It appears you don't have support to open PDFs in this web browser. To view this file, Open with your PDF reader
Abstract
Fuchs uveitis (FU) is a chronic and often unilateral ocular inflammation and characteristic iris atrophic changes, other than heterochromia, are common in FU and are key to the correct diagnosis in many cases. With the advent of anterior segment optical coherence tomography (AS-OCT), some investigators attempted to quantitatively study these atrophic changes; mostly by introducing various methods to measure iris thickness in AS-OCT images. We aimed to present an automated method in an observational case series to measure the smoothness index (SI) of the iris surface in AS-OCT images. The ratio of the length of the straight line connecting the most peripheral and central points of the anterior iris border (in nasal and temporal sides) to the actual length of this border on AS-OCT images, was defined as SI. In a uveitis referral center, twenty-two eyes of 11 patients with unilateral Fuchs uveitis (FU) (7 female) and 22 eyes of 11 healthy control subjects underwent AS-OCT imaging. Image J and a newly developed MATLAB algorithm were used for manual and automated SI measurements, respectively. Agreement between manual and automated measurements was evaluated with Bland–Altman analysis and interclass correlation coefficient. The inter-eye difference of SI was compared between the FU group and the control group. Automated mean overall SI was 0.868 ± 0.037 and 0.840 ± 0.039 in FU and healthy fellow eyes, respectively (estimated mean difference = − 0.028, 95% CI [− 0.038, − 0.018], p < 0.001). Bland- Altman plots showed good agreement between two methods in both healthy and FU eyes. The interclass correlation coefficient between the manual and automated measurements in the FU and healthy fellow eyes was 0.958 and 0.964, respectively. The inter-eye difference of overall SI was 0.029 ± 0.015 and 0.012 ± 0.008 in FU group and control group, respectively (p = 0.01). We concluded that the automated algorithm can rapidly and conveniently measure SI with results comparable to the manual method.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details
1 Tehran University of Medical Sciences, Retina Service, Farabi Eye Hospital, Tehran, Iran (GRID:grid.411705.6) (ISNI:0000 0001 0166 0922)
2 Tehran University of Medical Sciences and Research Center for Science and Technology in Medicine, Department of Medical Physics and Biomedical Engineering, Tehran, Iran (GRID:grid.411705.6) (ISNI:0000 0001 0166 0922)
3 Tehran University of Medical Sciences, Department of Epidemiology and Biostatistics, School of Public Health, Tehran, Iran (GRID:grid.411705.6) (ISNI:0000 0001 0166 0922)