It appears you don't have support to open PDFs in this web browser. To view this file, Open with your PDF reader
Abstract
Background
Successful breast cancer screening relies on timely follow-up of abnormal mammograms. Delayed or failure to follow-up abnormal mammograms undermines the potential benefits of screening and is associated with poorer outcomes. However, a comprehensive review of inadequate follow-up of abnormal mammograms in primary care has not previously been reported in the literature. This review could identify modifiable factors that influence follow-up, which if addressed, may lead to improved follow-up and patient outcomes.
Methods
A systematic literature review to determine the extent of inadequate follow-up of abnormal screening mammograms in primary care and identify factors impacting on follow-up was conducted. Relevant studies published between 1 January, 1990 and 29 October, 2020 were identified by searching MEDLINE®, Embase, CINAHL® and Cochrane Library, including reference and citation checking. Joanna Briggs Institute Critical Appraisal Checklists were used to assess the risk of bias of included studies according to study design.
Results
Eighteen publications reporting on 17 studies met inclusion criteria; 16 quantitative and two qualitative studies. All studies were conducted in the United States, except one study from the Netherlands. Failure to follow-up abnormal screening mammograms within 3 and at 6 months ranged from 7.2–33% and 27.3–71.6%, respectively. Women of ethnic minority and lower education attainment were more likely to have inadequate follow-up. Factors influencing follow-up included physician-patient miscommunication, information overload created by automated alerts, the absence of adequate retrieval systems to access patient’s results and a lack of coordination of patient records. Logistical barriers to follow-up included inconvenient clinic hours and inconsistent primary care providers. Patient navigation and case management with increased patient education and counselling by physicians was demonstrated to improve follow-up.
Conclusions
Follow-up of abnormal mammograms in primary care is suboptimal. However, interventions addressing amendable factors that negatively impact on follow-up have the potential to improve follow-up, especially for populations of women at risk of inadequate follow-up.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer