This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
1. Introduction
Vibration-based structural health monitoring (SHM) is based on vibration testing of structures which requires high capacity actuators. However, exciting structures in a controlled and repeatable manner is rather limited in practice. In addition, the forced vibration testing is not preferred for heritage building structures where artificial loading might induce significant damage to the tested structures. Thus, monitoring of structural responses from ambient vibration is preferred, since dynamic properties can be identified by analyzing ambient responses of the buildings, for example, heritage court building [1], bell tower of the Monza’s Cathedral [2], three representative monuments in Rome [3] (i.e., the Colosseum, Trajan’s Column, and Aurelian Walls), and the historic Morca suspension footbridge [4]. All of these studies are exclusively for masonry or stony structures.
In Northeast Asia (i.e., Korea, China, Japan, etc.), timber buildings had been traditionally constructed for majestic superstructures on gates of stony castle walls and then have been preserved as heritages so far. These days, portions of the heritage buildings are exposed to rather strong ambient vibration sources. Excitation induced by passage of traffics propagates to the structures. The repeated support excitation might induce functional problems to sensitive equipments or structural damage at the structures. Structural vibration might trigger damage especially for the structures with weathered structural members and weakened structural integrity. In the context, analytical and experimental studies on structural behaviors of historic timber buildings have been conducted: analytical procedure of finite element method was applied to ancient Chinese timber architecture [5]; shaking table and static tests were carried out with scaled models of Japanese temples [6].
Structural vibrations derived from support excitations can be used to characterize the structure [7]. The structural vibratory responses depend on both spectral content of the excitations and dynamic characteristics of the structure. Assuming that the support excitations are random, structural responses represent directly the structural dynamic characteristics which are useful to understand behavior of the structure and further assess structural integrity. For example, natural frequencies and mode shapes can be used for examining overall structural stiffness. The structural stiffness is important especially for the heritage timber structures. At the typical timber framing, all connections between columns and beams are neither rigid nor pinned, since the structural members are fitted with joints secured by wooden pegs. Therefore, estimation of structural stiffness of the timber structures has been considered challenging so far.
The Dongdaemun, designated as the Korean treasure no. 1, is a historic timber structure: it is a two-story wooden building on the platform of stone foundations. It is located at an intersection of busy roads in downtown Seoul being exposed to traffic vibrations. In this study, ambient vibration testing is conducted for the Dongdaemun for the purpose of story stiffness evaluation. The structural responses of ambient vibrations are measured and then analyzed by output-only system identification for estimation of the modal parameters. A simplified rigid body model is adopted to efficiently model the Dongdaemun based on the identified mode shapes. Then, using the identified natural frequencies, an eigenvalue problem of the rigid body model is solved for estimating story stiffnesses of the structure.
2. Ambient Vibration Testing of a Historic Structure
2.1. The Dongdaemun, Korea
Castle walls surrounding Hanyang (the old capital of Korea, now the downtown area of Seoul) were built in Joseon (the final ruling dynasty of Korea, lasted from 1392 to 1910). Among eight gates along the castle walls, the one located at the East is the Dongdaemun, which stands for great gate in the East. The Dongdaemun was originally constructed in 1396, repaired in 1453, and finally rebuilt in 1869. It has two types of distinct structures, as shown in Figure 1(a). The upper structure is a timber frame consisting of beams and supporting columns (i.e., postings), and the lower structure is a massive platform foundation made with stones. The columns and beams of the two-story wooden structure are fitted with joints secured by mortise and tenon without metallic fasteners supporting eaves, bracket complexes and roofs, and so forth.
[figures omitted; refer to PDF]
Three types of columns (Figure 1(b)) support the structure:
[figures omitted; refer to PDF]
2.2. Ambient Vibration Testing
The Dongdaemun is located at an intersection of roads and above two subway lines. Excitation by ambient vibration sources (i.e., passages of vehicles and trains) is conveniently utilized as input to the structure. However, monitoring of structural responses with a high density of sensor array is necessitated due to the unique characteristics of timber frame and complex structural system of the Dongdaemun. To provide a high nodal density using a limited number of sensor nodes, reconfiguration of sensor installation is selected in the ambient vibration testing.
