Introduction
Atmospheric formaldehyde (HCO) is an intermediate product common to the degradation of many volatile organic compounds (VOCs). While the global formaldehyde background is due to methane oxidation, emissions of non-methane volatile organic compounds (NMVOCs) from biogenic, biomass burning and anthropogenic continental sources result in important and localised production of HCO. The global sink of HCO is due to photolysis and oxidation by OH, resulting in a photochemical lifetime of only a few hours. Elevated concentrations of HCO can therefore be related to the emission of reactive NMVOCs. Monitoring the spatial and temporal variability of NMVOC emissions is essential for a better understanding of the processes that not only control the production and the evolution of tropospheric ozone, a key actor in air quality and climate change, but also of the hydroxyl radical OH and secondary organic aerosols. For these reasons, HCO satellite observations have been increasingly used in combination with tropospheric chemistry transport models to constrain NMVOC emissions (i.a. Palmer et al., 2006; Fu et al., 2007; Millet et al., 2008; Stavrakou et al., 2009a, b; 2014; Curci et al., 2010; Barkley et al., 2013; Fortems-Cheiney et al., 2012; Marais et al., 2012, Zhu et al., 2014).
For more than 15 years, mid-morning formaldehyde tropospheric columns have been retrieved from the successive nadir-scanning spectrometers GOME on ERS-2 (1996–2003) (Chance et al., 2000; Palmer et al., 2001; De Smedt et al., 2008), SCIAMACHY on ENVISAT (2002–2011) (Wittrock et al., 2006; De Smedt et al., 2008) and GOME-2 on MetOp-A and MetOp-B (2006– and 2012–) (De Smedt et al., 2012; Hewson et al., 2013). Since 2004, complementary early afternoon HCO columns have also been available from the OMI imaging spectrometer on Aura (Kurosu, 2008; Millet et al., 2008; González Abad et al., 2015a), and since 2011 from OMPS on SUOMI-NPP (Li et al., 2015; González Abad et al., 2015b). In addition to formaldehyde, glyoxal – another short-lived NMVOC – has also successfully been retrieved from SCIAMACHY (Wittrock et al., 2006), GOME-2 (Vrekoussis et al., 2010; Lerot et al., 2010) and OMI (Alvarado et al., 2014; Chan Miller et al., 2014).
From 2017 onward, the morning observations will be continued with a third GOME-2 instrument to be launched on MetOp-C (Callies et al., 2000), while the afternoon observations will be extended with the TROPOMI instrument (Veefkind et al., 2012), to be launched in 2016 as part of the Copernicus Sentinel 5 Precursor (S-5P) mission, and later with the Sentinel-5 mission to be operated on the MetOp Second Generation platform (Ingmann et al., 2012). Also at the 2020 horizon, the Sentinel-4 instrument on the geostationary Meteosat Third Generation (MTG) platform will allow for hourly observations of HCO over Europe, while TEMPO (NASA) and GEMS (KARI) will provide geostationary measurements for North America and Asia respectively. To realise the full potential of these missions, it is crucial to develop high-quality and consistent retrieval algorithms applicable to the different satellite sensors, taking into account their differences in horizontal resolution and sampling. Likewise, it is essential to understand the diurnal variations of the sources and sinks of formaldehyde, in order to exploit the synergy between the morning and afternoon satellite observations. To our knowledge, so far, the use of combined morning and afternoon HCO satellite observations has only been reported over Amazonia, using SCIAMACHY and OMI measurements (Barkley et al., 2011, 2013).
Ground-based measurements are essential to quantitatively assess the seasonal and diurnal variations of the tropospheric HCO columns. However, up to now, very few validation studies have been reported for satellite HCO observations (Wittrock et al., 2006; Vigouroux et al., 2009) because of the general lack of suitable ground-based measurements, in particular for tropical regions where HCO columns are among the highest worldwide (Stavrakou et al., 2009b; Marais et al., 2012; Barkley et al., 2013). Also, very little attention has been paid to the diurnal variations of the HCO columns and to their local dependencies, which are a complex blend of local NMVOC emission variations, HCO production and loss via oxidation and photolysis depending on local chemical regimes and season. In this regard, the latest generation of MAX-DOAS instruments and retrieval algorithms offer new perspectives for the validation of tropospheric trace gas concentrations and aerosol optical densities (Clémer et al., 2010; Pinardi et al., 2013; Vlemmix et al., 2014; Wang et al., 2014).
This study focuses on tropospheric formaldehyde retrievals from OMI, using an
algorithm historically developed within the TEMIS (Tropospheric Emission
Monitoring Internet Service) framework and applied to morning observations
from the GOME, SCIAMACHY and GOME-2 sensors (
The paper is structured as follows: Sect. 2 introduces the main characteristics of the OMI and GOME-2 instruments. Section 3 describes the new version (v14) of the HCO retrieval algorithm. The HCO tropospheric columns obtained from GOME-2 and OMI measurements are presented and compared in Sect. 4, and the main results of our validation studies are outlined in Sect. 5. Finally, the long-term variations of the HCO columns over the last decade are discussed in Sect. 6.
Satellite instruments
OMI on Aura
The Aura satellite was launched in July 2004, in a Sun-synchronous polar
orbit crossing the Equator around 13:30 LT (in ascending mode). It is the
third major component of the NASA Earth Observing System (EOS) following
Terra (launched 1999) and Aqua (launched 2002). OMI (Ozone Monitoring
Instrument) is a nadir-viewing imaging spectrometer that measures the solar
radiation backscattered by the Earth's atmosphere and surface over the
wavelength range from 270 to 500 nm with a spectral resolution of about
0.5 nm (Levelt et al., 2006). The light entering the telescope is
depolarised using a scrambler and then split into two channels: a UV channel
(wavelength range 270–380 nm) and a VIS (visible) channel (wavelength range
350–500 nm). The 114 viewing angle of the telescope corresponds to
a 2600 km wide swath on the Earth's surface, which enables nearly daily
global coverage. In the nominal global operation mode, the OMI ground pixel
size varies from km at nadir to km at
the edges of the swath. For this work, we have used the OMI Level 1B UV
Global Radiances Data Product (OML1BRUG – version 003) provided on the NASA
website
(
GOME-2 on MetOp-A and MetOp-B
The MetOp-A and MetOp-B satellites were respectively launched in October 2006 and September 2012, in Sun-synchronous polar orbits with Equator-crossing times of 09:30 and 09:00 LT (in descending node). Both satellites carry the same types of GOME-2 (Global Ozone Monitoring Experiment) instruments. Hereinafter, we will refer to them as GOME-2A and GOME-2B (or G2A and G2B). GOME-2 (Callies et al., 2000; Munro et al., 2006) is an improved version of the GOME instrument which flew on the ERS-2 satellite. It is a nadir-viewing scanning spectrometer with four main optical channels, covering the spectral range between 240 and 790 nm with a spectral resolution between 0.26 and 0.51 nm. Additionally, two polarisation components are measured with polarisation measurement devices (PMDs) at 30 broad-band channels covering the full spectral range. A direct Sun spectrum is also measured via a diffuser plate once per day. The default swath width of the GOME-2 scan is 1920 km, allowing for global Earth coverage within 1.5–3 days at the Equator. The nominal ground pixel size is 80 40 km. For this work, we have used the EUMETSAT GOME-2A and GOME-2B level 1B data version 5.3.0 from the beginning of their time series up to mid-June 2014, and version 6.0.0 afterwards.
Formaldehyde retrievals
We use a DOAS (differential optical absorption spectroscopy) algorithm, including three main steps, further detailed in Sects. 3.1, 3.2 and 3.3: (1) the fit of absorption cross-section databases to the log ratio of measured Earth reflectance to retrieve HCO slant columns (, (2) a background normalisation procedure to eliminate remaining unphysical dependencies, and (3) the calculation of tropospheric air mass ( factors using radiative transfer calculations and modelled a priori profiles. The tropospheric HCO vertical column ( is related to intermediate quantities by the equation where is the background-corrected slant column density, and is the model background column in the reference sector. More detailed equations can be found in our previous publications (e.g. De Smedt et al., 2011, 2014).
Level-2 formaldehyde products developed at BIRA-IASB are provided via the
TEMIS website. The algorithms used to generate these products are designed to
be as consistent as possible, in order to optimise the overall coherency of
the resulting time series. Over the years, scientific developments have led
to step-by-step improvements in the quality of the data products. This
entails regular reprocessing of the data sets. The retrieval settings
presented here for the GOME-2 and OMI measurements are based on the BIRA
algorithm developed for GOME-2 (De Smedt et al., 2012), but also include a
number of adaptations allowing for the efficient processing of imaging
instruments and additional improvements as further detailed in this section.
The main differences compared to version 12 are (1) the use of daily
radiances as DOAS reference spectra, (2) the inclusion of O–O in
the BrO and HCO retrieval intervals, and (3) the pre-fit of
O–O in a dedicated retrieval interval. For the reference sector
correction, which so far has been resolved in latitude and time, an
additional dimension (viewing zenith angle or detector row) is now introduced
as a destriping procedure. An updated version of the IMAGES model a priori
profiles is sampled at the respective satellite overpass times. Quality flags
have been defined, in order to better select the valid satellite
observations. Finally, the format of the level-2 data files has been changed
to HDF-5. As for the previous algorithm versions, level-2 and level-3 data
products of version 14 are openly available on TEMIS
(
Slant columns
Typical log ratio of the measured Earth reflectance and fitted low-order polynomial (black and red lines in the first panel), and optical densities of O–O (O, BrO, HCO, O, NO and the Ring effect (solar lines and molecular) in the near UV. The slant columns have been taken as 0. molec cm for O, 10 molec cm for BrO, 10 molec cm for HCO, 10 molec cm for O and molec cm for NO. The different wavelength intervals used in the retrieval are indicated as w1, w2 and w3.
[Figure omitted. See PDF]
The formaldehyde slant columns are retrieved in the interval 328.5–346 nm.
Retrieval settings are summarised in Table 1. We use the QDOAS software
developed at BIRA-IASB for the DOAS retrieval of trace gases from many common
satellite and ground-based instruments. QDOAS is distributed under the GNU
GPL license version 2.0 (Danckaert et al., 2014,
In QDOAS, the wavelength registration of the reference spectrum is fine-tuned
by means of a calibration procedure making use of the solar Fraunhofer lines.
To this end, a highly accurate reference solar atlas (Chance and Kurucz,
2010) is degraded at the resolution of the instrument, through convolution by
the instrumental slit function. The absorption cross sections of the
different trace gases are also convolved with the instrumental slit function.
In the case of GOME-2, the slit function shape is fitted during the
calibration procedure, in order to take into account its changes with time
(Dikty and Richter, 2011; De Smedt et al., 2012). In the case of OMI,
pre-flight measured slit functions (Dobber et al., 2006) are used, and the
calibration is performed for each binned spectrum of the detector array (60
rows). Except for the reported row anomaly that has dynamically evolved over
the years
(
A fifth-order polynomial is used to fit the low-frequency variations of the spectra, as well as a linear offset term. The HCO Meller and Moortgat (2000) laboratory measurements are fitted to the differential absorption features. The absorption cross sections of O at 228 and 243 K, NO and BrO are included. To take into account the Ring effect, two cross sections are used (Vountas et al., 1998). They have been calculated in an ozone-containing atmosphere for low and high SZA (solar zenith angle) using LIDORT RRS (Spurr et al., 2008). Two additional terms (called OL and OO in Table 1), resulting from the Taylor expansion of the O absorption as a function of the wavelength, are included in order to better cope with strong O absorption effects (Puķīte et al; 2010; De Smedt et al., 2012). Introduced in the previous version 12, a second (larger) retrieval interval is used to pre-fit the BrO slant columns (Fig. 1). The benefit of this procedure is to decorrelate the HCO and BrO absorption features, resulting in a reduction of the noise on the BrO and HCO slant columns. However, the O–O (O absorption had not been taken into account in version 12, neither in the larger nor in the shorter interval. While the weak and smooth O signature appears to be well fitted by the fifth-order polynomial used in the shorter interval (Hewson et al., 2013), not including the stronger O term in the larger interval is clearly a shortcoming. Nevertheless, this solution has often been selected in past studies, because experience has shown that including O tends to destabilise the BrO fit (Kurosu, 2008; Begoin et al., 2010; Theys et al., 2011), hence leading to increased noise on the HCO slant columns retrieved in the shorter interval. In version 14, we propose the addition of a third fitting interval (339–364 nm) covering the entire O absorption band around 360 nm (Fig. 1). We use the recently published O absorption cross sections by Thalman and Volkamer (2013), and our HCO retrieval scheme therefore now includes three fitting intervals: w1 for the pre-fit of O, w2 for the pre-fit of BrO, and w3 for the fit of the HCO slant columns, in which the O and BrO slant columns are fixed to values determined in the other intervals.
It should be noted that for the GOME and SCIAMACHY HCO retrievals, only one retrieval interval is used (328.5–346 nm) because the quality of the recorded spectra has been found to be insufficient in the 360 nm region (De Smedt et al., 2008). O absorption effects are therefore significantly reduced.
Summary of retrieval settings used in version 14 of the BIRA HCO retrieval algorithm, applicable to GOME-2 and OMI measurements.
Settings for the DOAS equation parameters | ||
---|---|---|
Calibration | Accurate solar atlas (Chance and Kurucz, 2010) | |
Slit function | OMI: one slit function per binned spectrum as a function of wavelength (Dobber et al., 2006) | GOME-2: asymmetric Gaussian slit function fitted during calibration (De Smedt et al., 2012) |
Reference spectrum | Daily average of radiances selected in the equatorial Pacific | |
Polynomial | Fifth order | |
Intensity offset | Linear offset | |
Hot pixels treatment | Iterative spike removal algorithm (Richter et al., 2011; De Smedt et al., 2014) | |
Absorption cross-section data sets | ||
HCO | Meller and Moortgat (2000) | |
O | Brion et al. (1998), Daumont et al. (1992), Malicet et al. (1995) | |
BrO | Fleischmann et al. (2004) | |
NO | Vandaele et al. (2002) | |
O–O (O | Thalman and Volkamer (2013) | |
Ring effect | Two Ring cross sections calculated in an ozone-containing atmosphere | |
Ring effect | for low and high SZA, using LIDORT RRS (Spurr et al., 2008). | |
Non-linear O absorption effect | Two pseudo cross sections from the Taylor expansion of the wavelength | |
and the O optical depth (Puķīte et al., 2010). | ||
Fitting interval w1: O | 339–364 nm | |
Included cross sections | O (293 K), O (228 K), BrO (223 K), | |
HCO (298 K), NO (220 K), Ring1, Ring2 | ||
Fitting interval w2: BrO | 328.5–359 nm | |
Included cross sections | BrO (223 K), HCO (298 K), O (228 and 243 K), NO (220 K), | |
Included cross sections | O (293 K, not fitted), Ring1, Ring2, OL, OO | |
Fitting interval w3: HCO | 328.5–346 nm | |
Included cross sections | HCO (298 K), O (228 and 243 K), BrO (223 K, not fitted), NO (220 K), | |
Incl | O (293 K, not fitted), Ring1, Ring2, OL, OO |
Figure 2 illustrates the correlation effects occurring between the O, BrO and HCO absorptions, for one OMI orbit on 1 July 2005. The upper panel shows the O differential slant columns retrieved in w1 (339–364 nm, light blue) or in w2 (328.5–359 nm, dark green) as a function of the latitude. The improved quality of the O slant columns in w1 is observed, as expected from Fig. 1. The second and third panels show the differences observed in the BrO and HCO slant columns, depending on whether O is included in the fits or not (v14–v12), as a function of the O slant columns. Those differences are shown for two cases: O slant columns from w1 (light blue, v14) or from w2 (dark green). The pre-fit of O in w1 reduces the noise on the O, BrO and HCO slant columns in the three intervals. The correlation between the three molecules is not reduced by the introduction of this third interval (the slope of the differences remains the same), but the slant columns are limited to more realistic values for each molecule, allowing for an effective reduction of the noise. It is interesting to note that the observed slopes of the differences in BrO and HCO columns are exactly the same for GOME-2 and OMI retrievals and for different periods of the years (not shown), pointing to a fundamental spectral effect rather than an instrumental feature.
Interdependencies between O, BrO and HCO slant columns shown for one OMI orbit of 1 July 2005 (UT 0548). The first panel shows the differential O slant columns retrieved in w1 (339–364 nm, light blue) and in w2 (328.5–359 nm, dark green) as a function of the latitude. The second and third panels show the differences obtained in BrO and HCO slant columns as a function of the O slant columns, when including or not including O in the fits. Differences are shown for two cases: O slant columns retrieved in w1 (light blue) or in w2 (dark green). The limits of the wavelength intervals are indicated in Fig. 1.
