Full text

Turn on search term navigation

Copyright © 2019 Milica Isaković et al. This is an open access article distributed under the Creative Commons Attribution License (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License. http://creativecommons.org/licenses/by/4.0/

Abstract

The main drawback of the commercially available myoelectric hand prostheses is the absence of somatosensory feedback. We recently developed a feedback interface for multiple degrees of freedom myoelectric prosthesis that allows proprioceptive and sensory information (i.e., grasping force) to be transmitted to the wearer instantaneously. High information bandwidth is achieved through intelligent control of spatiotemporal distribution of electrical pulses over a custom-designed electrode array. As electrotactile sensations are location-dependent and the developed interface requires that electrical stimuli are perceived to be of the same intensity on all locations, a calibration procedure is of high importance. The aim of this study was to gain more insight into the calibration procedure and optimize this process by leveraging a priori knowledge. For this purpose, we conducted a study with 9 able-bodied subjects performing 10 sessions of the array electrode calibration. Based on the collected data, we optimized and simplified the calibration procedure by adapting the initial (baseline) amplitude values in the calibration algorithm. The results suggest there is an individual pattern of stimulation amplitudes across 16 electrode pads for each subject, which is not affected by the initial amplitudes. Moreover, the number of user actions performed and the time needed for the calibration procedure are significantly reduced by the proposed methodology.

Details

Title
Optimization of Semiautomated Calibration Algorithm of Multichannel Electrotactile Feedback for Myoelectric Hand Prosthesis
Author
Isaković, Milica 1   VIAFID ORCID Logo  ; Malešević, Jovana 2 ; Keller, Thierry 3 ; Kostić, Miloš 4 ; Štrbac, Matija 4 

 University of Belgrade, School of Electrical Engineering, Belgrade, Serbia; Tecnalia Serbia Ltd, Belgrade, Serbia 
 Tecnalia Serbia Ltd, Belgrade, Serbia; University of Belgrade, Belgrade, Serbia 
 Tecnalia Research & Innovation, San Sebastian, Spain 
 Tecnalia Serbia Ltd, Belgrade, Serbia 
Editor
Craig P McGowan
Publication year
2019
Publication date
2019
Publisher
John Wiley & Sons, Inc.
ISSN
11762322
e-ISSN
17542103
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2196471801
Copyright
Copyright © 2019 Milica Isaković et al. This is an open access article distributed under the Creative Commons Attribution License (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License. http://creativecommons.org/licenses/by/4.0/