Full Text

Turn on search term navigation

Copyright © 2019 Michal Voska et al. This is an open access article distributed under the Creative Commons Attribution License (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License. http://creativecommons.org/licenses/by/4.0/

Abstract

Backround. Capsule colonoscopy might present an alternative to colonoscopy for colorectal neoplasia screening. Aim. To assess the accuracy of second-generation capsule colonoscopy (CCE2) for colorectal neoplasia detection compared with conventional colonoscopy (CC). Methods. From 2011–2015, we performed a multicenter, prospective, cross-over study evaluating the use of CCE2 as a possible colorectal cancer (CRC) screening test based on the assessment of the method’s characteristics (accuracy) and safety and patient acceptance of the routine. Enrolled participants fulfilled the CRC screening population criteria if they were asymptomatic, were older than 50, and had no personal or familial history of colorectal neoplasia. The primary outcome was accuracy for the detection of polyps6mm. Secondary outcomes were accuracy for all polyps, polyps10mm, adenomas10mm, and cancers, the quality of bowel cleansing, safety, and CCE2 acceptability by the screening population. Results. A total of 236 individuals were examined; 11 patients (5%) were excluded. Therefore, 225 subjects (95%) were considered in the intention-to-screen (ITS) group. A total of 201 patients (89%) completed both examinations successfully (per protocol group). In the ITS group, polyps were diagnosed during CC in 114 subjects (51%); polyps6mm, polyps10mm, and adenomas10mm were diagnosed in 34 (15%), 16 (7%), and 11 (5%) patients, respectively. The sensitivity of CCE2 for polyps6mm, polyps10mm, and adenomas10mm was 79% (95% confidence interval (CI): 62–91%), 88% (95% CI: 62–98%), and 100% (95% CI: 72–100%), respectively. Conclusion. Second-generation capsule colonoscopy is a safe, noninvasive, and sensitive method for colorectal neoplasia detection although CC remains the preferred method for considerable proportion of subjects. CCE2 may therefore be accepted as the primary screening test for colorectal cancer screening.

Details

Title
Accuracy of Colon Capsule Endoscopy for Colorectal Neoplasia Detection in Individuals Referred for a Screening Colonoscopy
Author
Voska, Michal 1   VIAFID ORCID Logo  ; Zavoral, Miroslav 1 ; Grega, Tomas 1 ; Majek, Ondrej 2 ; Martinek, Jan 3 ; Tacheci, Ilja 4   VIAFID ORCID Logo  ; Benes, Marek 5 ; Vojtechova, Gabriela 1   VIAFID ORCID Logo  ; Drastich, Pavel 5 ; Bures, Jan 4   VIAFID ORCID Logo  ; Spicak, Julius 6 ; Buckova, Barbora 2 ; Ngo, Ondrej 2 ; Suchanek, Stepan 1   VIAFID ORCID Logo 

 Department of Medicine, First Faculty of Medicine, Charles University, Military University Hospital, Prague, CZ 169 02, Czech Republic 
 Institute of Biostatistics and Analyses, Faculty of Medicine, Masaryk University, Brno, CZ 625 00, Czech Republic 
 Department of Medicine, First Faculty of Medicine, Charles University, Military University Hospital, Prague, CZ 169 02, Czech Republic; Department of Hepatogastroenterology, Institute for Clinical and Experimental Medicine, Prague, CZ 140 21, Czech Republic; Charles University in Prague, Institute of Physiology, Czech Republic; University of Ostrava, Medical Faculty, Czech Republic 
 2nd Department of Internal Medicine-Gastroenterology, University Hospital Hradec Kralove, Charles University, Faculty of Medicine in Hradec Kralove, Hradec Kralove, CZ 500 05, Czech Republic 
 Department of Hepatogastroenterology, Institute for Clinical and Experimental Medicine, Prague, CZ 140 21, Czech Republic; GEP Clinic, Prague, CZ 130 00, Czech Republic 
 Department of Hepatogastroenterology, Institute for Clinical and Experimental Medicine, Prague, CZ 140 21, Czech Republic 
Editor
Maria Elena Riccioni
Publication year
2019
Publication date
2019
Publisher
John Wiley & Sons, Inc.
ISSN
16876121
e-ISSN
1687630X
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2290772135
Copyright
Copyright © 2019 Michal Voska et al. This is an open access article distributed under the Creative Commons Attribution License (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License. http://creativecommons.org/licenses/by/4.0/