Abstract

The measurement of frequency characteristics, like magnitude and phase, related to a specific transfer function of DC–DC converters, can be a difficult task – especially when the measured signal approaches the boundary of a small-signal model validity (i:e. 1/3 of the switching frequency fS). It is hard to find a paper where authors mention the measurement techniques they use to draw frequency characteristics. Meanwhile the presence of noise in the output signal does not enable to directly measure the gain and the phase shift between the input and output signals. In such situations additional analysis is required in order to achieve a reliable result. This paper contains a description of a few methods that can be used to analyse measured signals in order to determine the gain and the phase shift of a specific transfer function. They enable to verify mathematical models in a wide range of frequencies (up to 1/3 fS). The methods use signals measured in the time domain and can be implemented in mathematical software such as Matlab or Scilab.

Details

Title
Methods of DC/DC converter transfer function measurements, based on data acquired in the time domain
Author
Walczak, Marcin
Pages
661-671
Publication year
2019
Publication date
2019
Publisher
Polish Academy of Sciences
ISSN
20809050
e-ISSN
23001941
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2650297512
Copyright
© 2019. This work is licensed under https://creativecommons.org/licenses/by-sa/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.