rim width.[32] In addition, in HRT-3, an observer arbitrarily identifies the disc margin which adds to inter- and intra-observer variability compared to Cirrus SD-OCT which automatically delineates the disc margin.
Macular GCIPL thickness measurement is a relatively newer glaucoma detection tool which is postulated to be involved in early glaucoma. Shoji et al. also suggested that GCIPL thickness measurement are less likely to be influenced by changes in axial length or refractive errors which is an advantage in an Asian population with a high prevalence of myopia.[33] Our study is the first to show good diagnostic performance of macular GCIPL thickness measurement for glaucoma screening in an Asian population. Both minimal and inferior GCIPL thickness demonstrated good AUC of above 0.80 which is consistent with previous studies.[34, 35] The inferior macula ganglion cell layer was also postulated to be the earliest and most affected by glaucomatous changes[36] and our findings were consistent with other studies.[34] Although our study showed that macular GCIPL thickness had good diagnostic accuracy for glaucoma, it was still significantly less sensitive than Cirrus SD-OCT ONH and RNFL scan in a population-based setting. This is in contrast to clinic-based case-control studies which reported a better or at least comparable performance between macular GCIPL measurements and peripapillary ONH parameters.[12, 35] Similar to our study, in the population-based Rotterdam study, Springelkamp et al. reported a high AUC of 0.93 but a relatively poorer sensitivity of inferior macular GCIPL thickness which translated into underdiagnosing close to one-third of glaucomatous eyes in a population-based screening (based on abnormal VF loss and ONH changes).Compared to our study, the slight difference in diagnostic performances can be attributed to the differences in population demographics, different OCT machines used and definition of ganglion cell layer thickness. Co-existing macular pathology such as diabetic maculopathy, age-related macular degeneration and myopia[27] may also play a role in influencing the diagnostic performance of GCIPL scans although we have already excluded eyes with these conditions in our study. The role of macular GCIPL imaging for glaucoma could possibly be beneficial when used in combination with RNFL thickness for detection of early glaucoma.[37]
Our study has several strengths which include a standardized ocular examination and glaucoma imaging and a large population-based study comprising all 3 imaging. The definition of glaucoma used in our study was also used in established population studies which include structural (glaucomatous optic neuropathy) and/or functional (abnormal visual fields) criteria.[35, 38] Such definition is better than other studies which defined glaucoma based on visual field tests only, the latter definition could underestimate and unnecessarily reduce the number of eyes classified as glaucoma in a population study by excluding pre-perimetric glaucoma. In addition, as structural ONH changes could precede visual field changes, the latter definition could only include glaucoma which are more advanced in severity which is not an ideal representation of glaucoma severity in a population screening setting. A possible limitation for using structural definition for glaucoma in our study may result in bias which favours imaging tools especially stereometric parameters based on the ONH measurements. However, there are significant differences and poor agreement between clinical assessment of cup-to-disc ratio and structural imaging modalities and even between HRT-3 and SD-OCT measurements.[29, 39] The HRT tend to underestimate vertical CDR by as much as between 0.10 and 0.24[40] and OCT tends to overestimate vertical CDR by as much as between 0.08 and 0.11.[29, 41]
In conclusion, the diagnostic performance of macular GCIPL scan is inferior compared to vertical CDR measured by Cirrus OCT ONH scan in glaucoma screening for an Asian population. SD-OCT ONH scan performed the best in detecting glaucoma with a sensitivity of 88.64% at 85% specificity using vertical CDR of the ONH. Both SD-OCT macular GCIPL and HRT-3 ONH measurements may miss up to 40% of eyes with glaucoma and may not be suitable as screening imaging tools for glaucoma in an Asian population.
Acknowledgments
Ching-Yu Cheng had full access to all of the data in the study and takes responsibility for the integrity of the data and the accuracy of the data analysis.
Citation: Koh V, Tham Y-C, Cheung CY, Mani B, Wong TY, Aung T, et al. (2018) Diagnostic accuracy of macular ganglion cell-inner plexiform layer thickness for glaucoma detection in a population-based study: Comparison with optic nerve head imaging parameters. PLoS ONE 13(6): e0199134. https://doi.org/10.1371/journal.pone.0199134
1. Tham YC, Li X, Wong TY, Quigley HA, Aung T, Cheng CY. Global prevalence of glaucoma and projections of glaucoma burden through 2040: a systematic review and meta-analysis. Ophthalmology. 2014;121(11):2081–90. pmid:24974815
2. Sommer A, Katz J, Quigley HA, Miller NR, Robin AL, Richter RC, et al. Clinically detectable nerve fiber atrophy precedes the onset of glaucomatous field loss. Arch Ophthalmol. 1991;109(1):77–83. pmid:1987954
3. Quigley HA, Katz J, Derick RJ, Gilbert D, Sommer A. An evaluation of optic disc and nerve fiber layer examinations in monitoring progression of early glaucoma damage. Ophthalmology. 1992;99(1):19–28. pmid:1741133
4. Leung CK, Cheung CY, Weinreb RN, Qiu Q, Liu S, Li H, et al. Retinal nerve fiber layer imaging with spectral-domain optical coherence tomography: a variability and diagnostic performance study. Ophthalmology. 2009;116(7):1257–63, 63 e1-2. pmid:19464061
5. Leung CK, Cheung CY, Lin D, Pang CP, Lam DS, Weinreb RN. Longitudinal variability of optic disc and retinal nerve fiber layer measurements. Invest Ophthalmol Vis Sci. 2008;49(11):4886–92. pmid:18539940
6. Medved N, Cvenkel B. Diagnostic accuracy of the Moorfields Regression Analysis using the Heidelberg Retina Tomograph in glaucoma patients with visual field defects. Eur J Ophthalmol. 2007;17(2):216–22. pmid:17415695
7. Leite MT, Zangwill LM, Weinreb RN, Rao HL, Alencar LM, Sample PA, et al. Effect of disease severity on the performance of Cirrus spectral-domain OCT for glaucoma diagnosis. Invest Ophthalmol Vis Sci.51(8):4104–9. pmid:20335619
8. Na JH, Kook MS, Lee Y, Yu SJ, Choi J. Detection of macular and circumpapillary structural loss in normal hemifield areas of glaucomatous eyes with localized visual field defects using spectral-domain optical coherence tomography. Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie. 2012;250(4):595–602.
9. Kajic V, Povazay B, Hermann B, Hofer B, Marshall D, Rosin PL, et al. Robust segmentation of intraretinal layers in the normal human fovea using a novel statistical model based on texture and shape analysis. Optics express. 2010;18(14):14730–44. pmid:20639959
10. Mwanza JC, Oakley JD, Budenz DL, Chang RT, Knight OJ, Feuer WJ. Macular ganglion cell-inner plexiform layer: automated detection and thickness reproducibility with spectral domain-optical coherence tomography in glaucoma. Investigative ophthalmology & visual science. 2011;52(11):8323–9.
11. Nouri-Mahdavi K, Nowroozizadeh S, Nassiri N, Cirineo N, Knipping S, Giaconi J, et al. Macular ganglion cell/inner plexiform layer measurements by spectral domain optical coherence tomography for detection of early glaucoma and comparison to retinal nerve fiber layer measurements. American journal of ophthalmology. 2013;156(6):1297–307 e2. pmid:24075422
12. Mwanza JC, Durbin MK, Budenz DL, Sayyad FE, Chang RT, Neelakantan A, et al. Glaucoma diagnostic accuracy of ganglion cell-inner plexiform layer thickness: comparison with nerve fiber layer and optic nerve head. Ophthalmology. 2012;119(6):1151–8. pmid:22365056
13. Lavanya R, Jeganathan VS, Zheng Y, Raju P, Cheung N, Tai ES, et al. Methodology of the Singapore Indian Chinese Cohort (SICC) eye study: quantifying ethnic variations in the epidemiology of eye diseases in Asians. Ophthalmic epidemiology. 2009;16(6):325–36. pmid:19995197
14. Foster PJ, Buhrmann R, Quigley HA, Johnson GJ. The definition and classification of glaucoma in prevalence surveys. The British journal of ophthalmology. 2002;86(2):238–42. pmid:11815354
15. Knight OJ, Chang RT, Feuer WJ, Budenz DL. Comparison of retinal nerve fiber layer measurements using time domain and spectral domain optical coherent tomography. Ophthalmology. 2009;116(7):1271–7. pmid:19395086
16. Tham YC, Cheng CY, Zheng Y, Aung T, Wong TY, Cheung CY. Relationship between retinal vascular geometry with retinal nerve fiber layer and ganglion cell-inner plexiform layer in nonglaucomatous eyes. Investigative ophthalmology & visual science. 2013;54(12):7309–16.
