This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
1. Introduction
When a tooth is extracted, the healing of the socket inevitably involves reshaping of the periodontal alveolar process with horizontal and vertical bone loss. Postextraction immediate implant placement has been proven to be a reliable and safe process, with an osseointegration success rate similar to that of conventional implants, but it does not prevent bone remodeling after extraction [1]. It has also been suggested that various regenerative treatments, such as soft or hard tissue grafts, help to compensate this alveolar process reduction [1, 2].
Among bone grafts that have been studied for immediate implantology, we can find allogenic, xenogenic, and alloplastic grafts. All of them are successful, and they have minimal differences in reabsorption [1].
The socket shield technique (SST) was published for the first time in 2010 as a feasible technique to avoid buccal bone reshaping after tooth extraction, in combination with immediate implant placement. A thin buccal and interproximal layer or fragment of the tooth needs to be maintained in order to avoid buccal bone resorption [3].
2. Objectives
The purpose of this article is to present a clinical case of a patient who underwent immediate implant placement with the SS technique in the superior aesthetic area.
3. Case Report
A 50-year-old man was referred to us having a decemented bridge from 1.2 to 2.2, with inadequate ferrule and metal posts in each root (1.1 and 2.2), both fractured (Figures 1 and 2). Given this miserable condition of the roots and their poor prognosis, rehabilitation of the area with fixed prostheses supported by two implants was proposed.
[figure omitted; refer to PDF]
The socket shield technique was performed on central incisors and pontic shield on lateral incisors (Figure 3) in order to minimize resorption and reshaping of the bone crest in implants and pontics. Haemostatic collagen sponges were placed both in 1.2 and in 2.2, and immediate implant placement was performed in 1.1 and 2.1 (Figures 4 and 5). In order to keep anterior guidance, lateral incisors were planned in cantilever, contactless during disclusion movements.
[figure omitted; refer to PDF]
Two Biohorizons Tapered Internal
[figure omitted; refer to PDF]
Three months after, the osseointegration of the implants was corrected (Figure 7), but teeth 1.1 had a superficial exposure of the shield (Figure 8), which was reshaped with the high-speed handpiece using a diamond bur, without needing anesthesia. After one more month, the clinical appearance was corrected (Figure 9) and a partial fixed denture was screwed at 30 N/cm to the implant (Figures 10 and 11). Good maintenance of buccal volume and natural appearance is seen (Figure 12).
[figure omitted; refer to PDF]
These partial extraction techniques have allowed us to maintain the volume of the buccal crest without the need to fill the gap with bone grafts and give the gingiva a natural appearance.
The authors want to emphasize that the value of this study is limited, since it is a case report of a single patient.
4. Discussion
Already in 2009, Davarpana and Szmukler-Moncler [4] presented a limited series of 5 cases with a follow-up between 12 and 42 months, in which the implants were drilled and placed through the roots of ankylosed teeth, leaving the fragments that remained stable in the socket. They found no complications derived from tooth remains in contact with the implant, and the cases were successful throughout the follow-up. They present the technique as an alternative to tooth extraction when it can cause morbidity.
Several studies have been published regarding the socket shield technique since its first reference by Hürzeler et al. [3]. Thus, Kan and Rungcharassaeng [5] and later Cherel and Etienne [6] used the SST in order to preserve the interdental papilla in between implants, in cases where adjacent teeth need to be restored.
Siormpas et al. [7] conducted a study on 46 patients with single implants, performing the “root-membrane” technique, similar to the TSS, and leaving the vestibular fragment at least 1 millimeter above the bone level and in contact with the implant surface. They obtained 100% success in a follow-up between 24 and 60 months and correct maintenance of the buccal bone volume. They concluded that it is a predictable technique for the placement of implants in aesthetic areas in healthy adults.
Gluckman et al. [8] described the pontic shield technique in which they performed a treatment similar to SST but, in these cases, filling the socket with xenogeneic graft in the pontics. Among the presented series, 13 cases were successful and one case required reshaping and advancement flap due to shield exposure. They conclude their study, describing the technique as a feasible option in bone preservation in pontics and assuming the need for more studies in this regard.
