It appears you don't have support to open PDFs in this web browser. To view this file, Open with your PDF reader
Abstract
In several biomedical applications, the detection of biomarkers demands high sensitivity, selectivity and easy-to-use devices. Organic electrochemical transistors (OECTs) represent a promising class of devices combining a minimal invasiveness and good signal transduction. However, OECTs lack of intrinsic selectivity that should be implemented by specific approaches to make them well suitable for biomedical applications. Here, we report on a biosensor in which selectivity and a high sensitivity are achieved by interfacing, in an OECT architecture, a novel gate electrode based on aptamers, Au nanoparticles and graphene hierarchically organized to optimize the final response. The fabricated biosensor performs state of the art limit of detection monitoring biomolecules, such as thrombin-with a limit of detection in the picomolar range (≤ 5 pM) and a very good selectivity even in presence of supraphysiological concentrations of Bovine Serum Albumin (BSA-1mM). These accomplishments are the final result of the gate hierarchic structure that reduces sterich indrance that could contrast the recognition events and minimizes false positive, because of the low affinity of graphene towards the physiological environment. Since our approach can be easily applied to a large variety of different biomarkers, we envisage a relevant potential for a large series of different biomedical applications.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details
1 IMEM - CNR Institute of Materials for Electronics and Magnetism, Parma, Italy (GRID:grid.473331.1) (ISNI:0000 0004 1789 9243); University of Parma, Physics Department and Ph.D. School on Material Science and Technology, Parma, Italy (GRID:grid.10383.39) (ISNI:0000 0004 1758 0937)
2 IMEM - CNR Institute of Materials for Electronics and Magnetism, Parma, Italy (GRID:grid.473331.1) (ISNI:0000 0004 1789 9243)
3 University of Naples “Federico II”, Department of Chemical Sciences, Napoli, Italy (GRID:grid.4691.a) (ISNI:0000 0001 0790 385X)
4 IMEM - CNR Institute of Materials for Electronics and Magnetism, Parma, Italy (GRID:grid.473331.1) (ISNI:0000 0004 1789 9243); Politecnico di Torino, Chilab - Materials and Microsystems Laboratory, DISAT, Chivasso, Turin, Italy (GRID:grid.4800.c) (ISNI:0000 0004 1937 0343)
5 Politecnico di Torino, Chilab - Materials and Microsystems Laboratory, DISAT, Chivasso, Turin, Italy (GRID:grid.4800.c) (ISNI:0000 0004 1937 0343)
6 University of Trento, Department of Industrial Engineering, Trento, Italy (GRID:grid.11696.39) (ISNI:0000 0004 1937 0351); Indivenire s.r.l., Trento, Italy (GRID:grid.11696.39)
7 Trento Unit, IMEM - CNR Institute of Materials for Electronics and Magnetism, Trento, Italy (GRID:grid.11696.39)