17. Mwanza JC, Oakley JD, Budenz DL, Chang RT, Knight OJ, Feuer WJ. Macular ganglion cell-inner plexiform layer: automated detection and thickness reproducibility with spectral domain-optical coherence tomography in glaucoma. Invest Ophthalmol Vis Sci.52(11):8323–9. pmid:21917932
18. Koh VT, Tham YC, Cheung CY, Wong WL, Baskaran M, Saw SM, et al. Determinants of ganglion cell-inner plexiform layer thickness measured by high-definition optical coherence tomography. Investigative ophthalmology & visual science. 2012;53(9):5853–9.
19. Weinreb RN. Laser scanning tomography to diagnose and monitor glaucoma. Current opinion in ophthalmology. 1993;4(2):3–6. pmid:10148455
20. Janes H, Pepe MS. Adjusting for covariates in studies of diagnostic, screening, or prognostic markers: an old concept in a new setting. American journal of epidemiology. 2008;168(1):89–97. pmid:18477651
21. Hodapp EPRI, Anderson DR. Clinical Decisions in Glaucoma. St. Louis,Mo: Mosby- Year Book. 1993:52–61.
22. Healey PR, Lee AJ, Aung T, Wong TY, Mitchell P. Diagnostic accuracy of the Heidelberg Retina Tomograph for glaucoma a population-based assessment. Ophthalmology. 2010;117(9):1667–73. pmid:20816247
23. Li G, Fansi AK, Boivin JF, Joseph L, Harasymowycz P. Screening for glaucoma in high-risk populations using optical coherence tomography. Ophthalmology. 2010;117(3):453–61. pmid:20031231
24. Bengtsson B, Andersson S, Heijl A. Performance of time-domain and spectral-domain Optical Coherence Tomography for glaucoma screening. Acta ophthalmologica. 2012;90(4):310–5. pmid:20946342
25. Zheng Y, Cheung CY, Wong TY, Wong W, Loon SC, Aung T. Determinants of image quality of Heidelberg Retina Tomography II and its association with optic disc parameters in a population-based setting. American journal of ophthalmology. 2011;151(4):663–70. pmid:21257147
26. Moreno-Montanes J, Anton A, Olmo N, Bonet E, Alvarez A, Barrio-Barrio J, et al. Misalignments in the retinal nerve fiber layer evaluation using cirrus high-definition optical coherence tomography. Journal of glaucoma. 2011;20(9):559–65. pmid:21336154
27. Aref AA, Sayyad FE, Mwanza JC, Feuer WJ, Budenz DL. Diagnostic specificities of retinal nerve fiber layer, optic nerve head, and macular ganglion cell-inner plexiform layer measurements in myopic eyes. Journal of glaucoma. 2014;23(8):487–93. pmid:23221911
28. Lee KY, Tomidokoro A, Sakata R, Konno S, Mayama C, Saito H, et al. Cross-sectional anatomic configurations of peripapillary atrophy evaluated with spectral domain-optical coherence tomography. Investigative ophthalmology & visual science. 2010;51(2):666–71.
29. Perera SA, Foo LL, Cheung CY, Allen JC, Chua D, Tham YC, et al. Cup-to-Disc Ratio From Heidelberg Retina Tomograph 3 and High-Definition Optical Coherence Tomography Agrees Poorly With Clinical Assessment. Journal of glaucoma. 2015.
30. Strouthidis NG, Yang H, Reynaud JF, Grimm JL, Gardiner SK, Fortune B, et al. Comparison of clinical and spectral domain optical coherence tomography optic disc margin anatomy. Investigative ophthalmology & visual science. 2009;50(10):4709–18.
31. Mwanza JC, Oakley JD, Budenz DL, Anderson DR, Cirrus Optical Coherence Tomography Normative Database Study G. Ability of cirrus HD-OCT optic nerve head parameters to discriminate normal from glaucomatous eyes. Ophthalmology. 2011;118(2):241–8 e1. pmid:20920824
32. Tun TA, Sun CH, Baskaran M, Girard MJ, de Leon JM, Cheng CY, et al. Determinants of optical coherence tomography-derived minimum neuroretinal rim width in a normal Chinese population. Investigative ophthalmology & visual science. 2015;56(5):3337–44.
33. Shoji T, Sato H, Ishida M, Takeuchi M, Chihara E. Assessment of glaucomatous changes in subjects with high myopia using spectral domain optical coherence tomography. Investigative ophthalmology & visual science. 2011;52(2):1098–102.
