Full Text

Turn on search term navigation

© 2018 Abelairas-Gómez et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Objective

To analyse the acute muscular fatigue (AMF) in triceps brachii and rectus abdominis during compression-only and standard cardiopulmonary resuscitation (CPR) performed by certified basic life support providers.

Methods

Twenty-six subjects were initially recruited and randomly allocated to two study groups according to the muscles analysed; eighteen finally met the inclusion criteria (nine in each group). Both groups carried out two CPR tests (compression-only and standard CPR) of 10 min divided into five 2-min intermittent periods. The ventilation method was freely chosen by each participant (mouth-to-mouth, pocket-mask or bag-valve-mask). CPR feedback was provided all the time. AMF was measured by tensiomyography at baseline and after each 2-min period of the CPR test, in triceps brachii or rectus abdominis according to the study group.

Results

Rectus abdominis’ contraction time increased significantly during the fifth CPR period (p = 0.020). Triceps brachii’s radial muscle belly displacement (p = 0.047) and contraction velocity (p = 0.018) were lower during compression-only CPR than during standard CPR. Participants who had trained previously with feedback devices achieved better CPR quality results in both protocols. Half of participants chose bag-valve-mask to perform ventilations but attained lower significant ventilation quality than the other subjects.

Conclusions

Compression-only CPR induces higher AMF than standard CPR. Significantly higher fatigue levels were found during the fifth CPR test period, regardless of the method. Adequate rescuer’s strength seems to be a requisite to take advantage of CPR quality feedback devices. Training should put more emphasis on the quality of ventilation during CPR.

Details

Title
Acute muscle fatigue and CPR quality assisted by visual feedback devices: A randomized-crossover simulation trial
Author
Abelairas-Gómez, Cristian; ⨯ Ezequiel Rey; ⨯ Violeta González-Salvado; Mecías-Calvo, Marcos; Rodríguez-Ruiz, Emilio; Rodríguez-Núñez, Antonio
First page
e0203576
Section
Research Article
Publication year
2018
Publication date
Sep 2018
Publisher
Public Library of Science
e-ISSN
19326203
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2110049425
Copyright
© 2018 Abelairas-Gómez et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.