Content area

Abstract

Purpose

For this retrospective cohort study, we assessed pertrochanteric fracture types AO/OTA 31-A2. PFNA and DHS were the devices used. We determined both devices in relation to peri-operative variables, postoperative radiographic measurements, implant-related complications and mortality up to 2 years. The null hypothesis was no effect between the two devices.

Methods

This single-centre study was conducted based on our computerized data. The treatment period ranged from 2006 to 2015. Only patients with type AO/OTA 31-A2 fractures and an age ≥ 65 years were included. Apart from descriptive variables, the following measurements were assessed: (1) duration of surgery, (2) blood loss, (3) transfusion, (4) hospitalization, (5) tip-apex distance (TAD), (6) fracture reduction, (7) screw position, (8) implant-related complications, and (9) mortality. The follow-up was 2 years for each living patient. Missing data were evaluated by telephone call.

Results

A total of 375 consecutive patients were enrolled into three groups: (1) 75 patients treated with DHS and antirotation screw (ARS); (2); 100 patients treated with DHS + ARS + TSP (trochanteric stabilization plate); and (3) 200 patients treated with PFNA. Apart from dementia, the descriptive data (e.g., age and BMI) demonstrated no effects between the three groups. Compared to PFNA, DHS with or without TSP was adversely affected by a longer operation time, higher blood loss, increase in transfusion, and more implant-related complications including cut-out, infection and failure. The rate of cut-out was significantly higher in TAD ≥ 25 mm (p = 0.005), and PFNA demonstrated significantly better TAD measurements (p = 0.001), better fracture reduction (0.002), more central-central screw positions (p = 0.014), and less poor screw placement (p = 0.001). The mortality rate was without effect between the three groups (log rank 0.698).

Conclusions

DHS with or without TSP was associated with significantly higher rates of implant-related complications based on inferior radiographic measurements. Therefore, we only recommend PFNA for the treatment of proximal type AO/OTA 31-A2 femoral fractures.

Level of evidence

Therapeutic level III.

Details

Title
PFNA and DHS for AO/OTA 31-A2 fractures: radiographic measurements, morbidity and mortality
Author
Müller, Franz 1   VIAFID ORCID Logo  ; Doblinger Matthias 1 ; Kottmann Tanja 2 ; Füchtmeier Bernd 1 

 Hospital Barmherzige Brüder, Clinic for Trauma, Orthopaedic and Sports Medicine, Regensburg, Germany 
 Medical Statistics, Hamm, Germany 
Pages
947-953
Publication year
2020
Publication date
Oct 2020
Publisher
Springer Nature B.V.
ISSN
1863-9933
e-ISSN
1863-9941
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2471707069
Copyright
© Springer-Verlag GmbH Germany, part of Springer Nature 2019.