© 2019 Sagara et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Background

The application of artificial tears before performing perimetry can improve the reliability and results of perimetry in patients with glaucoma and dry eye (DE). However, the effects of ocular surface and tear film conditions on perimetry measurements and reliability have not been fully characterized.

Methods

This prospective, cross-sectional, multicenter study investigated tear metrics in perimetry and assessed the relationships that existed among ocular surface condition, tear condition, and perimetry reliability. Forty-three eyes (43 patients) with DE disease according to the 2016 Japanese diagnostic criteria of DE and 43 eyes (43 subjects) of age- and visual field mean deviation-matched normal control subjects were studied. Perimetry was performed using the Humphrey Field Analyzer (30–2 SITA-Standard). Schirmer’s test, strip meniscometry value, blink rate, tear film break-up time (TFBUT), fluorescein staining of ocular surface, and Dry Eye-related Quality of Life Score (DEQS) were measured. Blink rate was re-measured during perimetry. TFBUT and fluorescein staining were re-evaluated after perimetry. Perimetry reliability was evaluated with fixation loss, false-positive, and false-negative rates.

Results

Blink rate during perimetry was significantly lower for both patients with DE and normal controls (both P<0.001). TFBUT after perimetry was significantly higher than before perimetry in patients with DE (P<0.001). Fluorescein staining of ocular surface was significantly increased in patients with DE and normal control subjects (P = 0.002 and P<0.001, respectively). Spearman correlation analysis revealed that blink rate during perimetry was negatively correlated with fixation-loss rate (r = -0.393, P = 0.009) in patients with DE.

Conclusions

Performing perimetry was associated with a significant change in tear condition and ocular surface condition in both patients with DE and normal control subjects. The changes in tear condition and ocular surface condition may impact the reliability of perimetry in patients with DE.

Details

Title
Impact of tear metrics on the reliability of perimetry in patients with dry eye
Author
Sagara, Hideto; Sekiryu, Tetsuju; Imaizumi, Kimihiro; Shintake, Hiroaki; Sugiyama, Urara; Maehara, Hiroki
First page
e0222467
Section
Research Article
Publication year
2019
Publication date
Sep 2019
Publisher
Public Library of Science
e-ISSN
19326203
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2292048371
Copyright
© 2019 Sagara et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.