34. Springelkamp H, Lee K, Wolfs RC, Buitendijk GH, Ramdas WD, Hofman A, et al. Population-based evaluation of retinal nerve fiber layer, retinal ganglion cell layer, and inner plexiform layer as a diagnostic tool for glaucoma. Investigative ophthalmology & visual science. 2014;55(12):8428–38.
35. Jeoung JW, Choi YJ, Park KH, Kim DM. Macular ganglion cell imaging study: glaucoma diagnostic accuracy of spectral-domain optical coherence tomography. Investigative ophthalmology & visual science. 2013;54(7):4422–9.
36. Hood DC, Raza AS, de Moraes CG, Liebmann JM, Ritch R. Glaucomatous damage of the macula. Prog Retin Eye Res. 2013;32:1–21. pmid:22995953
37. Mwanza JC, Budenz DL, Godfrey DG, Neelakantan A, Sayyad FE, Chang RT, et al. Diagnostic performance of optical coherence tomography ganglion cell—inner plexiform layer thickness measurements in early glaucoma. Ophthalmology. 2014;121(4):849–54. pmid:24393348
38. Baskaran M, Ong EL, Li JL, Cheung CY, Chen D, Perera SA, et al. Classification algorithms enhance the discrimination of glaucoma from normal eyes using high-definition optical coherence tomography. Investigative ophthalmology & visual science. 2012;53(4):2314–20.
39. Foo LL, Perera SA, Cheung CY, Allen JC, Zheng Y, Loon SC, et al. Comparison of scanning laser ophthalmoscopy and high-definition optical coherence tomography measurements of optic disc parameters. The British journal of ophthalmology. 2012;96(4):576–80. pmid:22322203
40. Zangwill L, Shakiba S, Caprioli J, Weinreb RN. Agreement between clinicians and a confocal scanning laser ophthalmoscope in estimating cup/disk ratios. American journal of ophthalmology. 1995;119(4):415–21. pmid:7709966
41. Arnalich-Montiel F, Munoz-Negrete FJ, Rebolleda G, Sales-Sanz M, Cabarga C. Cup-to-disc ratio: agreement between slit-lamp indirect ophthalmoscopic estimation and stratus optical coherence tomography measurement. Eye. 2007;21(8):1041–9. pmid:16680099
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
© 2018 Koh et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Abstract
Aims
To determine the diagnostic performance of macular ganglion cell-inner plexiform layer (GCIPL) thickness measured by spectral-domain optical coherence tomography (SD-OCT) for glaucoma detection in a Chinese population in comparison with optic nerve head (ONH) and retinal nerve fiber layer (RNFL) parameters measured by both SD-OCT and Heidelberg Retina Tomography 3 (HRT-3).
Methods
Adults aged 40 to 80 years were recruited from the population-based study (n = 3353, response rate 72.8%). Macular cube 200x200 scan was performed with Cirrus SD-OCT (version 6.0, Carl Zeiss Meditec Inc, Dublin, CA) for GCIPL thickness measurement. ONH and RNFL imaging was performed with Cirrus SD-OCT and HRT-3 (Heidelberg Engineering, Heidelberg, Germany). Glaucoma was defined according to International Society for Geographical and Epidemiological Ophthalmology criteria.
Results
In total, 86 eyes of 60 subjects with glaucoma and 1709 eyes of 1001 non-glaucoma participants were included. The best performing parameters for Cirrus SD-OCT GCIPL, Cirrus SD-OCT ONH and HRT-3 were minimum GCIPL thickness (Area under receiver-operating curve [AUC] = 0.89, 95% CI 0.83–0.95), vertical cup-disc ratio (CDR) (AUC = 0.94, 0.91–0.98) and vertical CDR (AUC = 0.86, 0.81–0.92), respectively. At 85% specificity, vertical CDR measured using Cirrus OCT ONH scan showed the highest sensitivity (88.64%, 95% CI 75.4–96.2) compared to minimum GCIPL thickness with sensitivity of 60.53% (95% CI 46.4–73.0) (p<0.001). Inferior RNFL thickness (AUC = 0.84, 95% CI 0.91–0.97) measured by Cirrus SD-OCT was also superior to Cirrus SD-OCT GCIPL (p<0.007).
Conclusions
The diagnostic performance of macular GCIPL scan is inferior compared to vertical CDR measured by Cirrus OCT ONH scan. Cirrus OCT ONH scan showed the best ability in detecting glaucoma in a Chinese population, suggesting it could be a good glaucoma screening tool in an Asian population.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer