Abstract
Background
The ASTRAL trial showed no difference in clinical outcomes between medical therapy and revascularization for atherosclerotic renal vascular disease (ARVD). Here we report a sub-study using echocardiography to assess differences in cardiac structure and function at 12 months.
Methods
ASTRAL patients from 7 participating centres underwent echocardiography at baseline and 12 months after randomisation. Changes in left ventricular ejection fraction (LVEF), left ventricular mass (LVM), left atrial diameter (LAD), aortic root diameter (AoRD), E:A, and E deceleration time (EDT) were compared between study arms. Analyses were performed using t-tests and multivariate linear regression.
Results
Ninety two patients were included (50 medical versus 42 revascularization). There was no difference between arms in any baseline echocardiographic parameter. Comparisons of longitudinal changes in echocardiographic measurements were: δLVEF medical 0.8 ± 8.7% versus revascularization − 2.8 ± 6.8% (p = 0.05), δLVM − 2.9 ± 33 versus − 1.7 ± 39 g (p = 0.9), δLAD 0.1 ± 0.4 versus 0.01 ± 0.5 cm (p = 0.3), δAoRD 0.002 ± 0.3 versus 0.06 ± 0.3 cm (p = 0.4), δE:A − 0.0005 ± 0.6 versus 0.03 ± 0.7 (p = 0.8), δEDT − 1.1 ± 55.5 versus − 9.0 ± 70.2 ms (p = 0.6). In multivariate models, there were no differences between treatment groups for any parameter at 12 months. Likewise, change in blood pressure did not differ between arms (mean δsystolic blood pressure medical 0 mmHg [range − 56 to + 54], revascularization − 3 mmHg [− 61 to + 59], p = 0.60).
Conclusions
This sub-study did not show any significant differences in cardiac structure and function accompanying renal revascularization in ASTRAL. Limitations include the small sample size, the relative insensitivity of echocardiography, and the fact that a large proportion of ASTRAL patient population had only modest renal artery stenosis as described in the main study.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer