Abstract
Wall Shear Stress (WSS) has been demonstrated to be a biomarker of the development of atherosclerosis. In vivo assessment of WSS is still challenging, but 4D Flow MRI represents a promising tool to provide 3D velocity data from which WSS can be calculated. In this study, a system based on Laser Doppler Velocimetry (LDV) was developed to validate new improvements of 4D Flow MRI acquisitions and derived WSS computing. A hydraulic circuit was manufactured to allow both 4D Flow MRI and LDV velocity measurements. WSS profiles were calculated with one 2D and one 3D method. Results indicated an excellent agreement between MRI and LDV velocity data, and thus the set-up enabled the evaluation of the improved performances of 3D with respect to the 2D-WSS computation method. To provide a concrete example of the efficacy of this method, the influence of the spatial resolution of MRI data on derived 3D-WSS profiles was investigated. This investigation showed that, with acquisition times compatible with standard clinical conditions, a refined MRI resolution does not improve WSS assessment, if the impact of noise is unreduced. This study represents a reliable basis to validate with LDV WSS calculation methods based on 4D Flow MRI.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details
1 LHEEA Lab, École Centrale Nantes, CNRS UMR 6598, Nantes, France (GRID:grid.16068.39) (ISNI:0000 0001 2203 9289); Université de Nantes, CHU Nantes, CNRS UMR 6291, INSERM UMR 1087, L’institut du thorax, Nantes, France (GRID:grid.277151.7) (ISNI:0000 0004 0472 0371)
2 LS2N, École Centrale Nantes, CNRS UMR 6004, Nantes, France (GRID:grid.503212.7)
3 Université de Nantes, CHU Nantes, CNRS UMR 6291, INSERM UMR 1087, L’institut du thorax, Nantes, France (GRID:grid.277151.7) (ISNI:0000 0004 0472 0371); Université de Nantes, CHU Nantes, CNRS UMS 3556, INSERM UMS 016, SFR Santé, Nantes, France (GRID:grid.4817.a)
4 LHEEA Lab, École Centrale Nantes, CNRS UMR 6598, Nantes, France (GRID:grid.16068.39) (ISNI:0000 0001 2203 9289)
5 Université de Nantes, CHU Nantes, CNRS UMR 6291, INSERM UMR 1087, L’institut du thorax, Nantes, France (GRID:grid.277151.7) (ISNI:0000 0004 0472 0371)