Full text

Turn on search term navigation

© 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Background: The aim of this study was to compare the validity and reliability of a PUSH band device with a linear encoder to measure movement velocity with different loads during the push-up and bench press exercises. Methods: Twenty resistance-trained athletes performed push-up and bench press exercises with four different loads: without weight vest, 10-20-30 kg weight vest, bench press: 50–82% of their assumed 1 repetition maximum (1 RM) in steps of 10 kg. A linear encoder (Musclelab) and the PUSH band measured mean and peak velocity during both exercises. Several statistical analyses were used to investigate the validity and reliability of the PUSH band with the linear encoder. Results: The main findings of this study demonstrated only moderate associations between the PUSH band and linear encoder for mean velocity (r = 0.62, 0.70) and peak velocity (r = 0.46, 0.49) for both exercises. Furthermore, a good level of agreement (peak velocity: ICC = 0.60, 0.64; mean velocity: ICC = 0.77, 0.78) was observed between the two measurement devices. However, a significant bias was found with lower velocity values measured with the PUSH band in both exercises. In the push-up, both the linear encoder and PUSH band were deemed very reliable (ICC > 0.98; the coefficient of variation (CV): 5.9–7.3%). Bench press reliability decreased for the PUSH band (ICC < 0.95), and the coefficient of variance increased to (12.8–13.3%) for the velocity measures. Calculated 1 RM with the two devices was the same for the push-up, while in bench press the PUSH band under-estimated the 1 RM by 14 kg compared to the linear encoder. Conclusions: It was concluded that the PUSH band will show decreased reliability from velocity measures in a bench press exercise and underestimate load-velocity based 1 RM predictions. For training, the PUSH band can be used during push-ups, however caution is suggested when using the device for the purposes of feedback in bench press at increasing loads.

Details

Title
Validity and Reliability of Kinematics Measured with PUSH Band vs. Linear Encoder in Bench Press and Push-Ups
Author
van den Tillaar, Roland 1 ; Ball, Nick 2 

 Department of Sport Sciences and Physical Education, Nord University, 7601 Levanger, Norway 
 Faculty of Health, Research Institute for Sport and Exercise Science, University of Canberra, Canberra 2601, Australia 
First page
207
Publication year
2019
Publication date
2019
Publisher
MDPI AG
e-ISSN
20754663
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2558088853
Copyright
© 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.