Abstract
Aim: The aim was to measure doses of eyes and lenses in the presence and absence of shield during whole brain irradiation (WBI). In addition, the dose calculations accuracy of radiation therapy dose plan treatment planning system (TPS) in dose calculation of the eyes and lenses in WBI was evaluated. Materials and Methods: To measure the eyes and lenses doses during WBI, an inhomogeneous phantom of human head was used. Then, the eyes and lenses doses in the presence and absence of shield were measured by EBT3 film. Results: In single fraction with 200 cGy to reference point, average doses received by the left and right eyes in the absence of shield were 20 ± 1.5 and 22 ± 1.0 cGy, respectively, and for the left and right eyes in the presence of shield were 18 ± 2.2 and 21 ± 2 cGy, respectively. In addition, the average dose received by the left and right lenses in the absence of shield were 19.5 ± 0.5 and 18.5 ± 0.5 cGy, respectively, and for the left and right lenses in the presence of shield were 20.5 ± 1.5 and 19.5 ± 1.5 cGy, respectively. The results showed the TPS compared to the film underestimates doses for the eyes and lenses. Conclusion: The average dose received by the eyes and lenses during WBI were estimated around 9–11% of prescribed dose. According to the results, there is probability of radiation-induced cataractogenesis during WBI. By investigating the effect of shield on the lenses and eyes doses, using shield during WBI is not recommended. In addition, the results showed dose calculation accuracy of the TPS for the estimation of doses received by the eyes and lenses during WBI is not acceptable.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details
1 Medical Physics and Medical Engineering Department, Faculty of Medicine; Radiation Oncology Research Center, Cancer Institute, Tehran University of Medical Sciences, Tehran
2 Iran Gamma Knife Center, Tehran
3 Medical Physics and Medical Engineering Department, Faculty of Medicine, Tehran University of Medical Sciences, Tehran