© 2017 Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted. This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Objective

To determine the inter-observer agreement of a respiratory rate (RR) count on a child when assessed by three independent observers.

Design

The RR of 169 children (age range: 3 days to 15 years) was measured by three independent observers over a 3-month period. The first RR was taken by different healthcare professionals (HCPs) from within the hospital using their own preferred method of measurement. A further count of RR was then taken by two observers from the research team simultaneously within 30 min of the first measurement, using the WHO-recommended method of measurement.

Results

507 RR measurements were taken on 169 children. Median RR showed a 4 beats per minute (bpm) difference between the HCP (median RR 32 bpm) and the researchers (median RR 28 bpm). The 95% limits of agreement between the first measurement and second and third measurements were −10.2 to 17.7 bpm and −11.4 to 18.7 bpm, respectively. For simultaneous measurements, the 95% limits of agreement were −7.1 to 7.0 bpm. 81 children had a RR >95th centile for their age and an even poorer level of agreement was seen in these children than in those whose RR was within normal range. In only 27 of these 81 children (33%) did all three observers agree on the presence of a raised RR.

Conclusions

Inter-observer agreement for the measurement of RR in children is poor. The effect that this variation has on the clinical assessment and subsequent management of a child may be significant. These findings highlight the need for a robust review of our current measurement methods and interpretation of an important vital sign.

Details

Title
Poor inter-observer agreement in the measurement of respiratory rate in children: a prospective observational study
Author
Daw, William James 1 ; Kingshott, Ruth N 1 ; Elphick, Heather E 1 

 Department of Respiratory Medicine, Sheffield Childen’s Hospital, Sheffield, UK; Academic Unit of Child Health, Sheffield Children’s Hospital, Sheffield, UK 
Section
General Paediatrics
Publication year
2017
Publication date
Nov 2017
Publisher
BMJ Publishing Group LTD
e-ISSN
23999772
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2552743443
Copyright
© 2017 Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted. This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.