A reconfiguring strategy with up to ten sensor nodes is adopted with the system redeployed six times after the initial deployment with two nodes overlapped. Pairs of accelerometers deployed along longitudinal and lateral directions are installed at each setup. For example, four pairs of sensors are installed at the first Go-Ju (Figure 3(a)) with the elevations of 0.5, 4.0, 5.8, and 8.8 m. Once the installation is complete, monitoring of ambient vibration is conducted. Then, sensors except the nodes 5 and 6 at the first Go-Ju highlighted are reinstalled at another Go-Ju, and two more sensors are installed at the nodes 5 and 6 at the Go-Ju. Similarly, testing and reinstallation are sequentially conducted twice for the remaining Go-Ju’s. After completion of ambient vibration testing at Go-Ju’s, the four pairs of moving sensors are installed twice at four Guigo-Ju’s with the elevations of 5.8, and 8.8 m, respectively for each setup (Figure 3(b)). Finally, ambient vibration testing at Pung-Ju’s is once conducted with sensor installation at the elevation of 8.8 m (Figure 3(c)). It should be noted that sensors at nodes 5 and 6 at the first Go-Ju collected data during the ambient vibration testing at Guigo-Ju’s and Pyung-Ju’s. This reconfiguring strategy realized a dense nodal configuration with 10 sensors installed in 48 nodes at the tested structure.
[figures omitted; refer to PDF]
For measurement of weak ambient vibration in the seven tests, a multichannel high resolution data acquisition system interfaced by accelerometers with high sensitivity is adopted: a National Instruments 16-bit data acquisition system (NI USB-6210) is used with PCB Piezotronics 393B12 integrated circuit piezoelectric (ICP) accelerometers interfaced. The accelerometer measurement range is ±0.5 g, and its spectral noise floor of 100 Hz bandwidth is 0.07 μg/√Hz. The accelerometer is well suited for civil structural monitoring because of its high sensitivity (10 V/g). The data is collected for 480 sec using a 30 Hz sampling frequency.
3. Output-Only Modal Analysis
3.1. Output-Only Modal Analysis Theory Revisited
Output-only modal parameter estimation techniques are categorized into two distinct groups depending on their analysis domains: frequency domain methods dealing with output spectra or power spectral density (PSD) and time domain methods using correlation (i.e., projection in subspace) of past and future outputs. In this study, a frequency domain technique called frequency domain decomposition (FDD) [1] is adopted to estimate the modal parameters of the Dongdaemun. The FDD is basically an output-only version of the conventional complex mode indicator function (CMIF) method [8]. PSD relationship between the system input,
As a counterpart of the frequency domain method of FDD, this study also adopts the stochastic subspace identification (SSI) [8, 9] as a time domain alternative. The output block Hankel matrix is constructed from the measured
The main role of the partitioned output block Hankel matrix is preparing orthogonal projection where the past output works as instrumental variables for elimination of bias estimates due to colored noise output [10]. Two orthogonal projections of the row space of the future output,
Since the projection is equal to the product of the extended observability matrix and the nonstationary Kalman filter state sequence [9], the extended observability matrix and the nonstationary Kalman filter state sequence are calculated respectively as
The one-step shifted state sequence is also calculated as
Modal parameters can be estimated from the estimated system matrices. The estimated system matrix
3.2. Modal Parameter Estimation
The measured acceleration data are analyzed to identify the modal characteristics of the Dongdaemun without known input loading. The quality of the estimated modal parameters by the FDD method is governed by the estimated PSD functions. The PSD function calculated for each sensor location is improved by using a Hanning window on the time-history data prior to the use of the fast Fourier transform (FFT) algorithm. In addition, repeated Fourier spectra calculated from time-history records with 50% overlap between them in the time domain are averaged. This approach to improving the PSD spectra provides a good tradeoff between the reduction of noise and the distinctive qualities of the modal peaks [11].
Figure 4 presents the PSD spectra of the measured longitudinal accelerations at sensor nodes 5, 1, and 1, respectively, for the 1st, 6th, and 7th sensor deployments as representatives of Go-Ju, Guigo-Ju, and Pyung-Ju. A dominant frequency of 1.51 Hz is observed at the three cases. The PSD spectra of the measured lateral accelerations at the sensor nodes 6, 2, and 2, respectively, for the 1st, 6th, and 7th sensor deployments are given in Figure 5. Sharp peaks at 1.13, 1.34, and 4.23 Hz seen at the three cases imply modal frequencies in lateral direction revealing complex vibratory behavior of the structure in the lateral direction.
[figure omitted; refer to PDF] [figure omitted; refer to PDF]Two output-only system identifications are conducted by the frequency-domain FDD and time-domain SSI with the collected ambient vibration data. As for the FDD method, by selecting dominant peaks in the previously calculated PSDs of Figures 4 and 5, natural frequencies are determined, and mode shapes are automatically acquired from the corresponding first singular vector. For the purpose of damping estimation, a variation of half power method, so-called enhanced FDD [12], is adopted using the PSD spectra in lieu of frequency response function. The time-domain SSI is independently conducted with the identical data, and modal parameters are determined. Results of the estimated modal parameters by FDD and SSI are tabulated in Table 1.
