Dual-comb spectroscopy (DCS) offers high sensitivity and wide spectral coverage without the need for bulky spectrometers or mechanical moving parts. And DCS in the mid-infrared (mid-IR) is of keen interest because of inherently strong molecular spectroscopic signatures in these bands. We report GHz-resolution mid-IR DCS of methane and ethane that is derived from counter-propagating (CP) soliton microcombs in combination with interleaved difference frequency generation. Because all four combs required to generate the two mid-IR combs rely upon stability derived from a single high-Q microcavity, the system architecture is both simplified and does not require external frequency locking. Methane and ethane spectra are measured over intervals as short as 0.5 ms, a time scale that can be further reduced using a different CP soliton arrangement. Also, tuning of spectral resolution on demand is demonstrated. Although at an early phase of development, the results are a step towards mid-IR gas sensors with chip-based architectures for chemical threat detection, breath analysis, combustion studies, and outdoor observation of trace gases.
Chip-based architectures for mid-infrared gas sensing could enable many applications. In this direction, the authors demonstrate a microcomb-based dual-comb spectroscopy sensor with GHz resolution in the mid-IR band, with stability completely determined by a single high-Q microresonator.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details



1 California Institute of Technology, T. J. Watson Laboratory of Applied Physics, Pasadena, USA (GRID:grid.20861.3d) (ISNI:0000000107068890); Tsinghua University, State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instruments, Beijing, China (GRID:grid.12527.33) (ISNI:0000 0001 0662 3178)
2 California Institute of Technology, T. J. Watson Laboratory of Applied Physics, Pasadena, USA (GRID:grid.20861.3d) (ISNI:0000000107068890)
3 California Institute of Technology, T. J. Watson Laboratory of Applied Physics, Pasadena, USA (GRID:grid.20861.3d) (ISNI:0000000107068890); NTT Research, Physics & Informatics Laboratories, Sunnyvale, USA (GRID:grid.511349.b)
4 University of Rochester, Department of Electrical and Computer Engineering, Rochester, USA (GRID:grid.16416.34) (ISNI:0000 0004 1936 9174)