Copyright © 2019 Xiaoming Guan et al. This is an open access article distributed under the Creative Commons Attribution License (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License. http://creativecommons.org/licenses/by/4.0/

Abstract

Damage characteristics and dynamic stress response of aging masonry structures for blast-induced ground motion were performed using high-order local modal analysis method. A complete investigation of damage types and locations of aging masonry buildings due to tunnel blasting vibration were performed by on-site survey. A typical 2-storey aging masonry building located above a tunnel was selected for dynamic response analysis. The experimental dynamic characteristics of the structure were determined by using the operational modal analysis (OMA) method. Finite element models for the masonry structures were updated by modifying material parameters based on OMA results. The first five natural frequencies of the updated finite element models ranged from 8.80–24.99 Hz, and the first five modes were global modes. The sixth to twentieth natural frequencies ranged from 26.10–36.34 Hz, and the sixth to twentieth modes were local modes whose deformation was greater than the global deformation. Since the principal frequencies of the tunnel blast vibration were mostly higher than the natural global modes’ frequencies and were much closer to the natural frequencies of local members, local members experienced more intensive vibrations compared to the main body structure. The principal compressive stress (PCS) and principal tensile stress (PTS) of local members were several times greater than that of the main body structure. Therefore, local members of the masonry building suffered most from the tunnel blasting vibration. Corners due to stress concentration, the contact area between brick and concrete, local members, and precast floor seams are prone to damage during tunnel blasting. With the vibration velocity increasing, the PCS and PTS of local members gradually increase. But, the PTS ratio of local members decreases with the increase of peak particle velocities. The dynamic response analysis result and the damage locations using high-order local modal analysis method are in accordance with the damage found at the site.

Details

Title
Stress Response and Damage Characteristics of Local Members of a Structure due to Tunnel Blasting Vibrations Based on the High-Order Local Modal Analysis
Author
Guan, Xiaoming 1   VIAFID ORCID Logo  ; Zhang, Chunwei 1   VIAFID ORCID Logo  ; Zhao, Fei 1   VIAFID ORCID Logo  ; Mou, Ben 2   VIAFID ORCID Logo  ; Ge, Yiming 1   VIAFID ORCID Logo 

 School of Civil Engineering, Qingdao University of Technology, Qingdao 266033, China 
 School of Civil Engineering, Qingdao University of Technology, Qingdao 266033, China; Cooperative Innovation Center of Engineering Construction and Safety in Shandong Blue Economic Zone, Qingdao University of Technology, Qingdao 266033, China 
Editor
Rafał Burdzik
Publication year
2019
Publication date
2019
Publisher
John Wiley & Sons, Inc.
ISSN
10709622
e-ISSN
18759203
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2253112288
Copyright
Copyright © 2019 Xiaoming Guan et al. This is an open access article distributed under the Creative Commons Attribution License (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License. http://creativecommons.org/licenses/by/4.0/