This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
1. Introduction
Due to its noncontact isolation measurement, high precision, and low cost [1, 2], current sensors are widely used in power electronic systems, such as photovoltaics, wind power, and electric vehicles, and the use of current sensors has increased year by year. A magnetic field is generated by the measured current. The magnetic field can be measured using different sensor technologies including Hall effect sensor, magnetic fluxgate, and magnetoresistance (MR) sensor. The MR sensors have grabbed the attention of researchers in recent years due to their high sensitivity. The latest research in this field mainly includes anisotropic magnetoresistance (AMR), giant magnetoresistance (GMR), and TMR. Hall, AMR, GMR, and TMR have been used in current sensors [3–6]. Hall has the inherent defects of low sensitivity, high power consumption, and poor linearity. Although the sensitivity of AMR and GMR is much higher than that of hall, their linear range is narrow. Compared with hall, AMR, and GMR, TMR has better temperature stability, higher sensitivity, lower power consumption, and better linearity. The conventional busbar current sensor with differential structure adopts a pair of hall sensors on the conductor surface, which partially suppresses the external magnetic field [7–9]. A busbar with an amphitheater hole is shown [10], and an AMR busbar current sensor is described [6]. Circular sensor array is also a commonly used measurement method. Its accuracy is less dependent on the position of the conductor, and it has better resistance to external magnetic field interference [11, 12]. The disadvantage of circular arrays is that they are too large. In previous research literature, each magnetic sensing device is separately amplified and measured, and then the measured current value is obtained by comprehensive calculation and fitting [13]. The existing method is complicated, and the cost is high. Since the TMR itself is a magnetoresistance device, the magnetoresistances can be connected in parallel. In this paper, four TMRs are directly connected in parallel.
The TMR sensor is a thin film element in which a barrier layer consisting of a thin insulator is sandwiched between two ferromagnetic layers (free layer/pin layer). Due to the wave-like nature of electrons, electrons in the ferromagnetic layer can tunnel through the insulator layer, and the possibility of tunneling through is related to the magnetization of pin and the free layer. The magnetization direction of the pin layer is fixed, and the magnetization direction of free layer changes with the direction of the external magnetic field. When the direction of magnetization of the pin layer is parallel to that of the free layer, the resistance is minimal, since the electron tunneling is the largest and vice versa. Obviously, the TMR element has a sensitive orientation due to pin layer magnetization fixation. In this paper, the sensitive direction of all TMR chips is parallel to the surface and set to the
[figures omitted; refer to PDF]
[figures omitted; refer to PDF]
Therefore, the resistance (
The new type of current sensor proposed in this paper adopts the TMR array, with flexible differential structure and no magnetic core, and is suitable for current measurement in different ranges. The use of nonmagnetic core solution can effectively reduce the volume and weight. Differential structure current sensors are used to partially suppress the external magnetic field interference and improve the test accuracy. We present a new small volume current sensor with the characteristics of the nonintrusive installation. The supply voltage is 5 V, the rated current measurement range is ±300 A, and the peak current measurement range is ±600 A, corresponding to
2. Sensor Design
2.1. Busbar Current Sensor
The TMR and PGA chips are soldered on the printed circuit board (PCB). The four TMR chips are connected in differential mode and then connected to the PGA input port. PGA is used to adjust the gain and temperature characteristics of the current sensor. For the current sensor, TMR and PGA used in this paper manufactured by Sinomags Technology Co., Ltd. in China. We design and test the performance of TMR and PGA and give the test data of the current sensor in this paper.
Figure 1 shows the photo of the current sensor and the schematic diagram of the differential structure of the module. The
The sensitivity of TMR is typically 0.1 m
[figure omitted; refer to PDF]
The equivalent circuit of each TMR and PGA connection is shown in Figure 5.
[figures omitted; refer to PDF]
Ideally, the resistance values of the four resistors of TMR chips in the same wafer are equal. The same goes for the sensitivity.
Each
The equivalent circuit of TMR in the magnetic flux density is shown in Figure 6.
[figures omitted; refer to PDF]
The equivalent circuit of the busbar current sensor is shown in Figure 7.
[figure omitted; refer to PDF]
Equations (4)–(6) and (17)–(20) can be calculated to obtain equation (21). The
The equivalent circuit of the busbar current sensor in the external magnetic flux density is shown in Figure 8.