Table 1
Identified natural frequencies and damping ratios.
| Modes | Descriptions |
|
|
|
|
|---|---|---|---|---|---|
| 1 | Transversal |
1.13 | 1.11 | 2.35 | 3.07 |
| 2 | Torsional | 1.34 | 1.35 | 2.04 | 3.50 |
| 3 | Transversal |
1.51 | 1.51 | 1.38 | 2.00 |
| 4 | Transversal |
4.23 | 4.20 | 1.56 | 2.32 |
Note: The desciptions of each mode are illustrated in Figure 6.
Table 1 shows natural frequencies and damping ratios in the lateral and longitudinal directions. Overall, the natural frequencies identified by the two methods are very close. However, the damping ratios are a little different, which implies the uncertainty of damping estimation from output-only system identification in the literature [13]. Damping ratios in the lateral direction are larger than those in the longitudinal direction. As a result, flexible and deformable behavior is expected in lateral direction.
The mode shapes calculated for each subsection of the structure are stitched together using the collocated sensors to yield the full global modes of the structure respectively for the two FDD and SSI methods. For quantitative comparison, the modal assurance criterion (MAC) [14] is adopted in this study. The MAC is a scholar index to correlate two sets of mode vectors, defined as
Table 2
MACs for corresponding two sets of mode shapes.
| Modes | 1 | 2 | 3 | 4 |
|---|---|---|---|---|
| MAC | 0.9965 | 0.9855 | 0.9976 | 0.9940 |
[figures omitted; refer to PDF]
4. Model-Based Story Stiffness Estimation
4.1. Simplified Rigid Body Model
Finite element model updating [15, 16] and data-driven structural parameter estimation [17, 18] can be applied to identify structures. However, these approaches are deemed to be rather challenging for its direct application to this study, since the tested structure is a complex timber frame with numerous structural elements. In this regard, a different identification approach of model based data fitting is sought in this study.
The estimated modal characteristics of the Dongdaemun aforementioned in Section 3.2 confirm that identical dominant frequencies are noticed in the PSD spectra regardless of sensor deployments and sensor nodes, which leads to the speculation that the structure behaves as an integrated body. Therefore, a simplified rigid body model with two lumped masses is suggested to idealize the structure under the assumption that sum of flexural rigidities of beam-columns can be replaced equivalently with story stiffness at each mass. In the model, all connections between masses can be considered rotation-free hinges.
As seen in Figure 7, two degrees of freedom are considered for translational motions at each floor.
[figures omitted; refer to PDF]
The equation of motion for the model can be derived using an instant deformed shape of the model with displacements
Assuming rotational angles
Equation (10) can be further symbolized as
4.2. Story Stiffness Estimation
Structural integrity of the Dongdaemun is assessed by story stiffness estimation of the simplified rigid body model: the story stiffnesses are estimated using the vibration model derived as (10) and the modal parameters estimated from the ambient vibration testing. The other parameters in (10) should be known in advance based on geometrical and material properties regarding the structure; referring to the report on field examination of Dongdaemun issued by the authority [20], the parameters are given as
Substituting the given parameters and natural frequencies identified previously into (12), story stiffnesses are uniquely calculated for each vibratory direction of the Dongdaemun. As a result, the story stiffnesses in the lateral direction are calculated as 15.1 and 15.2 kN/mm, respectively, for
5. Conclusions
A Korean heritage property of the Dongdaemun is a historic wooden structure surrounded by lots of traffic such as subway trains, cars, and buses. In this study, a series of ambient vibration tests were conducted to identify the modal parameters of the structure. A dense sensor array was achieved by the virtue of multiple deployments of sensors sharing a small number of fixed reference sensors. Using time-history response data collected from the structure exposed to ambient excitation, offline output-only modal analysis was conducted by frequency domain decomposition and stochastic subspace identification methods. The four modes (i.e., two lateral, one longitudinal, and one torsional modes) were successfully identified. The modal parameters estimated from the two methods were also in a strong agreement.
Based on the experimental findings, a simplified rigid body model was derived for story stiffness estimation. Using the identified natural frequencies and vibration equation described as eigenvalue problem, the story stiffness was calculated. Future work is focused on development of methodology to track structural deterioration for heritage structures based on the proposed story stiffness estimation; schedule-based monitoring of story stiffness of structures investigated gives a means for structural condition assessments along time line.
Acknowledgment
The present research was conducted by the research fund of Dankook University in 2011. The authors gratefully acknowledge the financial support.
[1] R. Brincker, P. Andersen, "Ambient response analysis of the heritage court tower building structure," Proceedings of the 18th International Modal Analysis Conference (IMAC '00), .
[2] C. Gentile, A. Saisi, "Ambient vibration testing of historic masonry towers for structural identification and damage assessment," Construction and Building Materials, vol. 21 no. 6, pp. 1311-1321, DOI: 10.1016/j.conbuildmat.2006.01.007, 2007.
