Abstract

The object of this work was to determine the icing temperature in icing experiment. Firstly, a questionnaire investigation was carried out on 38 fire detachments in different regions. These Statistical percentage results were divided into northern east group and northern west group. Secondly, a significance analysis between these two results was made using Mann-Whitney U test. Then the icing temperature was determined in different regions. Thirdly, the icing experiment was made in the environment of -20°C in Daxing’an Mountain. The anti-icing effect of new fire protective clothing was verified in this icing.

Details

Title
Significance analysis of the regional differences on icing time of water onto fire protective clothing
Author
Zhao, L Z 1 ; Jing, L S 1 ; Zhang, X Z 1 ; Xia, J J 1 ; Chen, Y 1 ; Chen, T 1 ; C Hu 1 ; Bao, Z M 1 ; Fu, X C 1 ; Wang, R J 1 ; Wang, Y 1 ; Wang, Y J 2 

 Tianjin Fire Research Institute of MPS, Tianjin, China 
 Daxing’an Mountain Fire Detachment, Heilongjiang, China 
Publication year
2017
Publication date
Sep 2017
Publisher
IOP Publishing
ISSN
17578981
e-ISSN
1757899X
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2564116952
Copyright
© 2017. This work is published under http://creativecommons.org/licenses/by/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.