It appears you don't have support to open PDFs in this web browser. To view this file, Open with your PDF reader
Abstract
The thickness of the sensitive layer has an important influence on the sensitivity of a shear horizontal surface acoustic wave (SH-SAW) biosensor with a delay-line structure and lower layer numbers of graphene produce better sensitivity for biological detection. Therefore, a label-free and highly sensitive SH-SAW biosensor with chemical vapor deposition (CVD-)-grown single-layered graphene (SLG) for endotoxin detection was developed in this study. With this methodology, SH-SAW biosensors were fabricated on a 36° Y-90° X quartz substrate with a base frequency of 246.2 MHz, and an effective detection cell was fabricated using acrylic material. To increase the surface hydrophilicity, chitosan was applied to the surface of the SLG film. Additionally, the aptamer was immobilized on the surface of the SLG film by cross-linking with glutaraldehyde. Finally, the sensitivity was verified by endotoxin detection with a linear detection ranging from 0 to 100 ng/mL, and the detection limit (LOD) was as low as 3.53 ng/mL. In addition, the stability of this type of SH-SAW biosensor from the air phase to the liquid phase proved to be excellent and the specificity was tested and verified by detecting the endotoxin obtained from Escherichia coli (E. coli), the endotoxin obtained from Pseudomonas aeruginosa (P. aeruginosa), and aflatoxin. Therefore, this type of SH-SAW biosensor with a CVD-grown SLG film may offer a promising approach to endotoxin detection, and it may have great potential in clinical applications.
Sensors: High-sensitivity biosensor based on single-layered grapheme film
Researchers in China have invented a biosensor which can detect molecules from bacterial cell walls at just a few nanograms per milliliter. The device is a shear horizontal surface acoustic wave (SH-SAW) biosensor. SH-SAW devices are cheap, sensitive, and can be used label-free, but their performance depends on the characteristics of the sensitive layers. A team led by Xiaojing Mu of Chongqing University used chemical vapor deposition to engineer a device with a single-layered grapheme film as its sensitive layer. They tested its sensitivity in detecting endotoxins, toxic molecules in the cell walls of some bacteria, and found that it could detect quantities as low as 3.53 ng/mL. Further testing showed that the device did not detect glucose or aflatoxin, demonstrating its specificity. Devices based on this design could be useful in clinical settings.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details
1 Chongqing University, Key Laboratory of Optoelectronic Technology & Systems, Ministry of Education, International R & D Center of Micro-nano Systems and New Materials Technology, Chongqing, China (GRID:grid.190737.b) (ISNI:0000 0001 0154 0904)
2 Chongqing University, School of Chemistry and Chemical Engineering, Chongqing, China (GRID:grid.190737.b) (ISNI:0000 0001 0154 0904)
3 Chongqing University, Department of Applied Physics, Chongqing, China (GRID:grid.190737.b) (ISNI:0000 0001 0154 0904)
4 China Electronic Technology Group Corporation, Chongqing Acoustic-Optic-Electric Corporation, Chongqing, China (GRID:grid.190737.b)
5 Chinese Academy of Sciences, Institute of Electronics, Beijing, China (GRID:grid.9227.e) (ISNI:0000000119573309)