© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Background: The treatment of relapsed or refractory leukemia remains a major problem. Among the new therapeutic approaches, the use of modified T lymphocytes, called chimeric antigen receptor T cells (CAR-T cells), seems promising. The first step of their preparation is leukapheresis, which involves the collection of mononuclear cells from the patient. This medical procedure requires numerous medical devices (MDs) made of plasticized polyvinylchloride (PVC). These compounds can leach out of the devices during contact with the patient’s blood. The aim of our study was to evaluate the migration of the plasticizers contained in the MD during a simulated pre-CAR-T cell leukapheresis procedure, and to measure the patient’s and their lymphocytes’ exposure to them. Methods: The qualitative and quantitative composition of the MD used for pre-CAR-T cell apheresis was determined by gas chromatography–mass spectrometry (GC–MS). Then, an ex vivo leukapheresis model using an ethanol/water simulant was performed to evaluate the plasticizers’ migration under simulated clinical conditions of pre-CAR-T cells’ cytapheresis. The plasticizers released into the simulant were quantified by GC–MS. Results: Diethylhexylphthalate (DEHP) was found in the apheresis kit, with amounts ranging from 25% to 59% (g/100 g of PVC). Bis(2-ethylhexyl) adipate was detected at trace levels. A total of 98.90 ± 11.42 mg of DEHP was released into the simulant, corresponding to an exposure dose of 1.4 mg/kg for a 70 kg patient. Conclusions: Patients undergoing a pre-CAR-T cell apheresis are mainly exposed to DEHP, which can impact their health because of its endocrine disruption effect, but could also lead to a decrease in CAR-T cells’ efficiency/quality.

Details

Title
Ex Vivo Model to Assess the Exposure of Patients to Plasticizers from Medical Devices during Pre-CAR-T Cells’ Apheresis
Author
Lautraite, Raphaëlle 1 ; Bernard, Lise 1   VIAFID ORCID Logo  ; Halle, Pascale 2 ; Chennell, Philip 1   VIAFID ORCID Logo  ; Yoann Le Basle 1   VIAFID ORCID Logo  ; Kanold, Justyna 3 ; Sautou, Valérie 1   VIAFID ORCID Logo 

 Université Clermont Auvergne, CHU Clermont Ferrand, Clermont Auvergne INP, CNRS, ICCF, F-63000 Clermont-Ferrand, France; [email protected] (R.L.); [email protected] (P.C.); [email protected] (Y.L.B.); [email protected] (V.S.) 
 CHU Clermont-Ferrand, Centre de Biothérapie d’Auvergne, F-63000 Clermont-Ferrand, France; [email protected] (P.H.); [email protected] (J.K.) 
 CHU Clermont-Ferrand, Centre de Biothérapie d’Auvergne, F-63000 Clermont-Ferrand, France; [email protected] (P.H.); [email protected] (J.K.); Université Clermont Auvergne, CHU Clermont-Ferrand, INSERM CIC 1405 Unité CRECHE, F-63000 Clermont–Ferrand, France 
First page
79
Publication year
2022
Publication date
2022
Publisher
MDPI AG
e-ISSN
23056304
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2633196047
Copyright
© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.