[Figure omitted. See PDF]
From Fig. 2, one can conclude that the net effect of including O in the fits is a positive correlation of the HCO slant columns with the O differential columns, with HCO column deviations of less than 10 molec cm but sometimes reaching molec cm for extreme O values. Figure 3 presents O differential slant columns retrieved in w1 from OMI measurements in February and August 2007, giving an idea of the spatial distribution of the expected differences.
Monthly averaged O–O(O differential slant columns retrieved in the interval 339–364 nm. The slant columns are differential since radiance spectra over the equatorial Pacific region (delimited by the black box) are used as reference spectra.
[Figure omitted. See PDF]
Over the Pacific Ocean, the O differential slant columns are generally positive and increase with the solar zenith angle. Figure 4 presents the averaged zonal variation of the HCO, BrO and O differential slant columns for January, April, July and October 2007, as a function of the latitude (a) when O is not included in the fit (v12), and (b) when O is pre-fitted in w1 and included in the fit (v14). Dashed lines show the slant columns before the background normalisation procedure. The decrease of the HCO slant columns with latitude is greatly reduced when O is considered, with a minimum impact on the standard deviations of the columns, owing to the pre-fit of O. However, a positive artificial dependency remains that is related to ozone absorption interferences and still needs to be corrected (see Sect. 3.2). The O effect is exactly the opposite for BrO, for which a decrease of the columns is observed for large O slant columns (about 20 %). This can have a significant impact for BrO studies in polar regions (Salawitch et al., 2010; Choi et al., 2012), but it is beyond the scope of this paper.
Averaged zonal variation of the HCO, BrO and O differential slant columns for 4 months of OMI observations in 2005 (January, April, July, October), over the Pacific Ocean, as a function of the latitude (a) when O is not included in the fit (v12), and (b) when O is included and pre-fitted in w1 (v14). Dashed lines show the slant columns before the background normalisation procedure, while the plain lines show the normalised HCO slant columns.
[Figure omitted. See PDF]
Impact of O on the absolute OMI and GOME-2A HCO columns (respectively in red and green) and on their differences (in black). Dashed lines show results when O is not included in the fits, while solid lines show v14 results.
[Figure omitted. See PDF]
Over the continents, where HCO column enhancements are expected, the differential O slant columns are almost always negative (i.e. lower than over oceans), due to the combined effect of higher altitude and lower surface reflectivity. We observe therefore a decrease of the HCO columns over continental emission regions, by 0 down to 25 %. This reduction is the same for GOME-2 and OMI; that is, it has no impact on the observed diurnal variations. As an example, Fig. 5 presents the time series of GOME-2 and OMI HCO columns over India and equatorial Africa, representative for mid-latitudes and tropical emission regions. Results without (v12) and with (v14) O are plotted, as well as the differences between OMI and GOME-2 for the two versions. A reduction of the columns is observed when including O in the fits, but the OMI-GOME-2 differences are equivalent for v12 and v14.
Across-track and zonal reference sector correction
The use of daily radiance spectra as a reference for the DOAS retrievals results in differential slant columns close to zero in the equatorial Pacific. However, latitude-dependent biases in the HCO columns, due to unresolved spectral interferences, remain a limiting factor for the DOAS retrieval of weak absorbers such as HCO. Furthermore, in the case of a 2-D detector array such as OMI, across-track striping arises, due to imperfect calibration and different dead/hot pixel masks for the detectors. Such instrumental effects also affect scanning spectrometers like GOME-2, but since these instruments have one single detector, these errors do not appear as stripes, but rather as constant offsets (Boersma et al., 2011). These different retrieval artefacts can be compensated for to a certain extent, using normalisation approaches such as the reference sector correction (Kurosu, 2008; De Smedt et al., 2008). As for the DOAS reference radiance selection, the reference sector is chosen in the Pacific Ocean, where the only significant source of HCO is the CH oxidation. The HCO background is replaced by model simulations in the same region. The reference sector correction is also meant to handle possible time-dependent instrumental degradation effects, for example the evolution of the OMI stripe artefacts, or the GOME-2 signal degradation (De Smedt et al., 2012). Note that our analysis shows that the most efficient method to reduce across-track stripes in OMI HCO retrievals is to use row-dependent mean radiances as a reference spectrum in the DOAS equation (see Sect. 3.1).
We apply a two-step normalisation of the HCO slant columns. In a first step, a row-dependent median HCO value is determined in the equatorial Pacific (15 S–15 N, 180–240 E) and subtracted from all the columns (in the case of GOME-2, we use a viewing angle-dependent correction). The aim is to reduce possible remaining offsets between rows, resulting from the different detectors. In addition to the destriping procedure, those OMI rows presenting a level of noise and fitting residuals significantly higher than the average of the other rows for a particular day, are assigned a bad-quality flag and not further used in our applications. This criterion removes a few rows from the analysis in 2005 and, more importantly, all the rows affected by the row anomaly which started in June 2007, and further developed over the years (http://www.knmi.nl/omi/research/product/rowanomaly-background.php). As illustrated by the first line of Fig. 6, the affected rows can be identified using the fitting residuals. This filtering procedure is less systematic than the use of flags provided in the level-1 files, and is aimed to keep as many observations as possible in the analysis, which is of fundamental importance to mitigate the noise on formaldehyde observations. In a second step, the latitudinal dependency of the offset-corrected HCO slant columns is modelled by a polynomial in the entire reference sector (90 S–90 N, 180–240 E). These two corrections are sequentially subtracted from the global slant columns and replaced by the latitudinal dependency of the modelled columns in the same region. The result of the across-track and zonal reference sector correction is illustrated in Fig. 4 as a function of the latitude and in the second line of Fig. 6, showing daily maps of normalised OMI HCO slant columns in 2005 and 2014. The loss of coverage due to the OMI row anomaly and to our filtering scheme is clearly visible when comparing the 2005 and 2014 maps.
Intermediate retrieval quantities of the HCO retrieval algorithm illustrated with OMI on 1 April 2005 (first column) and 1 April 2014 (second column). The first line shows the fit residuals, while lines 2 to 4 show respectively the HCO reference sector corrected slant columns, the air mass factors and the vertical columns.
[Figure omitted. See PDF]
Air mass factors
In the troposphere, scattering by air molecules, clouds and aerosols leads to complex altitude-dependent air mass factors. Multiple scattering calculations are required for the determination of the air mass factors, and the vertical distribution of the absorber has to be assumed a priori. In the case of optically thin absorbers, the formulation of Palmer et al. (2001) is used and has been described for the TEMIS HCO retrievals in De Smedt et al. (2012). It decouples the vertical sensitivity of the measurements (the scattering weighting functions, derived with radiative transfer model calculations) from the vertical profile shape of the species of interest (vertical shape factors, taken from an atmospheric chemistry transport model or from some other prior knowledge of the vertical distribution of the absorber). Details on these two calculation steps are given below. The decoupling of the AMF calculation allows one to address separately the radiative transfer effects, including clouds, and the atmospheric composition of optically thin absorbers like HCO. Vertical columns might be improved for particular locations by using more accurate a priori profiles, for example based on input from regional models, ground-based or aircraft measurements. Furthermore, using shape factors from an atmospheric chemistry model ensures consistency for subsequent evaluation of the model with the retrieved vertical columns (Barkley et al., 2013). For these reasons, the averaging kernels and the a priori profiles are provided in the level-2 data files for each individual measurement. The third line of Fig. 6 presents global daily maps of AMF in April 2005 and 2014. These maps have been filtered for effective cloud fractions larger than 0.4. Clouds and a priori profile shapes are further discussed below and in the validation Sect. 5.2.
Scattering weighting functions
Scattering weighting functions calculated at 340 nm using the LIDORT v3.3 radiative transfer model (Spurr, 2008) are tabulated according to their dependencies with solar, viewing and relative azimuth angles, surface altitude and surface reflectivity. We use the surface reflectivity database derived from OMI by Kleipool et al. (2008), in both GOME-2 and OMI HCO retrievals. Radiative cloud effects are corrected using the independent pixel approximation (IPA, Martin et al., 2002) and the respective cloud products of the instruments provided on the TEMIS website, namely the GOME-2 O A-band Frescov6 product (Wang et al., 2008) and the OMI O cloud product (Stammes et al., 2008). While the cloud fractions are in general good agreement between OMI and GOME-2, we observe larger discrepancies for the cloud altitudes. The differences between OMI and GOME-2 cloud-free AMFs range from 0 to 10 % (observation geometry effects), but the differences between IPA cloud-corrected AMFs can reach 20 % where and when the cloud lies in the lower troposphere. This implies an uncertainty of about 10 % in the final product, since it is not clear whether those cloud-related differences reflect real differences in cloud properties or differences in the cloud retrieval algorithms. This stresses the need for a multi-instrument homogenised cloud product, for example based on the O absorption band that can be measured by all sensors. No explicit correction is applied for aerosols, but the cloud correction scheme accounts for a large part of their scattering effect (Boersma et al., 2011). The uncertainty related to aerosol effects is estimated to be lower than 15 % in average (Leitão et al., 2008; Castellanos et al., 2015; Theys et al., 2015).
Vertical shape factors: IMAGESv2
The a priori profile shapes are extracted from daily simulations performed with the IMAGES model, at 09:30 for GOME-2 and 13:30 for OMI. The IMAGESv2 CTM (chemistry transport model) calculates the global distributions of 90 long-lived and 41 short-lived trace gases at a resolution of 2 (latitude) 2.5 (longitude) and on 40 vertical levels from the surface to the lower stratosphere. The current model version is thoroughly described in Stavrakou et al. (2013). The model time step is set to 4 h. Diurnal changes in the photolysis and kinetic rates, meteorological fields, and the emissions are taken into account through correction factors calculated from a simulation with a 20 min time step (Stavrakou et al., 2009a) and applied to model runs using longer time steps. Simulations have been performed for all years between 2005 and 2013, spun up by a period of 4 months.
Anthropogenic VOC emissions are obtained from the RETRO 2000 global database (Schultz et al., 2008) and are kept constant throughout the years. Over Asia, RETRO is overwritten by the REASv2 inventory (Kurokawa et al., 2013) until 2008, whereas 2008 values are used for more recent years. Anthropogenic VOC emissions are equal to 147 and 150 Tg VOC in 2005 and 2006, respectively, and to 156 Tg VOC for the following years. Emissions of isoprene from vegetation are taken from the MEGAN-MOHYCAN-v2 inventory (Stavrakou et al., 2014). The global annual fluxes range between 323 and 363 Tg isoprene, the lowest and the highest values corresponding to 2008 and to 2010, respectively. Open biomass burning emissions are taken from the GFEDv3 inventory (van der Werf et al., 2010) until 2011, whereas a climatological mean based on 1997–2011 GFEDv3 emissions is used for 2012 and 2013. Global annual fire emissions range between 70 Tg VOC (in 2009) and 105 Tg VOC (in 2010).
The photochemical production of HCO is estimated at ca. 1600 Tg annually. The main formaldehyde sinks are the oxidation by OH (Sander et al., 2011) which leads to CO production and conversion of OH to HO, and two photolysis reactions which produce CO and HO radicals. Based on IMAGESv2 model calculations, photolysis is by far the dominant removal process, estimated at 71 % of the global sink, whereas the OH sink is less efficient (26 %). Dry and wet deposition account for the remainder ( 3 %). The global photochemical HCO lifetime is estimated at 4.5 h.
Quality criteria of the HCO vertical columns
The HCO level-2 files of version 14 are provided in HDF-5 format. They include all the intermediate quantities of the HCO retrieval from slant columns to vertical columns, air mass factors (cloud free or including the IPA cloud correction) and averaging kernels. A detailed error budget is also provided. Error contributions resulting from each step of the retrieval to the final vertical column error are provided separately, including their random and systematic parts (for details, see De Smedt et al., 2014). This allows for an estimation of the total error on the column averages. A quality flag is also provided for each observation. The following criteria are considered for assigning a bad-quality ( 0) flag:
-
per orbit: fit residuals larger than 3 times the averaged fit residual
-
per day: unsuccessful across-track and zonal reference sector correction (see Sect. 3.2)
-
per orbit: corrected slant columns lower than the mean corrected column minus 3 times the column standard deviations
-
per pixel: effective cloud fractions larger than 0.4
-
per pixel: snow or ice flag in the cloud product
-
per pixel: solar zenith angles larger than 70
-
per pixel: individual vertical column errors larger than 3 times the column
GOME-2 and OMI HCO vertical columns
Background values and precision
Time series of HCO retrieval statistics for OMI and GOME-2 on METOP-A and MetOp-B in the remote equatorial Pacific region ([15, 15] lat., [180, 240] long.). The first panel presents the HCO vertical columns, before and after background correction (dotted and plain lines). The second, third and fourth panels present respectively the fit residuals, the column standard deviation and the number of valid observations. See text for details on the DOAS retrieval settings.
[Figure omitted. See PDF]
Figure 7 presents time series of monthly averaged GOME-2A, GOME-2B and OMI HCO vertical columns in the reference sector (first panel) together with the retrieval residuals, standard deviations and number of observations (second to fourth panels). In the first panel, uncorrected columns are displayed with dotted lines, while background-corrected columns are represented with plain lines. From this figure, it can be concluded that even the uncorrected OMI HCO columns are remarkably stable in time (yet across-track and zonal corrections are needed). In the case of GOME-2A retrievals, however, the use of radiances as DOAS reference spectra does not completely compensate for a weakening of the signal over the years, although the loss of signal is reduced by a factor of 2 compared to the use of solar irradiances, as was the case in version 12 (De Smedt et al., 2012).
Regarding the fit residuals and the standard deviations of the monthly averaged HCO columns, the OMI retrievals also show a very good stability in time, the random errors having increased by less than 4 % in 10 years, while the GOME-2A random errors have increased at a rate of about 10 % per year due to degradation effects. Accordingly, the OMI HCO individual pixel precision is about molec cm, while the GOME-2A precision degraded from to molec cm. The GOME-2B performances are found to be equivalent to those of GOME-2A in its early lifetime; however, a degradation rate similar to the one of GOME-2A is expected.
As shown in the fourth panel, the number of OMI observations passing our quality criteria has decreased by 40 % since the beginning of the mission due to the row anomaly issue. The resulting change of sampling has an impact on the calculated monthly means that should be taken into account in trend analyses (see Sect. 6).
Continental emission regions
HCO vertical columns retrieved from GOME-2/MetOp-A (first panel, EUMETSAT level-1 data), OMI/Aura (second panel, NASA level-1 data), and their absolute differences (third panel) between 2007 and 2013.
[Figure omitted. See PDF]
HCO vertical columns retrieved from GOME-2/MetOp-A (first row) and OMI/Aura (second row) over Europe (from April to September) and Asia (from February to November), between 2007 and 2013. Note that different colour scales have been used for GOME-2 and OMI.
[Figure omitted. See PDF]
Figure 8 presents multi-year maps of HCO vertical columns retrieved from GOME-2A and OMI between 2007 and 2013, and their averaged absolute differences over the same period. For these maps (and further below), the quality flags as defined in Sect. 3.4 have been used to filter out invalid satellite observations. We observe consistent HCO distributions, with the highest columns over tropical regions, India, China, south-eastern China and the south-eastern US. We also observe noticeable differences, OMI showing more elevated columns at mid-latitudes and over regions with moderate HCO concentrations, but lower columns in the tropics, where the HCO columns are highest. To better visualise the regional structures, Fig. 9 presents HCO vertical columns derived from both sensors over Europe (from April to September) and Asia (from March to November), averaged between 2007 and 2013.
Mean seasonal and diurnal variations of the HCO columns as observed by MAX-DOAS or FTIR instruments (in black) and by GOME-2 and OMI (in red). Values are shown for five regions where BIRA-IASB operates ground-based measurements: Cabauw and Brussels (northern Europe), OHP (southern France), Beijing and Xianghe (north-eastern China), Bujumbura (central Africa) and Reunion (southern Africa). Satellite measurements have been averaged within 100 km around each location, and filtered using quality criteria as defined in Sect. 3.4. Details of the ground-based measurements are summarised in Table 3.
[Figure omitted. See PDF]
Different effects can be identified.
-
The better horizontal resolution of OMI allows for a better identification of strong hotspots over localised HCO sources, as for example over cities like Mexico City, Pretoria, Hong Kong/Guangdong, Beijing, Cairo, Tehran and Mumbai. This resolution effect can also be identified along coastal areas (Cape Town (South Africa), the Algerian coast, the Turkish coasts, Kerala (India) or California (US)) and along mountain chains (north of India, Pyrenees, Alps).
-
The increase in HCO columns between 09:30 and 13:30 appears to be largest over southern Europe, southern Australia, north-eastern China or central Siberia, while an inverse diurnal variation, of equivalent magnitude, is observed over the equatorial forests of the Amazon, Africa and Indonesia. The same effect has been reported for glyoxal columns, another important indicator of NMVOC emissions (Alvarado et al., 2014). The observed diurnal variations will be further discussed in Sect. 5, using ground-based observations.
