We describe herein a system of self-magnetically insulated vacuum transmission lines (MITLs) that operated successfully at 20 MA, 3 MV, and 55 TW. The system delivered the electromagnetic-power pulse generated by the Z accelerator to a physics-package load on over 1700 Z shots. The system included four levels that were electrically in parallel. Each level consisted of a water flare, vacuum-insulator stack, vacuum flare, and 1.3-m-radius conical outer MITL. The outputs of the four outer MITLs were connected in parallel by a 7.6-cm-radius 12-post double-post-hole vacuum convolute. The convolute added the currents of the four outer MITLs, and delivered the combined current to a single 6-cm-long inner MITL. The inner MITL delivered the current to the load. The total initial inductance of the stack-MITL system was 11 nH. A 300-element transmission-line-circuit model of the system has been developed using the tl code. The model accounts for the following: (i) impedance and electrical length of each of the 300 circuit elements, (ii) electron emission from MITL-cathode surfaces wherever the electric field has previously exceeded a constant threshold value, (iii) Child-Langmuir electron loss in the MITLs before magnetic insulation is established, (iv) MITL-flow-electron loss after insulation, assuming either collisionless or collisional electron flow, (v) MITL-gap closure, (vi) energy loss to MITL conductors operated at high lineal current densities, (vii) time-dependent self-consistent inductance of an imploding z -pinch load, and (viii) load resistance, which is assumed to be constant. Simulations performed with the tl model demonstrate that the nominal geometric outer-MITL-system impedance that optimizes overall performance is a factor of ∼3 greater than the convolute-load impedance, which is consistent with an analytic model of an idealized MITL-load system. Power-flow measurements demonstrate that, until peak current, the Z stack-MITL system performed as expected. tl calculations of the peak electromagnetic power at the stack, stack energy, stack voltage, outer-MITL current, and load current, as well as the pinch-implosion time, agree with measurements to within 5%. After peak current, tl calculations and measurements diverge, which appears to be due in part to the idealized pinch model assumed by tl. The results presented suggest that the design of the Z accelerator’s stack-MITL system, and the tl model, can serve as starting points for the design of stack-MITL systems of future superpower accelerators.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer