© 2019 Liu et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Background

High levels of suspended particulate matters (PMs) and bioaerosols are created by dental procedures. The present study aimed to evaluate the size and concentration of PMs produced by drilling and grinding teeth, and to assess the efficiency of central vacuum system and protective masks for the removal of PMs.

Methods

A total of 20 extracted permanent teeth were collected. A novel experimental system and particle counter were used to evaluate the PMs produced by dental procedures and the PM removal efficiency of a central vacuum system and surgical/N95 masks.

Results

The number concentration of total PMs produced by drilling and grinding teeth was significantly higher than the indoor background concentration. The average aerodynamic diameter of particle was generally less than 1 μm. The average number concentration of ultrafine particles was 2.1x1011 particles/m3 during tooth drilling and grinding. The efficiency of the central vacuum system was 35.74% for PM≥0.5 and 35.41% for PM10. For PM≥0.5, the ratios of inside and outside masks were 0.8–1.34 without vacuum and 1.18–1.36 with vacuum. No difference was found with the use of surgical/N95 masks during dental therapy, with or without vacuum use.

Conclusions

High levels of PMs were found during tooth drilling and grinding procedures, especially among PM1. The PM removal efficiency of a central vacuum system and surgical/N95 masks were limited.

Details

Title
Removal efficiency of central vacuum system and protective masks to suspended particles from dental treatment
Author
Ming-Hui, Liu; Chi-Tsung, Chen; Li-Chuan, Chuang; Wen-Ming, Lin; Gwo-Hwa Wan
First page
e0225644
Section
Research Article
Publication year
2019
Publication date
Nov 2019
Publisher
Public Library of Science
e-ISSN
19326203
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2318697935
Copyright
© 2019 Liu et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.