-
Differences in retrieval sensitivity appear when comparing GOME-2 and OMI. We note that over oceans, poleward of 30, OMI columns are found to be higher than GOME-2. These differences cannot be explained only by the diurnal variation of the CH oxidation, but they also result from a relative lack of sensitivity of GOME-2 to lower tropospheric HCO in comparison to OMI. This is due to the morning overpass time of GOME-2, which leads to larger SZA over middle and high latitudes (and therefore to lower sensitivity to the lowest atmospheric layers) and to lower HCO concentrations (and therefore to lower absorption).
Table 2 provides a list of regions where the highest annual HCO columns are observed. The annual means are provided with the standard deviations of the monthly averaged columns, as an indication of the amplitude of the seasonal variations. The same regions stand out in both the GOME-2 and OMI observations, with equivalent seasonal variations. However, as shown on the maps, the GOME-2 observations are maximal in the tropics (Africa and South America), while the OMI observations maximise over megacities like Hong Kong/Guandong or Delhi. As can be deduced from the seasonal deviations provided in Table 2, the largest seasonal variations are found in Rondônia (Brazil) and Tianjin (China), for both instruments. Interestingly, the OMI HCO columns exhibit large seasonal variations along the coasts of India, which are less pronounced in GOME-2 observations (Goa, Kerala, Orissa). This could be explained by resolution effects or by diurnal variations in the HCO production and loss processes during the monsoon season. In Sect. 6, the complete time series of monthly averaged HCO vertical columns in China, India, Africa, South America, North America and Europe are presented.
GOME-2A and OMI largest annual mean HCO columns between 2007 and 2013 (10 molec cm.
Continent | Country | Province/state | GOME-2A | seas.dev. | OMI | seas.dev. |
---|---|---|---|---|---|---|
Africa | Congo | 9.37 | 1.71 | 7.74 | 1.27 | |
Africa | Ghana | 8.97 | 2.79 | 8.47 | 2.6 | |
Africa | Sierra Leone | 10.26 | 3.76 | 9.21 | 3.95 | |
Africa | Togo | 8.96 | 2.77 | 8.49 | 2.62 | |
Asia | Bangladesh | 9.76 | 1.48 | 10.5 | 2.3 | |
Asia | Cambodia | 8.63 | 3.39 | 8.74 | 3.71 | |
Asia | China | Anhui | 7.96 | 2.85 | 9.21 | 3.18 |
Asia | China | Guangdong | 8.59 | 1.44 | 9.82 | 1.34 |
Asia | China | Guangxi | 8.6 | 1.88 | 9.04 | 1.63 |
Asia | China | Hong Kong | 9.05 | 2.25 | 11.86 | 3.53 |
Asia | China | Jiangsu | 7.81 | 3.24 | 9.39 | 3.64 |
Asia | China | Tianjin | 7.8 | 4.75 | 9.86 | 3.84 |
Asia | India | Bihar | 9.67 | 1.44 | 10.5 | 2.01 |
Asia | India | Dadra and Nagar Haveli | 7.93 | 2.32 | 9.5 | 3.92 |
Asia | India | Daman and Diu | 8.35 | 2.5 | 9.27 | 4.31 |
Asia | India | Delhi | 10.2 | 2.85 | 12.2 | 2.91 |
Asia | India | Goa | 7.73 | 3.08 | 9.41 | 4.61 |
Asia | India | Haryana | 9.24 | 2 | 10.95 | 2.16 |
Asia | India | Kerala | 7.26 | 2.76 | 9.34 | 4.10 |
Asia | India | Orissa | 9.06 | 2.38 | 9.92 | 3.01 |
Asia | India | Punjab | 9.09 | 1.97 | 10.97 | 2.26 |
Asia | India | Tripura | 8.76 | 1.68 | 9.79 | 2.47 |
Asia | India | Uttar Pradesh | 8.79 | 1.58 | 10.2 | 1.69 |
Asia | India | West Bengal | 9.85 | 1.61 | 10.79 | 2.34 |
Asia | Singapore | 9.14 | 2.79 | 8.9 | 3.62 | |
Asia | Thailand | 8.5 | 3.17 | 8.79 | 3.58 | |
South America | Brazil | Mato Grosso | 11.19 | 4.23 | 8.72 | 3.82 |
South America | Brazil | Rondônia | 11.04 | 5.29 | 8.8 | 4.71 |
South America | Brazil | Tocantins | 10.55 | 2.66 | 8.62 | 2.57 |
South America | Bolivia | 8.91 | 2.96 | 6.19 | 2.46 |
Validation using MAX-DOAS measurements
We validate the observed satellite column variations using ground-based measurements operated by BIRA-IASB at seven stations: Cabauw, Brussels, the Haute-Provence Observatory, Beijing, Xianghe, Bujumbura and Reunion. Details of the ground-based measurements, and related publications, are summarised in Table 3. In Reunion, measurements have been performed with an FTIR instrument (Vigouroux et al., 2009), while at all other stations, multi-axis DOAS (MAX-DOAS) instruments have been used. Although installed at the end of 2013, the Bujumbura instrument could only deliver 6 months of data due to a failure of the UV channel in April 2014.
The MAX-DOAS measurement technique has been developed to retrieve tropospheric trace gas total columns and profiles. The most recent generation of MAX-DOAS instruments allows for measurement of aerosols and a number of tropospheric pollutants, such as NO, HCO, SO, HONO, O and CHOCHO (see e.g. Heckel et al., 2005; Clémer et al., 2010; Irie et al., 2011; Ma et al., 2013; Hendrick et al., 2014; Vlemmix et al., 2014; Wang et al., 2014). HCO slant columns have been retrieved from the six MAX-DOAS instruments using consolidated settings published in Pinardi et al. (2013). While the scientific-grade instruments installed in China and in Bujumbura allow for vertical profile retrievals by optimal estimation (Clémer et al., 2010; Hendrick et al., 2014), only vertical columns could be retrieved from the less sensitive instruments operated at the other stations. We therefore use the ground-based total columns to validate the seasonal and diurnal variations in all stations, while a more quantitative validation making use of the profile information is performed in Beijing/Xianghe and Bujumbura.
Seasonal and diurnal variations
Figure 10 presents the mean diurnal variations of the HCO columns, averaged by season over the complete period of measurements, as observed from the ground (in black) and from space (in red). For this figure, measurements in Cabauw and Brussels have been combined, as well as those in Beijing and Xianghe. We therefore consider five validation sites, representative for different emission sources and illumination conditions. The satellite observations are averaged within 100 km around each station, and filtered as described in Sect. 3.4. Although larger than the typical length of air masses sampled by a MAX-DOAS spectrometer, which is less than a few tens of kilometres (Gomez et al., 2014), this radius allows inclusion of enough satellite pixels to ensure significant analysis. MAX-DOAS observations are filtered using similar thresholds on total errors (retrieval errors larger than 3 times the columns) and solar zenith angles (70). Cloudy observations are excluded using the multiple-scattering cloud filter described in Gielen et al. (2014) since such sky conditions can potentially degrade the quality of the MAX-DOAS retrievals. The error bars shown in Fig. 10 include random and systematic error contributions. The random errors are taken as the standard deviations of the daily averaged observations divided by the square root of the number of days considered in the seasonal means. Wintertime satellite columns in Europe and China are not shown, because of their reduced quality resulting from a combination of low HCO values and lower satellite sensitivity close to the surface. Furthermore, Table 4 provides quantitative differences between the afternoon and morning observations for the five locations, in each season. Both for satellite and ground-based measurements, the correlations between 09:30 and 13:30 columns have been considered to estimate the error in the differences, using a standard uncertainty propagation formulation.
The first conclusion that can be drawn from Fig. 10 is the general underestimation of the satellite columns by 0 up to 50 % compared to the MAX-DOAS observations, especially during the seasons of maximum concentration. In comparison, the agreement is found to be better with tropical background FTIR measurements (Vigouroux et al., 2009). The second conclusion is the qualitative agreement between the satellite and ground-based measurements regarding the HCO column variations. The seasonal variations are in very good agreement, with a maximum in summertime in mid-latitude regions, especially in the south of France and in China. Regarding diurnal variations, the differences between the OMI and GOME-2 columns should reflect the change in HCO between 09:30 and 13:30. However, uncertainties in the satellite HCO columns are large (De Smedt et al., 2012), and so are the errors in their differences, as reflected in Table 4. Nevertheless, the sign of the differences between GOME-2 and OMI agrees well with both MAX-DOAS and FTIR measurements. Early afternoon values are almost always equal to or larger than mid-morning values, except in Bujumbura, where morning columns are larger. The amplitude of the diurnal variation inferred from ground-based and satellite data is also in relatively good agreement, as can be seen by comparing the slopes between 09:30 and 13:30, and from Table 4. This is less true for summertime columns in Brussels/Cabauw, or for springtime columns in OHP and in Beijing/Xianghe, where the differences in OMI-GOME-2 are larger than the corresponding MAX-DOAS variations, possibly pointing to an underestimation of the GOME-2 retrievals in those regions/periods.