[figure omitted; refer to PDF]
Therefore, it can be concluded from equation (24) that under the constant external magnetic field interference, the output of the current sensor does not change, which meets the requirement of the resisting external constant magnetic field interference.
In Figure 1, when the measured busbar is passed with 600 A current without an external interference busbar, it can be obtained from Figure 3 that the equivalent differential magnetic field strength of the current sensor is 19.52 Gs. When the measured busbar and the interference busbar with the same size are passed with 600 A current in the same direction, the equivalent differential magnetic field strength of the current sensor is 19.80 Gs. The interference error of the current sensor is 1.4%. When
3. Results
The maximum magnetic flux density generated by the dc 600 A current near TMR is less than 200 Gs, in the good working linear range of TMR.
Figure 9 shows the measurement system which includes current source, power supply, multimeter, PC, and data acquisition card which includes microcontroller unit (MCU), analog-to-digital converter (ADC), RS232, and RS485. The MCU is S9S08DZ60F2MLH made by NXP semiconductors, and the ADC is AD7194BCPZ made by Analog Devices, Inc. The dc current source is XF30ZA-1 K, which is manufactured by Tsinghua Science and Technology Development Co., Ltd., China, with a typical accuracy of ±0.02%, which can meet the requirements of current sensor testing in Table 1.
[figures omitted; refer to PDF]
Table 1
Test instruments.
Device | Model | Manufacturer |
DC current source | XF30ZA-1 K | Tsinghua Science and Technology Development Co., Ltd. |
Power supply | GPD-3303S | Guwei Electronics Co., Ltd. |
Multimeter | DMM4050 | Tektronix |
PC | RK-610 | ADLINK |
Data acquisition card | SMDAQ-6000 | Sinomags Technology Co., Ltd. |
High-low temperature | RGDJ-500 | Surui Test Equipment Co., Ltd. |
Figure 10 shows the
[figures omitted; refer to PDF]
Using the default configuration of the multimeter DMM4050, a sampling period of 0.5 s, sampling for 50 s, to test the noise of the current sensor. Figure 11 shows the noise RMS (root mean square) of the current sensor that is about ±1 mV. The good noise characteristic of the sensor is the guarantee of the good accuracy of the sensor.
[figure omitted; refer to PDF]
Figure 12(a) shows the offset of the current sensor in the full temperature zone. The change of offset in the full temperature zone relative to 25°C is not more than ±10 mV. The sensitivity change in the full temperature zone relative to 25°C is less than ±1% in Figure 12(b). Figure 12(c) shows the relative accuracy of current sensor relative to 25°C in the full temperature zone. The relative accuracy of the current sensor in the full temperature range is within ±1%. So, the current sensor has good temperature characteristics.
[figures omitted; refer to PDF]
4. Conclusions
This paper designs a new type of small volume dc current sensor, which has the characteristics of small volume, flexible installation, and high precision. The current sensor adopts a new differential combination scheme, which has good linearity and anti-interference ability. The current sensor adopts an open-closed structure for easy nonintrusive installation. Compared with the traditional magnetic current sensor and ring array sensor, the new sensor has a smaller volume. The size of the current sensor can be adjusted flexibly according to the size of the busbar. The relative accuracy of the current sensor in the full temperature range is within ±1%. It is very suitable for the dc busbar power system and has a broad application prospect.
Acknowledgments
The authors would like to thank H.Y. Chen, X.G. Yao, J.M. Bai, K. Tan, C. Gao, and J.J. Feng. This work went well under their help.
[1] C. Xiao, L. Zhao, T. Asada, W. G. Odendaal, J. D. van Wyk, "An overview of integratable current sensor technologies," 38th IAS Annual Meeting on Conference Record of the Industry Applications Conference, pp. 1251-1258, .
[2] S. Ziegler, R. C. Woodward, H. H. C. Iu, L. J. Borle, "Current sensing techniques: a review," IEEE Sensors Journal, vol. 9 no. 4, pp. 354-376, DOI: 10.1109/JSEN.2009.2013914, 2009.
[3] H. Zhang, F. Li, H. Guo, Z. Yang, N. Yu, "Current measurement with 3-D coreless TMR sensor array for inclined conductor," IEEE Sensors Journal, vol. 19 no. 16, pp. 6684-6690, DOI: 10.1109/JSEN.2019.2914939, 2019.
