Full Text

Turn on search term navigation

© 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Simple Summary

The feasibility and reliability of measurements of maximal short-term power (Pmax) and corresponding optimal movement velocity (υopt) with a friction-loaded cycle ergometer have not been systematically assessed in older subjects and those with diseases. In the present study, all the tests of relative and absolute reliability indicated very good repeatability and low indices of error. Our results show that a friction-loaded cycle ergometer instrumented with a strain gauge and an incremental encoder may be an excellent candidate for future clinical studies in older subjects and those with diseases.

Abstract

This study aimed to assess the feasibility and reliability of quadriceps maximal short-term power (Pmax) and corresponding optimal movement velocity (υopt—velocity at which the power reaches a maximum value) measurements in different populations of subjects. Five groups of subjects, fifty participants in each group, took part in the study: students; patients of the cardiac rehabilitation program; patients after stroke; older adults; and subjects of different ages who performed repetitive measurements with two different bicycles. The correlations calculated for the pairs of scores ranged from 0.93 to 0.99 for Pmax and from 0.86 to 0.96 for υopt (all with p < 0.001). Intraclass Correlations Coefficients (ICCs) varied from 0.93 to 0.98 for Pmax and from 0.86 to 0.95 for υopt. The standard error of measurement (SEM) varied from 16.9 to 21.4 W for Pmax and from 2.91 to 5.54 rotations(rot)/min for υopt. The coefficients of variation (CVs or SEM%) for Pmax and υopt in the stroke group were 10.6% and 11.4%, respectively; all other CVs were clearly lower than 10%. The minimal detectable change (MDC) varied from 46.6 to 59.3 W for Pmax and from 8.07 to 15.4 rot/min for υopt. MDC% varied from 9.53% to 29.3% for Pmax and from 8.19% to 31.7% for υopt, and was the highest in the stroke group. Therefore, the precision of measurements of Pmax and υopt was confirmed by very good indices of absolute and relative reliability. The proposed methodology is precise, safe, not time-consuming and feasible in older subjects and those with diseases.

Details

Title
Feasibility and Reliability of Quadriceps Muscle Power and Optimal Movement Velocity Measurements in Different Populations of Subjects
Author
Kostka, Tomasz 1   VIAFID ORCID Logo  ; Kostka, Joanna 2   VIAFID ORCID Logo 

 Department of Geriatrics, Medical University of Lodz, Plac Hallera 1, 90-647 Łódź, Poland 
 Department of Gerontology, Medical University of Lodz, Milionowa 14, 93-113 Łódź, Poland; [email protected] 
First page
140
Publication year
2024
Publication date
2024
Publisher
MDPI AG
e-ISSN
20797737
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2997630031
Copyright
© 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.