Afterwards, the same authors (in 2016 [9] and 2017 [10]) carried out two consecutive studies. The first study defined partial extraction techniques in three groups: (i) root submergence when the entire root volume is kept under the gum to preserve the volume, being very important the fact that the teeth do not have apical pathology; (ii) socket shield as a preparation of the root’s buccal surface and 1 mm above the bony crest in anterior teeth and with simultaneous placement of immediate implants in the palatal surface of the socket, having eliminated any possible apical pathology before; (iii) pontic shield, which means preparing the socket shield exactly the same as SST but recommends filling the socket with osteoconductive material. They also advise soft tissue sealing and a three-month follow-up before pressing with ovoid pontics. Table 1 shows the indications for the different partial extraction techniques based on this study and review. The study finishes by concluding that partial extraction techniques should be considered by clinicians as a conservative strategy to maintain bone crest in oral rehabilitation [9].
Table 1
Partial extraction therapies (PET) and their indications, adapted from Siormpas et al. [7].
PET | Clinical situation(s) indicated |
Root submergence | (i) Unrestorable tooth crown or tooth indicated for extraction absence of apical pathology |
Socket shield | (i) Unrestorable tooth crown or tooth indicated for extraction tooth root with or without apical pathology |
Pontic shield | (i) Unrestorable tooth crown or tooth indicated for extraction tooth root with or without apical pathology |
Proximal socket shield | (i) Unrestorable tooth crown or tooth indicated for extraction tooth root with or without apical pathology |
In his second work, he focuses on the technical aspects and the management of complications. The necessary materials for partial extraction techniques described in this article are presented in Table 2. They conclude by defining partial extraction techniques as a very promising set for the future management of bone ridges after the removal of nonpreservable teeth [10].
Table 2
Instruments and materials required for PET [8].
Socket shield |
(1) Long shank root resection bur |
Pontic shield |
(1) Socket grafting instruments: plugger, particulate graft spoon, crucible |
Root submergence |
(1) Irrigated surgical motor |
In 2017, Gharpure & Bhatavadekar wrote in a systematic review reporting limited scientific support regarding TSS, with evidence of less osseointegration, some biological complications and short follow-up cases. They suggest the need of more studies to obtain scientific support [11]. More recently, Han et al. [12] presented a modified TSS with a series of 40 implants maintaining the buccal shield at bone crest level and with an approximate thickness of 1.5 mm, without biological complications and with a 100% success rate. They conclude that modified TSS appears to be a successful procedure combined with immediate implants because the root surface does not interfere with osseointegration and is beneficial for the aesthetics and maintenance of bone.
Bramanti et al. [13] reported a sample of forty patients who received an immediate single implant in the esthetic zone with SST versus immediate implants with the conventional technique and filling the gap with bone graft. No clinical complications were recorded at 3, 6, and 36 months from implant placement. A lower rate of crestal bone resorption was recorded in the TSS group in all checks over time.
Based on the published studies and the case we present, we can confirm that complications arise more easily when the tooth fragment remains above the bone crest. The filling of the socket does not seem necessary when performing this technique since the blood clot achieves a regeneration of the socket and the shield prevents buccal reshaping.
5. Conclusion
The conclusion that we can draw from this case report and the subsequent review of the literature is that partial extraction techniques, such as the socket shield and the pontic shield, are procedures that should be considered in oral rehabilitation in selected cases.
This kind of intervention is dependent on the surgical technique of the operator, and its reproducibility must be assessed.
[1] J. Majzoub, A. Ravida, T. Starch-Jensen, M. Tattan, F. Suárez-López del Amo, "The Influence of Different Grafting Materials on Alveolar Ridge Preservation: a Systematic Review," Journal of Oral and Maxillofacial Research, vol. 10 no. 3, article e6,DOI: 10.5037/jomr.2019.10306, 2019.
[2] M. G. Araújo, C. O. Silva, A. B. Souza, F. Sukekava, "Socket healing with and without immediate implant placement," Periodontology 2000, vol. 79 no. 1, pp. 168-177, DOI: 10.1111/prd.12252, 2019.
[3] M. B. Hürzeler, O. Zuhr, P. Schupbach, S. F. Rebele, N. Emmanouilidis, S. Fickl, "The socket-shield technique: a proof-of-principle report," Journal of Clinical Periodontology, vol. 37 no. 9, pp. 855-862, DOI: 10.1111/j.1600-051X.2010.01595.x, 2010.
[4] M. Davarpanah, S. Szmukler-Moncler, "Unconventional implant treatment: I. Implant placement in contact with ankylosed root fragments. A series of five case reports," Clinical Oral Implants Research, vol. 20 no. 8, pp. 851-856, DOI: 10.1111/j.1600-0501.2008.01653.x, 2009.