Summary of ground-based measurements available at BIRA-IASB.
Station/country (lat, long) | Instrument | Period | Retrieved quantity | Reference |
---|---|---|---|---|
Cabauw/the Netherlands (52 N, 5 E) | MAX-DOAS | 18 June 2009–21 July 2009 | VCD | Pinardi et al. (2013) |
Brussels/Belgium (50.78 N, 4.35 E) | Mini-MAX-DOAS | 1 May 2011–23 April 2012 | VCD | Gielen et al. (2014) |
OHP/France (43.94 N, 5.71 E) | MAX-DOAS | 26 July 2007–20 March 2013 | VCD | Valks et al. (2011) |
Beijing/China (39.98 N, 116.38 E) | MAX-DOAS | 3 July 2008–17 April 2009 | VCD profile | Vlemmix et al. (2014) |
Xianghe/China (39.75 N, 116.96 E) | MAX-DOAS | 7 March 2010–26 December 2013 | VCD profile | Vlemmix et al. (2014) |
Bujumbura/Burundi (3 S, 29 E) | MAX-DOAS | 25 November 2013–22 April 2014 | VCD profile | – |
Reunion/France (20.9 S, 55.5 E) | FTIR | 1 August 2004–25 October 2004 21 May 2007–15 October 2007 2 June 2009–28 December 2009 11 January 2010–16 December 2010 | VCD | Vigouroux et al. (2009) |
Mean diurnal variations of the HCO columns as observed with ground-based and satellite instruments. Values are given for five regions where BIRA-IASB operates ground-based measurements: Cabauw and Brussels, OHP, Beijing and Xianghe, and Bujumbura and Reunion. Details of the ground-based measurements are summarised in Table 3.
Station | Instrument | Absolute 13:30–09:30 difference (10 molec cm | |||
---|---|---|---|---|---|
DJF | MAM | JJA | SON | ||
Cabauw, Brussels | OMI-GOME-2 | – | 14 24 | 25 27 | 21 37 |
MAX-DOAS | – | 12 25 | 08 23 | 20 21 | |
OHP | OMI-GOME-2 | – | 30 27 | 34 34 | 29 34 |
MAX-DOAS | 00 08 | 09 10 | 35 24 | 18 14 | |
Beijing, Xianghe | OMI-GOME-2 | – | 34 31 | 39 67 | 25 32 |
MAX-DOAS | 12 08 | 08 18 | 44 40 | 18 15 | |
Bujumbura | OMI-GOME-2 | 22 26 | 28 23 | 24 41 | 22 40 |
MAX-DOAS | 49 28 | 50 28 | – | – | |
Reunion | OMI-GOME-2 | 14 22 | 13 27 | 16 18 | 14 30 |
FTIR | – | 13 20 | 07 06 | 06 09 |
Vertical columns in China and in Burundi
Validation of GOME-2 and OMI retrievals in Beijing and Xianghe, using MAX-DOAS retrievals (represented by black squares). Upper panel: mid-morning observations (GOME-2 and MAX-DOAS averaged over 8–11 h). Lower panel: early afternoon observations (OMI and MAX-DOAS averaged over 12–15 h). Observations have been averaged per month, over the period 2008–2013, selecting correlative days between GOME-2/OMI and the MAX-DOAS instrument. Satellite measurements have been averaged within 100 km around each location, and filtered using quality criteria as defined in Sect. 3.4. Three satellite VCs are presented: IMAGES a.p. profile/no cloud correction, IMAGES a.p. profile/IPA cloud correction, and MAX-DOAS a.p. profile/IPA cloud correction. Correlation plots are shown for the two latter cases, respectively, in the left and right panels.
[Figure omitted. See PDF]
Validation of GOME-2 and OMI retrievals in Bujumbura, using MAX-DOAS retrievals (represented by black squares). Upper panel: mid-morning observations (GOME-2 AandB and MAX-DOAS averaged over 8–11 h). Lower panel: early afternoon observations (OMI and MAX-DOAS averaged over 12–15 h). Observations have been averaged per month, over the period 2013–2014, selecting correlative days between GOME-2/OMI and the MAX-DOAS instrument. Satellite measurements have been averaged within 100 km around each location, and filtered using quality criteria as defined in Sect. 3.4. Three GOME-2B and OMI VCs are presented: IMAGES a.p. profile/no cloud correction, IMAGES a.p. profile/IPA cloud correction, and MAX-DOAS a.p. profile/IPA cloud correction.
[Figure omitted. See PDF]
Monthly averaged columns retrieved from GOME-2, OMI and MAX-DOAS measurements are shown in Figs. 11 and 12, respectively, for the stations of Beijing/Xianghe (averaged over 2008–2013) and Bujumbura (averaged over 2013–2014). As the instrument in Bujumbura was installed at the end of 2013, we use the more recent HCO columns from GOME-2B, but the GOME-2A columns are shown up to the end of 2013 (light green). The monthly means have been calculated using days in common between, respectively, GOME-2 and morning MAX-DOAS data (08:00–11:00), and OMI and afternoon MAX-DOAS data (12:00–15:00). Again, the satellite observations are averaged within 100 km around each station and filtered as described in Sect. 3.4. In China, the resulting number of correlative days amounts to 711 for GOME-2 and 807 for OMI. In Burundi, we obtain respectively 58 and 90 days over the 5 months of measurements. Quantitative comparisons between GOME-2, OMI and MAX-DOAS columns are provided in Table 5. Three sets of monthly averages are used for the satellites, in order to evaluate uncertainties related to the AMF calculation: (1) the vertical columns calculated using the IMAGES a priori profile shapes and no cloud correction (plain dots), (2) same but applying the IPA to correct for cloud radiative effects (empty dots), and (3) the vertical columns calculated using as a priori the HCO vertical profile shapes retrieved from the MAX-DOAS measurements and the IPA cloud correction (diamonds). In Fig. 11, the lower panels display scatter plots between monthly averaged observations for the satellite retrievals versions (2) and (3). In Beijing/Xianghe, the correlation coefficients are similarly high between the different AMF versions, and slightly better for OMI than GOME-2 (about 0.8 for GOME-2 and 0.9 for OMI). However, the slopes and offests of the regression lines between the satellite and ground-based observations show larger dependency on the AMF calculation settings. We find slopes of respectively 0.8, 0.6 and 0.9 for GOME-2 and 0.6, 0.6 and 1 for OMI. In Bujumbura, the number of ground-based measurements is unfortunately not large enough to draw conclusions about the correlations, and we rather provide the mean differences between the satellite and MAX-DOAS columns. The mean differences are found to be respectively 2.8, 2.6 and 1. molec cm for GOME-2 and 3.3, 2.6 and molec cm for OMI. Results in China and in Burundi suggest that the cloud correction has little systematic influence, and therefore a limited effect on the monthly averaged columns, as indicated by the mean difference variations between (1) and (2) (less than 10 %). On the contrary, the a priori vertical profile has a larger systematic effect on the vertical columns, as indicated by the different results between (2) and (3). Both for GOME-2 and OMI, switching from modelled to measured profile shapes increases the HCO columns by 20 to 50 %, bringing the satellites and ground-based observations to a satisfactory agreement within 15 %. We note that the OMI columns in Beijing/Xianghe present a positive offset of about molec cm. The large effect of the a priori profile shape is explained by the vertical sensitivity of the satellite measurements, decreasing strongly in the lowest atmospheric layers, and by the shape of the HCO vertical distribution, peaking near the surface. This is illustrated in Fig. 13, where the HCO profile shapes modelled by IMAGES and those retrieved from the MAX-DOAS measurements are plotted next to the satellite vertical sensitivity for June 2010 in Xianghe. It must be noted that the retrieved MAX-DOAS profiles also have their own uncertainties (Vlemmix et al., 2014); however, using them to re-calculate the satellite AMFs allows one to remove from the comparison the error associated with the a priori profile shapes (Eskes and Boersma, 2003). Indeed, only the shapes of the a priori profiles impact the satellite AMFs, not their total columns (Palmer et al., 2001). The satellite averaging kernels (AKs) are much closer in shape to the FTIR AKs than to the MAX-DOAS retrievals, which may explain the better agreement of the columns (Vigouroux et al., 2009).