[4] I. Jedlicska, R. Weiss, R. Weigel, "Increasing the measurement accuracy of GMR current sensors through hysteresis modeling," 2008 IEEE International Symposium on Industrial Electronics, pp. 884-889, .
[5] L. Cristaldi, A. Ferrero, M. Lazzaroni, R. T. Ottoboni, "A linearization method for commercial hall-effect current transducers," IEEE Transactions on Instrumentation and Measurement, vol. 50 no. 5, pp. 1149-1153, DOI: 10.1109/19.963175, 2001.
[6] Z. Zhenhong, O. Syuji, A. Osamu, K. Hideto, "Development of the highly precise magnetic current sensor module of +/-300 A utilizing AMR element with bias-magnet," IEEE Transactions on Magnetics, vol. 51 no. 1, 2015.
[7] "CSA-1V Melexis Datasheet," . June 2013, https://www.melexis.com
[8] M. Blagojevic, U. Jovanovic, I. Jovanovic, D. Mancic, R. S. Popovic, "Coreless open-loop current transducers based on hall effect sensor CSA-1V," Facta Universitatis Series: Electronics and Energetics, vol. 29 no. 4, pp. 489-507, 2016.
[9] M. Blagojevic, U. Jovanovic, I. Jovanovic, D. Mancic, R. S. Popovic, "Realization and optimization of bus bar current transducers based on Hall effect sensors," Measurement Science and Technology, vol. 27 no. 6,DOI: 10.1088/0957-0233/27/6/065102, 2016.
[10] P. Ripka, M. Pribil, V. Petrucha, V. Grim, K. Draxler, "A fluxgate current sensor with an amphitheater Busbar," IEEE Transactions on Magnetics, vol. 52 no. 7, pp. 53-58, 2016.
[11] L. Di Rienzo, Z. Zhang, "Spatial harmonic expansion for use with magnetic sensor arrays," IEEE Transactions on Magnetics, vol. 46 no. 1, pp. 53-58, DOI: 10.1109/TMAG.2009.2027899, 2010.
[12] R. Weiss, R. Makuch, A. Itzke, R. Weigel, "Crosstalk in circular arrays of magnetic sensors for current measurement," IEEE Transactions on Industrial Electronics, vol. 64 no. 6, pp. 4903-4909, DOI: 10.1109/TIE.2017.2674630, 2017.
[13] J. Y. C. Chan, N. C. F. Tse, L. L. Lai, "A coreless electric current sensor with circular conductor positioning calibration," IEEE Sensors Journal, vol. 62 no. 11, pp. 2922-2928, 2013.
[14] D. Wang, C. Nordman, J. M. Daughton, Z. Qian, J. Fink, "70% TMR at room temperature for SDT sandwich junctions with CoFeB as free and reference layers," IEEE Transactions on Magnetics, vol. 40 no. 4, pp. 2269-2271, DOI: 10.1109/TMAG.2004.830219, 2004.
[15] G. Feng, S. Van Dijken, J. F. Feng, J. M. Coey, T. Leo, D. J. Smith, "Annealing of CoFeB/MgO based single and double barrier magnetic tunnel junctions: tunnel magnetoresistance, bias dependence, and output voltage," Journal of Applied Physics, vol. 105 no. 3, 2009.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Copyright © 2021 X. P. Xu et al. This is an open access article distributed under the Creative Commons Attribution License (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License. https://creativecommons.org/licenses/by/4.0/
Abstract
In recent years, new energy vehicles, photovoltaic power stations, communication base stations, energy storage systems, and other power electronic systems have developed rapidly. The development of these systems has the trend of continuously increasing the power density per unit area, reducing the system volume, and continuously increasing using the busbars. More and more new current sensors will be used in these systems and play a key role. Traditional current sensor cannot meet the development trend of power electronic systems due to their large size and high cost. In this paper, a new small coreless tunnel junction magnetoresistance (TMR) busbar dc current sensor adopted differential scheme which improves the sensor’s anti-interference ability that is designed. The current sensor adopts an open-closed structure for easy nonintrusive installation. Four TMRs which adopted differential structure are placed on the edges of the busbar. The peak current measurement range is ±600 A, the rated current measurement range is ±300 A, and the supply voltage is 5 V.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer