© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Simple Summary

The aim of this study was to explore the usefulness of electrical impedance tomography (EIT), a novel monitoring tool measuring impedance change, to estimate tidal volume (volume of gas in litres moved in and out the airways and lungs with each breath) in anaesthetised horses. The results of this study, performed in clinical cases, demonstrated that there was a positive linear relationship between tidal volume measurements obtained with spirometry and impedance changes measured by EIT within each subject and this individual relationship could be used to estimate tidal volume that showed acceptable agreement with a measured tidal volume in each horse. Thus, EIT can be used to observe changes in tidal volume by the means of impedance changes. However, absolute measurement of tidal volume is only possible after establishment of the individual relationship.

Abstract

This study explores the application of electric impedance tomography (EIT) to estimate tidal volume (VT) by measuring impedance change per breath (∆Zbreath). Seventeen healthy horses were anaesthetised and mechanically ventilated for elective procedures requiring dorsal recumbency. Spirometric VT (VTSPIRO) and ∆Zbreath were recorded periodically; up to six times throughout anaesthesia. Part 1 assessed these variables at incremental delivered VT of 10, 12 and 15 mL/kg. Part 2 estimated VT (VTEIT) in litres from ∆Zbreath at three additional measurement points using a line of best fit obtained from Part 1. During part 2, VT was adjusted to maintain end-tidal carbon dioxide between 45–55 mmHg. Linear regression determined the correlation between VTSPIRO and ∆Zbreath (part 1). Estimated VTEIT was assessed for agreement with measured VTSPIRO using Bland Altman analysis (part 2). Marked variability in slope and intercepts was observed across horses. Strong positive correlation between ∆Zbreath and VTSPIRO was found in each horse (R2 0.9–0.99). The agreement between VTEIT and VTSPIRO was good with bias (LOA) of 0.26 (−0.36–0.88) L. These results suggest that, in anaesthetised horses, EIT can be used to monitor and estimate VT after establishing the individual relationship between these variables.

Details

Title
Use of Electrical Impedance Tomography (EIT) to Estimate Tidal Volume in Anaesthetized Horses Undergoing Elective Surgery
Author
Crivellari, Benedetta 1   VIAFID ORCID Logo  ; Raisis, Anthea 1   VIAFID ORCID Logo  ; Hosgood, Giselle 1 ; Waldmann, Andreas D 2 ; Murphy, David 1 ; Mosing, Martina 1 

 School of Veterinary Medicine, Murdoch University, Murdoch 6150, Australia; [email protected] (B.C.); [email protected] (A.R.); [email protected] (G.H.); [email protected] (D.M.) 
 Department of Anesthesiology and Intensive Care Medicine, Rostock University Medical Center, 39071 Rostock, Germany; [email protected] 
First page
1350
Publication year
2021
Publication date
2021
Publisher
MDPI AG
e-ISSN
20762615
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2531383670
Copyright
© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.