© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Simple Summary

Nonischemic cardiomyopathies with low left ventricular ejection fractions (LVEF) are eligible for an implantable cardioverter defibrillator. However, the guidelines do not specify which method should be used to assess LVEF. In our study we investigated the potential impact of performing two-dimensional echocardiography (2DE) compared to cardiovascular magnetic resonance (CMR) for LVEF regarding ICD eligibility. We found that 2DE both overestimated and especially underestimated the need for implantation, which can have serious implications in the quality of life and the prevention of death events.

Abstract

Background: The aim of this study was to investigate the potential impact of performing two-dimensional echocardiography (2DE) compared to cardiovascular magnetic resonance (CMR) for left ventricular ejection fraction (LVEF) on implantable cardioverter defibrillator (ICD) eligibility. Methods: A prospective cohort of 166 consecutive patients with nonischemic cardiomyopathy (NICM) was designed to compare transthoracic 2DE and CMR imaging. Results: Echocardiography measurements have important differences and large limits of agreement compared to CMR, especially when assessing ventricle volumes, and smaller but relevant differences when assessing LVEF. The agreement between CMR and 2DE regarding the identification of subjects with EF <= 35, respectively <= 30, and thus eligible for an ICD measured by Cohen’s Kappa was 0.78 (95% CI: 0.68–0.88), p < 0.001, respectively 0.65 (95% CI: 0.52–0.78), p < 0.001. The disagreement represented 7.9%/11.3% of the subjects who had EF < 35%/< 30% as observed by CMR, who would have been classified as eligible for an ICD, resulting in an additional need to use an ICD. Moreover, 2.6%/3.3% would have been deemed eligible by echocardiography for an ICD. Conclusions: These measurement problems result in incorrect assignments of eligibility that may have serious implications on the quality of life and the prevention of death events for patients assessed for eligibility of an ICD.

Details

Title
Magnetic Resonance Assessment of Ejection Fraction Versus Echocardiography for Cardioverter-Defibrillator Implantation Eligibility
Author
Schiau, Călin 1 ; Daniel-Corneliu Leucuța 2   VIAFID ORCID Logo  ; Sorin, Marian Dudea 1 ; Manole, Simona 1 

 Department of Radiology, “Iuliu Hatieganu” University of Medicine and Pharmacy, 400006 Cluj-Napoca, Romania; [email protected] (C.S.); [email protected] (S.M.D.); [email protected] (S.M.) 
 Department of Medical Informatics and Biostatistics, “Iuliu Hatieganu” University of Medicine and Pharmacy, 400349 Cluj-Napoca, Romania 
First page
1108
Publication year
2021
Publication date
2021
Publisher
MDPI AG
e-ISSN
20797737
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2602013043
Copyright
© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.