IMAGES CTM and MAX-DOAS retrieved HCO profile shapes (concentration profiles divided by their total columns) averaged in June 2010 in Xianghe. IMAGES prim1 includes an additional primary source, as reported by Chen et al. (2014). The corresponding mean satellite scattering weighting functions are also displayed.
[Figure omitted. See PDF]
Results of the comparisons between GOME2, OMI and MAX-DOAS columns, shown in Fig. 11 for Beijing/Xianghe and in Figure 12 for Bujumbura. Three satellite VCs are used: IMAGES a.p. (a priori) profile/no cloud correction, IMAGES a.p. profile/IPA cloud correction, and MAX-DOAS a.p. profile/IPA cloud correction. Mean differences (satellite–MAX-DOAS) are given in both stations. In Beijing/Xianghe, the slopes and offsets of a linear regression between MAX-DOAS and satellite columns are provided.
GOME-2 | OMI | |||||
---|---|---|---|---|---|---|
IMAGES a.p. profiles | IMAGES a.p. profiles | MAXDOAS a.p. profiles | IMAGES a.p. profiles | IMAGES a.p. profiles | MAXDOAS a.p. profiles | |
No cloud correction | Cloud correction | Cloud correction | No cloud correction | Cloud correction | Cloud correction | |
Beijing/Xianghe | ||||||
No. of common days | 711 | 807 | ||||
Mean difference | ||||||
10 molec cm | 4.4 | 5.4 | 1.4 | 2.8 | 3.4 | 2.1 |
(%) | (33 %) | (41 %) | (11 %) | (19 %) | (24 %) | (15 %) |
Correlation coefficient | 0.82 | 0.85 | 0.84 | 0.88 | 0.87 | 0.88 |
Slope | 0.80 | 0.64 | 0.91 | 0.61 | 0.62 | 0.97 |
Offset | 1.6 | 0.6 | 0.2 | 3.0 | 2.3 | 3.2 |
10 molec cm | ||||||
Bujumbura | ||||||
No. of common days | 58 | 90 | ||||
Mean difference | ||||||
10 molec cm | 2.8 | 2.6 | 1.1 | 3.3 | 2.6 | 0.9 |
(%) | (29 %) | (27 %) | (11 %) | (39 %) | (31 %) | (9 %) |
The effect of the rather coarse resolution of the global CTM on the modelled profiles (here 2 2.5) needs to be further investigated, particularly for anthropogenic sources, as well as other possible effects of vertical transport and chemical processes. For example, a recent analysis of in situ measurements in Beijing (Chen et al., 2014) indicated that primary sources of HCO are responsible for as much as about 32 % of the total HCO source in the area, suggesting a strong underestimation of this direct source in current inventories. In the standard IMAGES simulation using the REASv2 inventory, this primary source contributes less than 1 % of the total HCO source during the summer. Adjusting the primary source in the model to match the direct fraction estimated by Chen et al. (2014) results in the IMAGES profile shapes also shown in Fig. 13 (IMAGES prim1), found to agree much better with MAX-DOAS profiles. It is not clear whether this large apparent contribution of direct emissions is real or reflects e.g. a fast chemical production from highly reactive VOCs currently not well represented in inventories and models. Whatever the reasons might be for the improved model profiles in comparison with MAX-DOAS data, generalisation to other areas would appear premature. It is worth noting that the IMAGES model was found to reproduce very well observed vertical profiles of formaldehyde measured during aircraft campaigns over the United States and over oceans (Stavrakou et al., 2009c). More studies and measurements are required to refine our understanding of factors governing the formaldehyde vertical profiles.
Long-term variations
Formaldehyde columns are mainly formed by oxidation of NMVOCs from biogenic biomass burning and anthropogenic sources. Column inter-annual variabilities are mainly driven by fire events and temperature changes (Millet et al., 2008; Barkley et al., 2009; Stavrakou et al., 2014). However, over industrialised regions, changes in anthropogenic emissions have also been identified as drivers of observed HCO column trends (De Smedt et al., 2010; Zhu et al., 2014; Khokhar et al., 2015; Mahajan et al., 2015; Stroud et al., 2015).
The TEMIS time series of morning HCO columns, consisting of GOME, SCIAMACHY and GOME-2A and GOME-2B data, spans over 15 years of observations, while the afternoon time series derived from OMI covers 10 years of observations. Meaningful trend studies are therefore possible. We used a linear model with a seasonal component to fit the monthly averaged columns separately for the morning and afternoon time series. The error and statistical significance of the inferred trends are also estimated, as described in De Smedt et al. (2010). It is understood that the accuracy of such a trend analysis is limited in the case of HCO because, like for the amplitude of the diurnal variation (between 1 and molec cm, the amplitude of the trends to be detected (about 1– molec cm in 10 years) is 1 order of magnitude smaller than the HCO columns, their errors and their seasonal variations. However, statistically significant trends are detected in several regions independently with both data sets, which gives confidence in our HCO column long-term variation estimates.
Monthly averaged HCO vertical columns as observed from satellite instruments in India and China. Mid-morning columns (in green) consist of SCIAMACHY (2003–2011) and GOME-2A (2007–2013) and GOME-2B (2013– ) measurements. If statistically significant, results of the trend analysis are displayed (De Smedt et al., 2010).
[Figure omitted. See PDF]
Monthly averaged HCO vertical columns as observed from satellite instruments in South America and Africa. Mid-morning columns (in green) consist of SCIAMACHY (2003–2011), GOME-2A (2007–2013) and GOME-2B (2013– ) measurements, while early afternoon columns (in red) are derived from OMI measurements. If statistically significant, results of the trend analysis are displayed (De Smedt et al., 2010).
[Figure omitted. See PDF]
Monthly averaged HCO vertical columns as observed from satellite instruments in US and Europe. Mid-morning columns (in green) consist of SCIAMACHY (2003–2011) and GOME-2A (2007–2013) and GOME-2B (2013– ) measurements, while early afternoon columns (in red) are derived from OMI measurements. If statistically significant, results of the trend analysis are displayed (De Smedt et al., 2010).
[Figure omitted. See PDF]
Figures 14 to 16 present the time series of monthly averaged HCO vertical columns in India, China, South America, Africa, North America and Europe. In those figures, the mid-morning time series (in green) combine SCIAMACHY (2003–2011), GOME-2A (2007–2013) and GOME-2B (from 2013) measurements, while early afternoon columns (in red) are derived from OMI measurements. The good agreement between the different morning observations can be noted (see also De Smedt et al., 2012), as well as the previously described differences and similarities between afternoon and morning time series. In particular, the higher morning columns over tropical forest are also observed in the SCIAMACHY time series. The results of our trend analysis are displayed whenever they have been found statistically significant, i.e. if the absolute value of the calculated trend is larger than twice the associated error. Furthermore, Fig. 17 presents a global map of the most significant trends found in the OMI HCO columns between November 2004 and August 2014. The analysis has been performed at country level on the global scale, at province or state level in the largest countries, and in a radius of 100 km around the main urban areas.
Annual absolute trends observed in the OMI HCO columns between November 2004 and August 2014. The change in the OMI spatial sampling over the years has been taken into account in this trend analysis.
[Figure omitted. See PDF]
For these calculations, “sampling-corrected” OMI columns are used. Indeed, as shown in Fig. 6, the OMI daily spatial sampling has been reduced over the years because of the growing row anomaly. This has an impact on the HCO monthly averaged columns, which tend to decrease in time if this effect is not taken into account. This decrease could be explained by the fact that a large number of central rows (rows 27–44 since January 2009), which have the finest spatial resolution, are affected by the anomaly and need to be filtered out. For this reason, we have calculated special OMI monthly averages, selecting only the rows that were still valid at the end of 2013. The net effect is a slight decrease of the columns at the beginning of the time series, almost negligible when looking at the absolute values, but significant when considering trends.
In India and China (Fig. 14), we observe increasing HCO columns. The spatial distribution of the observed increases, and their values, is similar in the SCIAMACHY-GOME-2 and OMI time series. No trend is observed in the largest Chinese cities like Beijing and in the Pearl River delta. However, large positive trends are detected in the surrounding provinces, located in the centre of the country (e.g. Henan and Hunan provinces). This spatial shift of the Chinese trends outside the largest cities was already reported in De Smedt et al. (2010), using GOME and SCIAMACHY observations between 1997 and 2009. This might be related to a larger influence of newer, cleaner technologies in these mega-cities compared to the Chinese heartland (Zhang et al., 2009). In India, we observe positive trends almost everywhere, with an (absolute and relative) amplitude increasing from the south to north of the country. Values obtained from morning and afternoon observations are found to be consistent, and similar to the ones reported for the period 1997–2009.