[5] J. Y. K. Kan, K. Rungcharassaeng, "Proximal socket shield for interimplant papilla preservation in the esthetic zone," The International Journal of Periodontics & Restorative Dentistry, vol. 33 no. 1, pp. e24-e31, DOI: 10.11607/prd.1346, 2013.
[6] F. Cherel, D. Etienne, "Papilla preservation between two implants: a modified socket-shield technique to maintain the scalloped anatomy? A case report," Quintessence International, vol. 45 no. 1, pp. 23-30, DOI: 10.3290/j.qi.a30765, 2014.
[7] K. D. Siormpas, M. E. Mitsias, E. Kontsiotou-Siormpa, D. Garber, G. A. Kotsakis, "Immediate implant placement in the esthetic zone utilizing the "root-membrane" technique: clinical results up to 5 years postloading," The International Journal of Oral & Maxillofacial Implants, vol. 29 no. 6, pp. 1397-1405, DOI: 10.11607/jomi.3707, 2014.
[8] H. Gluckman, J. Du Toit, M. Salama, "The pontic-shield: partial extraction therapy for ridge preservation and pontic site development," The International Journal of Periodontics & Restorative Dentistry, vol. 36 no. 3, pp. 417-423, DOI: 10.11607/prd.2651, 2016.
[9] H. Gluckman, M. Salama, J. Du Toit, "Partial extraction therapies (PET) part 1: maintaining alveolar ridge contour at pontic and immediate implant sites," The International Journal of Periodontics & Restorative Dentistry, vol. 36 no. 5, pp. 681-687, DOI: 10.11607/prd.2783, 2016.
[10] H. Gluckman, M. Salama, J. Du Toit, "Partial extraction therapies (PET) part 2: procedures and technical aspects," The International Journal of Periodontics & Restorative Dentistry, vol. 37 no. 3, pp. 377-385, DOI: 10.11607/prd.3111, 2017.
[11] A. S. Gharpure, N. B. Bhatavadekar, "Current evidence on the socket-shield technique: a systematic review," The Journal of Oral Implantology, vol. 43 no. 5, pp. 395-403, DOI: 10.1563/aaid-joi-D-17-00118, 2017.
[12] C.-H. Han, K.-B. Park, F. G. Mangano, "The modified socket shield technique," Journal of Craniofacial Surgery, vol. 29 no. 8, pp. 2247-2254, DOI: 10.1097/SCS.0000000000004494, 2018.
[13] E. Bramanti, A. Norcia, M. Cicciù, G. Matacena, G. Cervino, G. Troiano, K. Zhurakivska, L. Laino, "Postextraction dental implant in the aesthetic zone, socket shield technique versus conventional protocol," The Journal of Craniofacial Surgery, vol. 29 no. 4, pp. 1037-1041, DOI: 10.1097/SCS.0000000000004419, 2018.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Copyright © 2020 Carlos Polis-Yanes et al. This is an open access article distributed under the Creative Commons Attribution License (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License. https://creativecommons.org/licenses/by/4.0/
Abstract
When a tooth is extracted, a bone remodeling of the alveolar process occurs irretrievably. Various techniques have emerged over time to maintain the thickness of the bone crest in fixed prosthetics on teeth and implants. The socket shield and pontic shield techniques are aimed at minimizing buccal bone remodeling, especially in the aesthetic area. We present a case of an aesthetic sector rehabilitated with partial fixed denture using the socket shield and pontic shield techniques.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details


1 School of Dentistry, University of Barcelona, University Campus of Bellvitge, Barcelona, Spain
2 School of Dentistry, University of Barcelona, Oral Health and Masticatory System Group (Bellvitge Biomedical Research Institute) IDIBELL, University of Barcelona, University Campus of Bellvitge, L’Hospitalet de Llobregat, Barcelona, Spain
3 Department of Maxillofacial Surgery, University Hospital of Bellvitge, Catalonia, Spain; Oral Health and Masticatory System Group (Bellvitge Biomedical Research Institute) IDIBELL, University of Barcelona, L’Hospitalet de Llobregat, Barcelona, Spain
4 Department of Odontostomatology, Faculty of Medicine and Health Sciences (Dentistry), Odontological Hospital University of Barcelona-University of Barcelona/Oral Health and Masticatory System Group (Bellvitge Biomedical Research Institute) IDIBELL, University of Barcelona, L’Hospitalet de Llobregat, Barcelona, Spain