Full Text

Turn on search term navigation

© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Traditional dental implant navigation systems (DINS) based on binocular stereo vision (BSV) have limitations, for example, weak anti-occlusion abilities, as well as problems with feature point mismatching. These shortcomings limit the operators’ operation scope, and the instruments may even cause damage to the adjacent important blood vessels, nerves, and other anatomical structures. Trinocular stereo vision (TSV) is introduced to DINS to improve the accuracy and safety of dental implants in this study. High positioning accuracy is provided by adding cameras. When one of the cameras is blocked, spatial positioning can still be achieved, and doctors can adjust to system tips; thus, the continuity and safety of the surgery is significantly improved. Some key technologies of DINS have also been updated. A bipolar line constraint algorithm based on TSV is proposed to eliminate the feature point mismatching problem. A reference template with active optical markers attached to the jaw measures head movement. A T-type template with active optical markers is used to obtain the position and direction of surgery instruments. The calibration algorithms of endpoint, axis, and drill are proposed for 3D display of the surgical instrument in real time. With the preoperative path planning of implant navigation software, implant surgery can be carried out. Phantom experiments are carried out based on the system to assess the feasibility and accuracy. The results show that the mean entry deviation, exit deviation, and angle deviation are 0.55 mm, 0.88 mm, and 2.23 degrees, respectively.

Details

Title
Dental Implant Navigation System Based on Trinocular Stereo Vision
Author
Bi, Songlin 1   VIAFID ORCID Logo  ; Wang, Menghao 1 ; Zou, Jiaqi 1 ; Gu, Yonggang 2   VIAFID ORCID Logo  ; Zhai, Chao 2 ; Gong, Ming 2 

 Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei 230027, China; [email protected] (S.B.); [email protected] (M.W.); [email protected] (J.Z.) 
 Experiment Center of Engineering and Material Science, University of Science and Technology of China, Hefei 230027, China; [email protected] (Y.G.); [email protected] (M.G.) 
First page
2571
Publication year
2022
Publication date
2022
Publisher
MDPI AG
e-ISSN
14248220
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2649091877
Copyright
© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.