[3] A. Pau, A. De Sortis, R. Marzellotta, F. Vestroni, "Health monitoring of cultural heritage using ambient and forced vibration," Proceedings of the 1st International Conference on Safety and Security Engineering (SAFE '05), .
[4] C. Gentile, N. Gallino, "Ambient vibration testing and structural evaluation of an historic suspension footbridge," Advances in Engineering Software, vol. 39 no. 4, pp. 356-366, DOI: 10.1016/j.advengsoft.2007.01.001, 2008.
[5] W. Xin, M. Zhaobo, "Research on dynamic response of historic timber structure with platform-foundation under metro-induced loads," Proceedings of the 14th International Conference on Computer Supported Cooperative Work in Design (CSCWD '10), pp. 574-578, DOI: 10.1109/CSCWD.2010.5471908, .
[6] Y. Suzuki, M. Maeno, "Structural mechanism of traditional wooden frames by dynamic and static tests," Structural Control and Health Monitoring, vol. 13 no. 1, pp. 508-522, DOI: 10.1002/stc.153, 2006.
[7] J. Kim, J. P. Lynch, "Subspace system identification of support-excited structures-part I: theory and black-box system identification," Earthquake Engineering and Structural Dynamics, vol. 41 no. 15, pp. 2235-2251, DOI: 10.1002/eqe.2184, 2012.
[8] B. Peeters, C. E. Ventura, "Comparative study of modal analysis techniques for bridge dynamic characteristics," Mechanical Systems and Signal Processing, vol. 17 no. 5, pp. 965-988, DOI: 10.1006/mssp.2002.1568, 2003.
[9] P. Van Overschee, B. De Moor, Subspace Identification for Linear Systems, 1996.
[10] M. Verhaegen, V. Verdult, Filtering and System Identification, A least square Approach, 2007.
[11] A. V. Oppenhiem, R. W. Schafer, Discrete-Time Signal Processing, 1999.
[12] R. Brincker, C. E. Ventura, P. Andersen, "Damping estimation by frequency domain decomposition," Proceedings of the 19th International Modal Analysis Conference (IMAC '01), .
[13] J. Kim, J. P. Lynch, "Subspace system identification of support excited structures-part II: gray-box interpretations and damage detection," Earthquake Engineering and Structural Dynamics, vol. 41 no. 15, pp. 2253-2271, DOI: 10.1002/eqe.2185, 2012.
[14] R. J. Allemang, D. L. Brown, "Correlation Coefficient for Modal Vector Analysis," Proceedings of the 1th International Modal Analysis Conference (IMAC '83), .
[15] E. Yu, E. Taciroglu, J. W. Wallace, "Parameter identification of framed structures using an improved finite element model-updating method—part I: formulation and verification," Earthquake Engineering and Structural Dynamics, vol. 36 no. 5, pp. 619-639, DOI: 10.1002/eqe.646, 2007.
[16] Q. W. Zhang, C. C. Chang, T. Y. P. Chang, "Finite element model updating for structures with parametric constraints," Earthquake Engineering and Structural Dynamics, vol. 29, pp. 927-944, 2000.
[17] J. Kim, K. Kim, H. Sohn, "Data-driven physical parameter estimation for lumped mass structures from a single point actuation test," Journal of Sound and Vibration, vol. 132 no. 18, pp. 4390-4402, 2013.
[18] H. Xiao, O. T. Bruhns, H. Waller, A. Meyers, "An input/output-based procedure for fully evaluating and monitoring dynamic properties of structural systems via a subspace identification method," Journal of Sound and Vibration, vol. 246 no. 4, pp. 601-623, DOI: 10.1006/jsvi.2001.3650, 2001.
[19] K. J. Bathe, Finite Element Procedures, 2007.
[20] "The Report on Field Examination of Dongdaemun," , . Jongno-gu Office of Seoul Metroplitan Goverment: Jongno-gu, Seoul, 2006
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Copyright © 2013 Kyung-Won Min et al. This is an open access article distributed under the Creative Commons Attribution License (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License. https://creativecommons.org/licenses/by/4.0/
Abstract
This paper investigates dynamic characteristics of a historic wooden structure by ambient vibration testing, presenting a novel estimation methodology of story stiffness for the purpose of vibration-based structural health monitoring. As for the ambient vibration testing, measured structural responses are analyzed by two output-only system identification methods (i.e., frequency domain decomposition and stochastic subspace identification) to estimate modal parameters. The proposed methodology of story stiffness is estimation based on an eigenvalue problem derived from a vibratory rigid body model. Using the identified natural frequencies, the eigenvalue problem is efficiently solved and uniquely yields story stiffness. It is noteworthy that application of the proposed methodology is not necessarily confined to the wooden structure exampled in the paper.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details
1 Department of Architectural Engineering, Dankook University, Yongin 448-701, Republic of Korea





