© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Hand held dynamometers (HHDs) are the most used method to measure strength in clinical sitting. There are two methods to realize the assessment: pull and push. The purpose of the present study was to evaluate the intra- and inter-rater reliability of a new measurement modality for pull HHD and to compare the inter-rater reliability and agreement of the measurements. Forty healthy subjects were evaluated by two assessors with different body composition and manual strength. Fifteen isometric tests were performed in two sessions with a one-week interval between them. Reliability was examined using the intra-class correlation (ICC) and the standard error of measurement (SEM). Agreement between raters was examined using paired t-tests. Intra- and inter-rater reliability for the tests performed with the pull HHD showed excellent values, with ICCs ranging from 0.991 to 0.998. For tests with values higher than 200 N, push HHD showed greater differences between raters than pull HHD. Pull HHD attached to the examiner’s body is a method with excellent reliability to measure isometric strength and showed better agreement between examiners, especially for those tests that showed high levels of strength. Pull HHD is a new alternative to perform isometric tests with less rater dependence.

Details

Title
Intra- and Inter-Rater Reliability of Strength Measurements Using a Pull Hand-Held Dynamometer Fixed to the Examiner’s Body and Comparison with Push Dynamometry
Author
González-Rosalén, Javier 1   VIAFID ORCID Logo  ; Josep Carles Benítez-Martínez 1   VIAFID ORCID Logo  ; Medina-Mirapeix, Francesc 2 ; Alba Cuerda-Del Pino 1 ; Cervelló, Antonio 3   VIAFID ORCID Logo  ; Rodrigo Martín-San Agustín 1   VIAFID ORCID Logo 

 Department of Physiotherapy, University of Valencia, CP 46010 Valencia, Spain; [email protected] (J.G.-R.); [email protected] (A.C.-D.P.); [email protected] (R.M.-S.A.) 
 Department of Physiotherapy, University of Murcia, CP 30100 Murcia, Spain; [email protected] 
 Department of Electronic Engineering, University of Valencia, CP 46100 Valencia, Spain; [email protected] 
First page
1230
Publication year
2021
Publication date
2021
Publisher
MDPI AG
e-ISSN
20754418
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2554488015
Copyright
© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.