It appears you don't have support to open PDFs in this web browser. To view this file, Open with your PDF reader
Abstract
In this paper, the optimal allocation of constant and switchable capacitors is presented simultaneously in two operation modes, grid-connected and islanded, for a microgrid. Different load levels are considered by employing non-dispatchable distributed generations. The objective function includes minimising the energy losses cost, the cost of peak power losses, and the cost of the capacitor. The optimization problem is solved using the spotted hyena optimizer (SHO) algorithm to determine the optimal size and location of capacitors, considering different loading levels and the two operation modes. In this study, a three-level load and various types of loads, including constant power, constant current, and constant impedance are considered. The proposed method is implemented on a 24-bus radial distribution network. To evaluate the performance of the SHO, the results are compared with GWO and the genetic algorithm (GA). The simulation results demonstrate the superior performance of the SHO in reducing the cost of losses and improving the voltage profile during injection and non-injection of reactive power by distributed generations in two operation modes. The total cost and net saving values for DGs only with the capability of active power injection is achieved 105,780 $ and 100,560.54 $, respectively and for DGs with the capability of active and reactive power injection is obtained 89,568 $ and 76,850.46 $, respectively using the SHO. The proposed method has achieved more annual net savings due to the lower cost of losses than other optimization methods.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details
1 Universiti Teknologi Malaysia, Institute of High Voltage and High Current, School of Electrical Engineering, Faculty of Engineering, Johor Bahru, Malaysia (GRID:grid.410877.d) (ISNI:0000 0001 2296 1505)
2 Islamic Azad University, Young Researchers and Elite Club, Borujerd Branch, Borujerd, Iran (GRID:grid.464594.e) (ISNI:0000 0004 0493 9891); Aerospace Research Institute, Ministry of Science, Research and Technology, Tehran, Iran (GRID:grid.494521.f) (ISNI:0000 0004 0494 3639)
3 Islamic Azad University, Science and Research, Tehran Branch, Tehran, Iran (GRID:grid.411463.5) (ISNI:0000 0001 0706 2472)
4 Aerospace Research Institute, Ministry of Science, Research and Technology, Tehran, Iran (GRID:grid.494521.f) (ISNI:0000 0004 0494 3639)
5 Golestan Technical and Vocational Training Center, Gorgan, Iran (GRID:grid.494521.f)
6 Islamic Azad University, Khalkhal Branch, Department of Electrical Engineering, Khalkhal, Iran (GRID:grid.494521.f)