Abstract
Background
The aim of the German Medical Informatics Initiative is to establish a national infrastructure for integrating and sharing health data. To this, Data Integration Centers are set up at university medical centers, which address data harmonization, information security and data protection. To capture patient consent, a common informed consent template has been developed. It consists of different modules addressing permissions for using data and biosamples. On the technical level, a common digital representation of information from signed consent templates is needed. As the partners in the initiative are free to adopt different solutions for managing consent information (e.g. IHE BPPC or HL7 FHIR Consent Resources), we had to develop an interoperability layer.
Methods
First, we compiled an overview of data items required to reflect the information from the MII consent template as well as patient preferences and derived permissions. Next, we created entity-relationship diagrams to formally describe the conceptual data model underlying relevant items. We then compared this data model to conceptual models describing representations of consent information using different interoperability standards. We used the result of this comparison to derive an interoperable representation that can be mapped to common standards.
Results
The digital representation needs to capture the following information: (1) version of the consent, (2) consent status for each module, and (3) period of validity of the status. We found that there is no generally accepted solution to represent status information in a manner interoperable with all relevant standards. Hence, we developed a pragmatic solution, comprising codes which describe combinations of modules with a basic set of status labels. We propose to maintain these codes in a public registry called ART-DECOR. We present concrete technical implementations of our approach using HL7 FHIR and IHE BPPC which are also compatible with the open-source consent management software gICS.
Conclusions
The proposed digital representation is (1) generic enough to capture relevant information from a wide range of consent documents and data use regulations and (2) interoperable with common technical standards. We plan to extend our model to include more fine-grained status codes and rules for automated access control.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer