Full text

Turn on search term navigation

© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Background: With the advent of implantable cardioverter-defibrillator (ICD) technology in recent decades, patients with inherited or congenital cardiomyopathy have a greater chance of survival into adulthood. Women with ICDs in this group are now more likely to reach reproductive age. However, pregnancy represents a challenge for clinicians, as no guidelines for the treatment of pregnant women with an ICD are currently available. Methods: To analyze this issue, we performed a systematic screening of the literature using the keywords: pregnancy with ICD, lead fracture in pregnancy, lead thrombi in pregnancy, ventricular tachycardia in pregnancy, inappropriate shocks in pregnancy, ICD discharge in pregnancy and ICD shock in pregnancy. Of 1101 publications found, 27 publications were eligible for further analysis (four retrospective trials and 23 case reports). Results: According to physiological changes in pregnancy, resulting in an increase in heart rate and cardiac output, a vulnerability for malignant arrhythmias and device-related complications in ICD carriers might be suspected. While the literature is limited on this issue, maternal complications including arrhythmia burden with following ICD therapies, thromboembolic events and lead complications as well as inappropriate shock therapy have been reported. According to the limited available studies, associated risk seems not to be more frequent than in the general population and depends on the underlying cardiac pathology. Furthermore, worsening of heart failure and related cardiovascular disease have been reported with associated risk of preterm delivery. These observations are exaggerated by restricted applications of diagnostics and treatment due to the risk of fetal harm in this population. Conclusions: Due to limited data on management of ICDs during pregnancy, further scientific investigations are required. Consequently, careful risk assessment with individual risk evaluation and close follow ups with interdisciplinary treatment are recommended in pregnant ICD carriers.

Details

Title
Management of Implantable Cardioverter-Defibrillators during Pregnancy—A Systematic Review
Author
Topf, Albert 1 ; Bacher, Nina 1 ; Kopp, Kristen 1 ; Moritz Mirna 1   VIAFID ORCID Logo  ; Larbig, Robert 2 ; Brandt, Mathias C 1 ; Kraus, Johannes 1 ; Hoppe, Uta C 1 ; Motloch, Lukas J 1 ; Lichtenauer, Michael 1 

 Department of Internal Medicine II, Paracelsus Medical University Salzburg, 5020 Salzburg, Austria; [email protected] (N.B.); [email protected] (K.K.); [email protected] (M.M.); [email protected] (M.C.B.); [email protected] (J.K.); [email protected] (U.C.H.); [email protected] (L.J.M.); [email protected] (M.L.) 
 Division of Cardiology, Hospital Maria Hilf Mönchengladbach, 41063 Mönchengladbach, Germany; [email protected]; Division of Electrophysiology, Department of Cardiovascular Medicine, University of Münster, 48149 Münster, Germany 
First page
1675
Publication year
2021
Publication date
2021
Publisher
MDPI AG
e-ISSN
20770383
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2599063332
Copyright
© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.