In the eastern US and western Europe (Fig. 16), we observe decreasing trends more clearly detected in the OMI retrievals. The morning HCO observations have larger errors and the wintertime observations cannot be used. Negative trends have previously been reported, but with less statistical significance (De Smedt et al., 2010). Here, the correlation between the SCIAMACHY/GOME-2 and OMI observations is found to be good even in these retrieval-sensitive regions, giving some new confidence in the morning time series over northern Europe and North America. The expected negative trends due to emission controls are better captured by the early afternoon observations of OMI, allowing the detection of significant decreases in Germany and France. In southern European countries like Spain, negative trends can be detected in both time series, which show remarkable correlation, with for example very low values in spring 2008 that could be related to power plant emission reductions as reported for NO by Curier et al. (2014).
(a) Monthly averaged HCO vertical columns from SCIAMACHY/GOME2 (in green) and from OMI (in red) (first panel) and (b) MODIS fire count (second panel) over the Rondônia Brazilian state. Inset values are the correlation coefficient between the satellite HCO columns and the fire counts. (c) Reported yearly deforestation rates in selected Brazilian states, relative to their respective surfaces (third panel; source: Brazil INPE). Inset values are the total surface of the state and the total rate of deforestation between 1988 and 2013.
[Figure omitted. See PDF]
Over the African continent (right panels of Fig. 15), almost no change is detected, with the exception of Madagascar, and its capital Antananarivo, where a large positive trend is found in the OMI time series. The origin of this trend is not understood for the moment. No similar increase has been reported in satellite NO observations over this region (see for example Hilboll et al., 2013). In South America (left panels of Fig. 15), we observe very significant negative trends over the Brazilian state of Rondônia, of molec cm yr, in both morning and afternoon time series. Such negative trends are also present, with lower amplitudes, in the surrounding Brazilian states covered by the Amazon forest. The largest HCO columns worldwide are observed in those regions, with very large variations between the dry and the wet season (see Table 2). Figure 18 shows the HCO columns in Rondônia between 2003 and 2014, the MODIS (on Terra and Aqua satellites) Collection 5 Active Fire Product (ftp://fuoco.geog.umd.edu/modis/C5/cmg, Giglio, 2013), and the yearly deforestation rates reported by the Brazilian INPE (http://www.obt.inpe.br/prodes/index.php), in selected Amazonian states. Deforestation in Rondônia amounted to 23 % of its surface area between 1988 and 2013. This is the highest surface ratio among all Brazilian states. The years showing the highest deforestation rates are 1995 and 2004. In Rondônia, a strong decrease of the deforestation rate has been observed between 2005 and 2010, and a slight increase is again observed since 2011. As illustrated by the middle panel of Fig. 18, we find high correlation coefficients between the SCIAMACHY/GOME-2 and OMI HCO columns and the MODIS fire product, of respectively 0.8 and 0.9 (see also Barkley et al., 2013). We have also compared the HCO vertical columns with GISS surface temperature anomalies (Gridded Monthly Maps of Temperature Anomaly Data, http://data.giss.nasa.gov/gistemp/; Hansen et al., 2010), but no correlation was found in this area. Vegetation burning related to deforestation appears to have strongly decreased in Rondônia, while it is not yet the case in the surrounding areas. It should be noted that the strong enhancement of natural fire emissions during very dry years (such as 2005 and 2010) somehow reduces the observed downward trend in the fires and HCO columns, and therefore the correlation with the reported deforestation rates.
Besides these direct effects of biomass burning activity changes on the HCO columns, more studies are needed in order to assess the impact of deforestation and land use changes, and possibly related meteorological changes, on biogenic NMVOC emissions (Stavrakou et al., 2014). It is worth noting that BIRA-IASB is currently installing a FTIR instrument in Porto Velho, in the Rondônia state. This will bring new information on both the diurnal cycle of HCO columns and its chemistry, and more generally, on the carbon cycle molecules (CO, CH, CO and NMVOCs).
Conclusions
This paper presents a new version of the BIRA-IASB formaldehyde retrieval algorithm that has been applied to the complete time series of OMI and GOME-2 measurements and delivered for public use on the TEMIS website. Our focus is the continuity and the consistency of the HCO data set, as well as a good characterisation of the satellite observations. The spectral fits have been improved by means of a better treatment of the interference between O, BrO and HCO differential structures, resulting in HCO columns of higher accuracy and precision. Daily remote radiance spectra are used as DOAS reference, and a destriping procedure is included in the background sector correction, reducing the impact of the OMI row anomaly, but also the GOME-2 across-track variability. Daily morning and afternoon a priori profiles are provided by a state-of-the-art version of the IMAGES global CTM.
The GOME-2 and OMI HCO data sets agree very well qualitatively, in terms of both long-term variations and seasonal variations. Vertical columns also agree reasonably well, although systematic differences are observed, depending on the geographical location. The morning HCO observations are higher than the afternoon observations over tropical rainforests of the Amazon basin, Africa, and Indonesia. The OMI observations are larger than the GOME-2 columns over urban areas (pointing to a horizontal resolution effect) and more generally over all mid-latitude regions (pointing to a combination of actual diurnal variation effects and differences in retrieval sensitivities between morning and afternoon observations).
A detailed validation study has been performed using correlative ground-based MAX-DOAS measurements in Belgium/Netherlands, southern France, north-eastern China, Burundi and FTIR measurements in Reunion. We show that the differences observed between the GOME-2 and OMI HCO columns are mainly consistent with the diurnal variations observed from the ground, within the error bars of the satellite and ground-based observations. In Beijing/Xianghe and Bujumbura, MAX-DOAS vertical profiles have been used to re-calculate the satellite air mass factors, allowing one to eliminate from the comparison the error coming from the a priori profiles. By doing so, the satellite and MAX-DOAS columns are found to agree to within 15 % or better.
To conclude, while the precision is driven by the signal-to-noise ratio of
the recorded spectra, the accuracy is limited by our current knowledge of the
external parameters needed for the retrieval, mainly the a priori profile
shapes and their diurnal variation and the cloud and aerosol properties. To
fully exploit the potential of satellite data, scientific studies relying on
tropospheric HCO observations require consistently retrieved long-term
time series, provided with well-characterised errors and averaging kernels.
In the framework of prototype algorithm developments for the future TROPOMI
instrument to be flown on the ESA Copernicus Sentinel-5 Precursor mission, we
are currently investigating the impact of using global CTM profiles on a
finer horizontal resolution. Verification and validation studies are ongoing
with the aim of further improving the retrieval algorithms. Furthermore, in
the context of the EU QA4ECV project (
Acknowledgements
The HCO data products from GOME-2 were generated at BIRA using level-1 data developed by EUMETSAT. Level-2 and level-3 HCO scientific products from GOME-2 have been jointly supported by Belgian PRODEX (A3C and TRACE-S5P), ESA (PROMOTE) and EU (AMFIC). BIRA is also involved in the O3MSAF (CDOP-2 project), where it supports the development and validation of the GOME-2 HCO operational product generated at DLR. The HCO data products from OMI were generated at BIRA using level-1 data developed at NASA/KNMI. Level-2 and level-3 OMI HCO developments are supported as part of the Sentinel-5 precursor TROPOMI level-2 project, funded by ESA and Belgian PRODEX (TRACE-S5P project). Multi-sensor HCO developments at BIRA are currently supported by EU FP7 (QA4ECV project), in cooperation with KNMI, the University of Bremen and MPIC-Mainz. Modelling at BIRA was funded by the Belgian PRODEX projects A3C and ACROSAT. MAX-DOAS measurements were funded by Belgian Federal Science Policy Office, Brussels (AGACC-II project), the EU 7th Framework Programme projects NORS and ACTRIS, and the ESA CEOS Intercalibration project. Acknowledgements are addressed to the Université de La Réunion and CNRS (LACy-UMR8105 and UMS3365) for their support of the OPAR station and the OSU-R activities.Edited by: T. von Clarmann
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
© 2015. This work is published under http://creativecommons.org/licenses/by/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Abstract
We present the new version (v14) of the BIRA-IASB algorithm for the retrieval of formaldehyde (H
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details



1 Belgian Institute for Space Aeronomy (BIRA-IASB), Brussels, Belgium
2 Royal Netherlands Meteorological Institute (KNMI), De Bilt, the Netherlands